Pi10与PiSlope计算方法的比较及其与肺功能的相关性
本研究在CanCOLD队列1351名参与者中比较了10种文献来源的Pi10/PiSlope计算方法,发现纳入气道数量较多的计算方法可靠性更优(ICC>0.90,p<0.05),且PiSlope在所有方法中与FEV1、FEV1/FVC及FEF25-75%的负相关均强于Pi10。
要点
- 纳入气道数量较多的Pi10/PiSlope计算方法(Patel、Nakano、Smith、Jobst、Bhatt)可靠性优秀(ICC>0.90)。
- PiSlope在所有计算方法中与FEV1、FEV1/FVC、FEF25-75%的负相关均强于Pi10。
- 不同Pi10计算方法所得数值差异较大,跨研究比较时需注意方法学差异。
核心结论
- 纳入气道数量较多的Pi10/PiSlope计算方法可靠性更优,且PiSlope可能比Pi10更全面地反映COPD气道重塑。
研究设计与样本
- 基于CanCOLD参与者的研究,共纳入1351名参与者(67±10岁;550名女性),行全吸气相CT扫描,使用VIDA软件进行气道分割,采用10种文献来源方法计算Pi10(周长为10 mm时的回归推导壁厚)和PiSlope(壁面积/周长图的斜率),以组内相关系数评估可靠性、回归分析评估与肺功能的相关性。
诊断标准与关键数值
- 10种方法中部分聚焦特定气道尺寸(Patel、Van Tho、Nakano、Telenga),部分限定特定气道分级(Gietema、Park、Dudurych),部分覆盖更广气道尺寸范围和分级(Bhatt、Jobst、Smith);纳入气道数量较多的计算方法(Patel、Nakano、Smith、Jobst、Bhatt)ICC>0.90(p<0.05)。
临床应用与阅片要点
- 作者指出这些结果有助于判断哪些Pi10/PiSlope计算方法可产生更可靠的发现,并支持PiSlope作为监测COPD气道重塑的潜在可靠生物标志物。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The average wall thickness of a theoretical airway with a lumen perimeter of 10 mm (Pi10) and the slope of the luminal perimeter of airways against their wall thickness (PiSlope) are CT-derived biomarkers of airway remodeling in chronic obstructive pulmonary disease (COPD). However, numerous calculation methods for Pi10 have been used across studies, leading to substantial variability in Pi10 values. This study evaluated reliability among 10 Pi10/PiSlope methodologies and their associations with lung function.
MATERIALS AND METHODS: CanCOLD participants underwent full-inspiration CT scans; CT airway segmentation was performed using VIDA software. Ten literature-based methods were used to calculate Pi10 (regression-derived wall thickness at 10 mm perimeter) and PiSlope (slope of wall area/perimeter plot). The 10 methods varied in their approaches: some focused on specific airway sizes (Patel, Van Tho, Nakano, Telenga), others limited measurements to certain airway generations (Gietema, Park, Dudurych) or covered broader airway size ranges and generations (Bhatt, Jobst, Smith). Reliability was assessed via intraclass correlation (ICC); lung function associations were assessed using regression.
RESULTS: Pi10 and PiSlope were calculated for 1351 participants (67 ± 10 years; 550 women). Pi10 and PiSlope measurement methods with higher airway counts (Patel, Nakano, Smith, Jobst, Bhatt) showed excellent reliability (ICC > 0.90, p < 0.05). Compared to Pi10, PiSlope demonstrated stronger, consistent negative associations with FEV1, FEV1/FVC, and FEF25-75% across all methods, especially in those with fewer airways.
CONCLUSION: These results provide insight into which Pi10/PiSlope calculation methods may generate more reliable findings and indicate PiSlope may provide a more comprehensive measure of airway remodeling in COPD.
KEY POINTS: Question CT Pi10/PiSlope measures airway remodeling in COPD, but calculation methods vary. Are CT Pi10/PiSlope reliable and provide comparable associations with lung function across various methodologies? Findings Pi10/PiSlope calculation methods that included a higher number of CT airways were more reliable, and PiSlope showed stronger associations with lung function than Pi10. Clinical relevance These results provide insight into which methods may generate more reliable findings, aiding interpretation of results between studies, and support the potential of PiSlope as a reliable biomarker for monitoring airway remodeling in COPD.
引用
- Enjilela R, Virdee S, Bartlett J, et al. Comparison of Pi10 and PiSlope calculation methods and association with lung function. Eur Radiol. 2025. PMID: 41422440. doi:10.1007/s00330-025-12226-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。