动态胸部X线摄影作为慢性阻塞性肺疾病肺功能检查的替代方法
前瞻性单中心观察研究纳入553名参与者(191例COPD,362例对照),评估动态胸部X线摄影(DCR)参数与肺功能检查(PFT)指标的相关性及诊断效能。双侧深吸气时投影肺面积变化率(ΔPLA)与FEV1占预计值百分比(r=0.650)及FEV1/FVC(r=0.638)正相关;基于DCR参数和吸烟状态的列线图在内测试集AUC为0.85(95%CI:0.78,0.92),提示DCR可能是COPD筛查的有效替代方法。
要点
- DCR双侧深吸气ΔPLA与FEV1占预计值百分比正相关(r=0.650,P<.001)。
- DCR双侧深吸气ΔPLA诊断COPD内测试集AUC为0.78(95%CI:0.72,0.85)。
- 包含DCR参数和吸烟状态的联合模型内测试集AUC为0.85(95%CI:0.78,0.92)。
核心结论
- 基于DCR的列线图在识别COPD方面表现出稳健的诊断效能,提示DCR是标准PFT用于COPD筛查的有效替代方法。
研究设计与样本
- 前瞻性单中心观察研究,2022年11月至2024年7月纳入553名参与者(中位年龄60岁,IQR 53-67岁;男355例,女198例;COPD 191例,对照362例),采用Pearson相关、ROC分析、LASSO及多变量逻辑回归建模并在内测试集验证。
诊断标准与关键数值
- 在COPD参与者中,双侧深吸气ΔPLA与FEV1占预计值百分比相关(r=0.650,P<.001),与FEV1/FVC相关(r=0.638,P<.001);双侧深吸气ΔPLA内测试集AUC为0.78(95%CI:0.72,0.85);DCR模型内测试集AUC为0.82(95%CI:0.75,0.89);联合模型(DCR参数+吸烟状态)内测试集AUC为0.85(95%CI:0.78,0.92)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Pulmonary function tests (PFTs) are the clinical standard for diagnosing chronic obstructive pulmonary disease (COPD) but face limitations in accessibility and complexity. Dynamic chest radiography (DCR) is an emerging technique that enables dynamic pulmonary function assessment with low radiation exposure, suggesting potential as an alternative to PFTs. However, its diagnostic validity remains unproven. Purpose To determine whether DCR is an efficacious alternative approach to PFTs for COPD screening. Materials and Methods This prospective single-center observational study enrolled participants with or without COPD from November 2022 to July 2024. Correlations between DCR parameters and PFT indexes were assessed using Pearson correlation. Receiver operating characteristic analysis was used to evaluate diagnostic performance. The least absolute shrinkage and selection operator (LASSO) and multivariable logistic regression were used to select features and build and train predictive models, which were tested on an internal test set. A nomogram was used to visualize COPD probability, calibrated using the Hosmer-Lemeshow test. Results This study included 553 participants (median age, 60 years [IQR, 53-67 years]; 355 men; 198 women; 191 with COPD, 362 controls). DCR parameters were positively correlated with PFT indexes in participants with COPD: The combined bilateral (right and left lungs) rate of change in projected lung area (ΔPLA) during deep breathing was correlated with forced expiratory volume in 1 second (FEV1) percent predicted (r = 0.650; P < .001) and the ratio of FEV1 to forced vital capacity (r = 0.638; P < .001). The diagnostic performance of bilateral ΔPLA during deep breathing was high in the internal test set (area under the receiver operating characteristic curve [AUC], 0.78 [95% CI: 0.72, 0.85]). Three DCR features were selected to construct the DCR model, which performed well in the internal test set (AUC, 0.82 [95% CI: 0.75, 0.89]). The combined model incorporating a DCR parameter and smoking status demonstrated high diagnostic performance (internal test set: AUC, 0.85 [95% CI: 0.78, 0.92]). Conclusion A DCR-based nomogram demonstrated robust diagnostic performance in identifying COPD, suggesting that DCR represents an efficacious alternative approach to standard PFTs for COPD screening. ClinicalTrials.gov Identifier: NCT06653413 © The Author(s) 2025. Published by the Radiological Society of North America under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Hatabu et al in this issue.
引用
- Yu D, Xie W, Guo Y, et al. Dynamic Chest Radiography as an Alternative to Pulmonary Function Tests for Chronic Obstructive Pulmonary Disease. Radiology. 2025. PMID: 41400467. doi:10.1148/radiol.251296
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。