文献速递神经技术与安全CT

使用扩展Hounsfield单位CT准确显示脑深部电刺激电极触点位置

Accurate localization of deep brain stimulation electrode contacts using extended Hounsfield unit computed tomography.
PubMed 文献 · Eur Radiol · 2025-12-20

该回顾性研究纳入29例患者共58根脑深部电刺激电极,比较常规CT与扩展Hounsfield单位(EHU)CT对电极触点的定位。定量分析显示两种方法定位一致性接近完美(ICC≈1),但EHU-CT在100%病例中可清晰辨识所有触点,而常规CT因金属伪影无法区分单个触点,且定位对窗位调整敏感。

要点

  • EHU-CT可100%清晰显示所有脑深部电刺激电极触点,常规CT无法区分单个触点。
  • EHU-CT与常规CT定位一致性接近完美(ICC≈1),但EHU-CT对显示设置不敏感。
  • 常规CT电极定位对窗位调整敏感,尤其沿z轴方向。

核心结论

  • EHU-CT能一致且直接地显示脑深部电刺激的单个电极触点,是常规CT的可靠替代方案,其对显示设置敏感性低且可读性更好,可能改善术中决策和术后程控。

研究设计与样本

  • 回顾性研究,纳入29例接受脑深部电刺激植入的患者共58根电极,术后行常规CT与EHU-CT(扩展至40000 HU)重建,两名独立评估者按标准化方案定位电极触点,采用组内相关系数和欧氏距离评价方法间及评估者间一致性。

关键影像表现/征象

  • EHU-CT上所有电极触点均可清晰辨识,常规CT因 Blooms 伪影无法区分单个触点。
  • 常规CT电极定位对窗位调整敏感,尤其沿z轴方向。

诊断标准与关键数值

  • EHU-CT与常规CT电极定位一致性ICC≈1,评估者间一致性高。
  • EHU-CT在100%病例中所有触点清晰可辨,常规CT无法区分单个触点。

临床应用与阅片要点

  • EHU-CT可直接显示单个电极触点,有助于术中调整和术后程控。
  • 常规CT定位需注意窗位调整对结果的影响,尤其沿z轴方向。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Accurate localization of deep brain stimulation (DBS) electrodes is critical for effective therapy. Conventional CT is widely used postoperatively but fails to delineate individual electrode contacts due to metallic artifacts. This study aimed to evaluate extended Hounsfield unit (EHU) CT - using an expanded scale up to 40,000 HU- for accurate localization of individual DBS electrode contacts.

MATERIALS AND METHODS: This retrospective study included 29 patients (58 DBS electrodes) who underwent DBS implantation. Postoperative imaging comprised both conventional CT and EHU-CT reconstructions. Two independent raters localized electrode contacts using a standardized protocol. Inter-method and inter-rater agreement were quantified using intraclass correlation coefficients (ICCs) and Euclidean distances. Qualitative assessments of contact visibility were also performed.

RESULTS: Quantitative analysis showed near-perfect agreement between EHU-CT and conventional CT (ICC ≈ 1), with high inter-rater consistency. However, qualitative evaluation revealed superior contact visualization with EHU-CT: all contacts were clearly identifiable in 100% of cases, while conventional CT consistently failed to distinguish individual contacts due to blooming artifacts. Conventional CT localizations were also sensitive to window-level adjustments, particularly along the z-axis.

CONCLUSION: EHU-CT enables consistent and direct visualization of individual DBS contacts and provides a robust alternative to conventional CT. Its reduced sensitivity to display settings and improved interpretability may enhance intra-operative decision-making and postoperative programming, supporting more reliable DBS workflows.

KEY POINTS: Question Accurate deep brain stimulation (DBS) electrode localization is crucial for optimal intra-operative adjustments and outcomes, yet conventional CT is hindered by metallic artifacts limiting individual contact visualization. Findings Extended Hounsfield unit (EHU)-CT and conventional CT showed near-perfect agreement in electrode localization, but EHU-CT provided clearly superior visualization of individual electrode contacts. Clinical relevance By enabling direct visualization of individual contacts through an extended Hounsfield scale, EHU-CT can improve intra-operative decision-making and postoperative programming, potentially enhancing DBS localization accuracy and patient outcomes.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kremer NI, van Hulzen ALJ, Tamasi K, et al. Accurate localization of deep brain stimulation electrode contacts using extended Hounsfield unit computed tomography. Eur Radiol. 2025. PMID: 41420706. doi:10.1007/s00330-025-12179-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。