文献速递胸部介入CTDR

自体血封堵注射预防经胸肺活检后气胸的疗效

Efficacy of autologous blood patch injection for the prevention of pneumothorax after transthoracic lung biopsy.
PubMed 文献 · Clin Radiol · 2025-11-12

单中心回顾性研究纳入494例经胸CT引导肺活检患者,比较自体血封堵组245例与未封堵对照组249例。封堵组气胸发生率13.1%(32/245)低于对照组31.3%(78/249),需置入胸腔引流管者2.9%(7/245)低于对照组8.0%(20/249),结论认为不作特殊体位摆放的自体血封堵安全有效。

要点

  • 封堵组气胸发生率13.1%(32/245),对照组31.3%(78/249),P<.001。
  • 封堵组需胸腔引流管置入2.9%(7/245),对照组8.0%(20/249),P=.019。
  • 封堵组因气胸需二次胸片2.0%(5/245),对照组9.2%(23/249),P=.001。

核心结论

  • 经胸肺活检后以自体血封堵活检针道、不作特殊体位摆放,在预防气胸和胸腔引流管置入方面安全有效。

研究设计与样本

  • 单中心回顾性研究,封堵组(A组)245例为2024年2月1日至2025年1月31日连续接受经胸CT引导肺活检并自体血封堵注射的患者。
  • 对照组(B组)249例为2022年8月1日至2023年7月30日连续接受经胸CT引导肺活检且未行血封堵注射的患者,共纳入494例。

诊断标准与关键数值

  • A组245例中235例(95.9%)成功完成血封堵注射。
  • 气胸发生率:A组32/245(13.1%) vs B组78/249(31.3%),P<.001。
  • 需置入胸腔引流管比例:A组7/245(2.9%) vs B组20/249(8.0%),P=.019。
  • 因气胸需二次胸部X线检查比例:A组5/245(2.0%) vs B组23/249(9.2%),P=.001。

临床应用与阅片要点

  • 作者结论认为,经胸肺活检后以自体血封堵针道、不作特殊体位摆放,预防气胸和胸腔引流管置入安全有效。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: Transthoracic computed tomography (CT)-guided lung biopsy (TLB) is associated with a risk of pneumothorax. Most studies evaluating the efficacy of blood patch injection for preventing pneumothorax also combined patient positioning techniques, making it difficult to evaluate the sealing effect. This study aimed to assess the efficacy of autologous blood patch sealing without specific patient positioning technique after TLB for preventing pneumothorax and chest tube insertion.

MATERIAL AND METHODS: In our single institution, from February 1st, 2024, to January 31st, 2025, consecutive patients who underwent TLB with autologous blood patch injection were retrospectively compared with consecutive patients who underwent TLB from August 1st, 2022, to July 30th, 2023, with no blood patch injection.

RESULTS: A total of 494 patients were included, with 245 patients in the blood patch group (group A) and 249 patients in the control group (group B). Blood patch injection was successfully performed in 235 of 245 (95.9%) patients in group A. The rate of pneumothorax was 32 of 245 patients in group A (13.1%) vs 78 of 249 patients in group B (31.3%) (P < .001). Seven (2.9%) patients required chest tube insertion in group A vs 20 (8.0%) in group B (P = .019). Five (2.0%) patients required a secondary chest radiograph for pneumothorax in group A vs 23 (9.2%) in group B (P = .001).

CONCLUSION: Sealing the biopsy tract with an autologous blood patch after TLB, without a specific patient positioning technique is safe and effective in preventing pneumothorax and chest tube insertion.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Gravel G, Roussel A, Lampson PA, et al. Efficacy of autologous blood patch injection for the prevention of pneumothorax after transthoracic lung biopsy. Clin Radiol. 2025. PMID: 41401682. doi:10.1016/j.crad.2025.107177

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。