文献速递胸部MR

共轭梯度与深度学习重建:在不影响图像质量和结节检出的情况下缩短扫描时间

Conjugate gradient and deep learning reconstructions: reduced time without affecting image quality and nodule detection.
PubMed 文献 · Eur Radiol · 2025-12-24

在体模和35例肺结节患者中比较共轭梯度重建(CG Recon)联合或不联合深度学习重建(DLR)与网格重建(Grid Recon)的超短TE肺MRI。CG Recon和DLR可在缩短扫描时间的同时维持图像质量和结节检出能力,部分CG Recon方案AUC显著高于标准方案。

要点

  • CG Recon联合或不联合DLR可在减少辐条数、缩短扫描时间时维持肺结节检出能力。
  • 标准方案与各CG Recon及DLR方案的SNR均有显著差异(p<0.05)。
  • 标准方案与所有UTE1/4方案的总体图像质量有显著差异(p<0.05)。

核心结论

  • CG Recon和DLR可在肺UTE-MRI上缩短扫描时间,同时维持图像质量和结节检出能力。

研究设计与样本

  • 体外研究采用NEMA体模,体内研究纳入35例肺结节患者。
  • 采用UTE-MRI分别获取原始辐条数(TEoriginal)、1/2辐条数(UTE1/2)和1/4辐条数(UTE1/4),每种均经两种方法重建并有/无DLR。
  • 标准方案为Grid Recon无DLR的UTEoriginal。

关键影像表现/征象

  • 体外和体内研究中,标准方案与各CG Recon及DLR的UTE-MRI方案之间所有SNR均有显著差异(p<0.05)。
  • 标准方案与所有UTE1/4方案的总体图像质量有显著差异(p<0.05)。

诊断标准与关键数值

  • 各CG Recon获得的UTEOriginal方案AUC显著大于标准方案(p<0.05)。
  • 标准方案与各CG Recon及DLR方案的SNR差异均有统计学意义(p<0.05)。
  • 标准方案与所有UTE1/4方案的总体图像质量差异有统计学意义(p<0.05)。

临床应用与阅片要点

  • CG Recon联合或不联合DLR可在减少辐条数、缩短扫描时间时用于肺UTE-MRI并维持结节检出能力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to determine the utility of conjugate gradient reconstruction (CG Recon) and deep learning reconstruction (DLR) for reducing scan time while maintaining the image quality and nodule detection capability on lung MRI with ultrashort TE (UTE-MRI) as compared with grid reconstruction (Grid Recon).

MATERIALS AND METHODS: In the in vitro and in vivo studies, the NEMA phantom and 35 patients with pulmonary nodules were scanned by UTE-MRI with original (TEoriginal), 1/2 (UTE1/2), and 1/4 (UTE1/4) spoke numbers obtained by both methods and reconstructed with and without DLR. In this study, the standard protocol was UTEoriginal obtained by Grid Recon without DLR. Then, signal-to-noise ratios (SNR) of the phantom, lung and lesion were assessed. In the in vivo study, overall image quality and nodule detection capability were visually assessed on each UTE-MRI. Quantitative and qualitative indices were then compared between the standard protocol and others. Finally, a receiver operating characteristic (ROC) analysis was performed to compare the standard and other protocols.

RESULTS: In in vitro and in vivo studies, all SNRs were significantly different between the standard protocol and each UTE-MRI with CG Recon and DLR (p < 0.05). Overall image quality of the standard protocol differed significantly from that of all UTE1/4s (p < 0.05). The area under the curve of each UTEOriginal obtained by CG Recon was significantly larger than that of the standard protocol (p < 0.05).

CONCLUSION: CG Recon and DLR can reduce scan time while maintaining image quality and nodule detection capabilities on lung UTE-MRI.

KEY POINTS: Question To determine the utility of conjugate gradient reconstruction (CG Recon) to reduce scan time without nodule detection capability on MRI with ultrashort TE (UTE-MRI). Findings Nodule detection capability was not significantly decreased by CG Recon with or without deep learning reconstruction when reducing scan time from the standard UTE-MRI protocol. Clinical relevance Conjugate gradient reconstruction (CG Recon) and deep learning reconstruction (DLR) have the potential to reduce scan time while maintaining image quality and nodule detection capability in lung MR imaging with ultrashort TE.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ohno Y, Ozawa Y, Ueda T, et al. Conjugate gradient and deep learning reconstructions: reduced time without affecting image quality and nodule detection. Eur Radiol. 2025. PMID: 41444395. doi:10.1007/s00330-025-12153-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。