血管造影与基于造影的分数流在评估颅内椎基底动脉狭窄中的对比
本研究回顾性分析120例颅内椎基底动脉狭窄(IVBS)患者,比较基于造影的分数流(Angio-FF)与狭窄程度(DS)识别症状性病变的诊断效能。症状性病变的Angio-FF中位数显著低于无症状病变(0.66 vs. 0.88,p < 0.001),Angio-FF的AUC优于DS(0.847 vs. 0.640;p < 0.001),最佳截断值为0.74,敏感度71.4%、特异度86.1%、准确率75.8%。
要点
- 症状性IVBS的Angio-FF中位数显著低于无症状病变(0.66 vs. 0.88,p < 0.001)。
- Angio-FF识别症状性IVBS的AUC为0.847,优于DS的0.640(p < 0.001)。
- Angio-FF最佳截断值0.74,敏感度71.4%、特异度86.1%、准确率75.8%。
核心结论
- Angio-FF在识别症状性IVBS方面优于DS,可能作为识别症状性IVBS的可靠工具用于不同患者人群。
研究设计与样本
- 本研究中心回顾性分析,纳入年龄>18岁、经数字减影血管造影确认的单侧IVBS(40-90%)患者120例,其中症状性84例、无症状36例,使用专用软件计算Angio-FF,比较Angio-FF与DS的诊断准确率、敏感度、特异度、阳性/阴性预测值和AUC。
诊断标准与关键数值
- 症状性IVBS的Angio-FF中位数0.66 vs. 无症状0.88(p < 0.001);Angio-FF识别症状性IVBS的AUC 0.847 vs. DS 0.640(p < 0.001);最佳Angio-FF截断值0.74,敏感度71.4%、特异度86.1%、准确率75.8%。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the diagnostic performance of Angio-based fractional flow (Angio-FF) compared to the degree of stenosis (DS) in identifying symptomatic intracranial vertebrobasilar artery stenosis (IVBS) and assess its utility across lesion subgroups.
MATERIALS AND METHODS: A retrospective analysis of patients with IVBS was conducted at our institution. Inclusion criteria included patients aged > 18 years with unilateral IVBS (40-90%) confirmed by digital subtraction angiography. Angio-FF was calculated using specialized software. Diagnostic accuracy, sensitivity, specificity, positive/negative predictive values (PPV/NPV), and the area under the curve (AUC) were compared between Angio-FF and DS.
RESULTS: In 120 patients, 84 were symptomatic, and 36 were asymptomatic. The median Angio-FF value was significantly lower in symptomatic lesions (0.66 vs. 0.88, p < 0.001). Angio-FF showed superior diagnostic performance over DS in identifying symptomatic IVBS (AUC: 0.847 vs. 0.640; p < 0.001). The optimal Angio-FF cutoff value for distinguishing symptomatic IVBS was 0.74, with sensitivity, specificity, and accuracy of 71.4%, 86.1%, and 75.8%, respectively. Additionally, Angio-FF showed relatively good diagnostic performance across various lesion subgroups, including different lesion lengths, location, and DS.
CONCLUSIONS: Angio-FF outperformed DS in identifying symptomatic IVBS. It may serve as a reliable tool for identifying symptomatic IVBS in diverse patient populations.
KEY POINTS: Question Does Angio-based fractional flow (Angio-FF) provide superior diagnostic accuracy compared to the degree of stenosis alone in identifying symptomatic intracranial vertebrobasilar artery stenosis (IVBS)? Findings Angio-FF demonstrated superior diagnostic accuracy, with an optimal cutoff value of 0.74 and consistent performance across various lesion subgroups. Clinical relevance Angio-FF improves hemodynamic risk stratification in IVBS and may facilitate more individualized treatment strategies.
引用
- Liu Y, Shao G, Liu Y, et al. Angiography versus angio-based fractional flow in assessing intracranial vertebrobasilar artery stenosis. Eur Radiol. 2025. PMID: 41342928. doi:10.1007/s00330-025-12183-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。