文献速递神经头颈MR

深度学习模型降低小脑脑桥角池增强MRI对比剂剂量

A deep learning model to reduce agent dose for contrast-enhanced MRI of the cerebellopontine angle cistern.
PubMed 文献 · Eur Radiol · 2025-12-02

这项多中心回顾性研究利用前庭神经鞘瘤患者的T1与增强T1图像模拟不同减量水平的低剂量增强图像,训练深度学习模型从低剂量模拟图恢复标准剂量增强T1。结果显示,输入剂量从低到高时恢复图像的结构相似性指数从0.639升至0.993、峰值信噪比从21.6 dB升至41.4 dB;10%输入剂量下分割Dice从0.673升至0.734,10%与30%输入剂量的恢复图像质量均优,后者信息更丰富,作者认为可在标准剂量10%–30%下完成病灶检出与诊断表征。

要点

  • 深度学习模型可将小脑脑桥角池增强T1的钆对比剂剂量降至标准剂量的10%–30%。
  • 10%输入剂量下恢复图像的分割Dice由0.673升至0.734,平均表面距离由1.00 mm降至0.59 mm。
  • 10%与30%输入剂量的恢复图像质量评分均为3分,30%剂量图像信息更丰富(4分)。

核心结论

  • 深度学习模型改善了小脑脑桥角池低剂量MRI的图像质量,使病灶检出与诊断表征可在标准剂量的10%–30%下完成。

研究设计与样本

  • 多中心回顾性研究,纳入72例前庭神经鞘瘤患者的203次MRI检查(平均年龄58.51±14.73岁,男性39例),用T1与增强T1模拟不同对比剂减量水平的低剂量增强图像,训练深度学习模型从低剂量模拟图恢复标准剂量增强T1,并由一名头颈放射科医师对恢复图像的多方面进行评分。

关键影像表现/征象

  • 随着输入剂量增加,恢复增强T1的结构相似性指数从0.639±0.113升至0.993±0.009,峰值信噪比从21.6±3.73 dB升至41.4±4.84 dB。
  • 10%输入剂量下,使用深度学习恢复的增强T1进行分割,Dice从0.673提高到0.734。
  • 10%输入剂量下,95% Hausdorff距离从2.38 mm降至2.07 mm,平均表面距离从1.00 mm降至0.59 mm。
  • 10%与30%输入剂量的深度学习恢复增强T1均显示优秀图像质量(3分,四分位距[Q3-Q1]=3-3与3分,四分位距[Q3-Q1]=4-3)。
  • 30%输入剂量的恢复图像被认为信息更丰富(4分,四分位距[Q3-Q1]=4-3)。

诊断标准与关键数值

  • 以结构相似性指数与峰值信噪比评估恢复增强T1与标准剂量图像的相似度,输入剂量越高数值越高。
  • 以Dice、95% Hausdorff距离与平均表面距离评估分割性能,10%输入剂量下分别为0.734、2.07 mm与0.59 mm。
  • 由一名头颈放射科医师对恢复图像质量与诊断表征进行评分,10%与30%输入剂量图像质量均为3分。

临床应用与阅片要点

  • 深度学习恢复的低剂量增强T1可用于前庭神经鞘瘤的病灶检出与诊断表征。
  • 采用标准剂量10%–30%的输入剂量即可获得可用于诊断的恢复图像,30%剂量图像信息更丰富。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate a deep learning (DL) model for reducing the agent dose of contrast-enhanced T1-weighted MRI (T1ce) of the cerebellopontine angle (CPA) cistern.

MATERIALS AND METHODS: In this multicenter retrospective study, T1 and T1ce of vestibular schwannoma (VS) patients were used to simulate low-dose T1ce with varying reductions of contrast agent dose. DL models were trained to restore standard-dose T1ce from the low-dose simulation. The image quality and segmentation performance of the DL-restored T1ce were evaluated. A head and neck radiologist was asked to rate DL-restored images in multiple aspects, including image quality and diagnostic characterization.

RESULTS: 203 MRI studies from 72 VS patients (mean age, 58.51 ± 14.73, 39 men) were evaluated. As the input dose increased, the structural similarity index measure of the restored T1ce increased from 0.639 ± 0.113 to 0.993 ± 0.009, and the peak signal-to-noise ratio increased from 21.6 ± 3.73 dB to 41.4 ± 4.84 dB. At a 10% input dose, using DL-restored T1ce for segmentation improved the Dice from 0.673 to 0.734, the 95% Hausdorff distance from 2.38 mm to 2.07 mm, and the average surface distance from 1.00 mm to 0.59 mm. Both DL-restored T1ce from 10% and 30% input doses showed excellent image quality (3, interquartile range (IQR) [Q3-Q1] = 3-3 and 3, IQR [Q3-Q1] = 4-3), with the latter being considered more informative (4, IQR [Q3-Q1] = 4-3).

CONCLUSION: The DL model improved the image quality of low-dose MRI of the CPA cistern, which makes lesion detection and diagnostic characterization possible with 10-30% of the standard dose.

KEY POINTS: Question Deep learning models that aid in the reduction of contrast agent dose are not extensively evaluated for MRI of the cerebellopontine angle cistern. Findings Deep learning models restored the low-dose MRI of the cerebellopontine angle cistern, yielding images sufficient for vestibular schwannoma diagnosis and management. Clinical relevance Deep learning models make it possible to reduce the use of gadolinium-based contrast agents for contrast-enhanced MRI of the cerebellopontine angle cistern.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Chen Y, Weber RA, Neve OM, et al. A deep learning model to reduce agent dose for contrast-enhanced MRI of the cerebellopontine angle cistern. Eur Radiol. 2025. PMID: 41329327. doi:10.1007/s00330-025-12187-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。