1型脑脊液漏患者的硬膜移位征
回顾性比较23例确诊1型脑脊液漏患者的3D T2 FIESTA MR与超快动态CT脊髓造影,硬膜移位征见于13例上胸段漏中的12例(92%),其余10例颈、下胸或腰段漏均未见该征;9例(72%)漏口与征象同层,3例漏口低一层,作者认为该征有助于规划超快动态CT脊髓造影。
要点
- 上胸段1型漏中硬膜移位征出现率92%(12/13),颈、下胸或腰段漏均未见。
- 硬膜移位征与漏口同层占72%(9/13),其余3例漏口位于征象下一层。
- 作者认为3D FIESTA硬膜移位征可用于规划超快动态CT脊髓造影。
核心结论
- 3D FIESTA序列及硬膜移位征可显示上胸段1型漏的潜在部位,作者认为其有助于规划超快动态CT脊髓造影,可能减少检查时间和辐射剂量。
研究设计与样本
- 回顾性研究,23例确诊1型脑脊液漏患者接受脊柱3D T2 FIESTA加权MR及超快动态CT脊髓造影,22例比较两种模态与漏口位置;1例本院用常规CT脊髓造影、后于另一机构行超快动态CT脊髓造影确认漏口;两名神经放射科医生盲法评估。
关键影像表现/征象
- 上胸段硬膜移位征见于13例上胸段漏中的12例(92%)。
- 颈、下胸或腰段漏的其余10例均未识别出硬膜移位征。
- 9例(72%)上胸段1型漏口与硬膜移位征位于完全相同层面。
- 其余3例漏口位于硬膜移位征下一层。
- 3例漏口低于可见硬膜移位征者中,1例在漏口层面见硬膜不连续(硬膜撕裂)。
诊断标准与关键数值
- 硬膜移位征定义:3D T2 FIESTA加权MR上可见的硬膜移位征象。
- 上胸段漏中硬膜移位征检出12/13(92%)。
- 硬膜移位征与漏口同层9/13(72%)。
临床应用与阅片要点
- 作者认为3D FIESTA序列及硬膜移位征可用于规划超快动态CT脊髓造影。
- 作者认为该征可能减少检查时间和辐射剂量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND OBJECTIVES: The precise site of dural leaks in patients with spontaneous intracranial hypotension (SIH) is challenging to identify. We investigated for the first time the ability of the dural displacement sign seen on 3D T2 FIESTA (Fast Imaging Employing Steady-state Acquisition) weighted MR imaging to depict epidural collections and show the leakage site in type 1 leaks in patients with SIH. MATERIALS AND METHODS: In a retrospective study, 23 patients with confirmed type 1 leakage received an MR of the spine with 3D T2 FIESTA-weighted imaging and ultrafast dynamic CT myelography. The two modalities were compared in 22 patients in relation to the leakage site. In one patient, conventional CT myelography (CTM) was used at our site, but an ultrafast dynamic CT myelography was later conducted at another site and confirmed the leakage location. Two neuroradiologists performed the evaluations while blinded. RESULTS: Dural displacement sign in the upper thoracic spine was identified in 12 of 13 patients (92%) in the upper thoracic spine, whereas it was not identified in the remaining 10 patients with leaks in the cervical, lower thoracic or lumbar regions. A Type 1 leakage in the upper thoracic region was at the exact same level as the dural displacement sign in 9 (72%) patients and in the remaining 3 the leakage level was located at one level below the dural displacement sign. In one of the 3 patients where the leakage was located at the level below the visible dural displacement sign, a dural tear at the leakage level in the form of discontinuity of the dura was identified. CONCLUSIONS: 3D FIESTA sequences and the dural displacement sign show the potential site of type 1 leakage in the upper thoracic spine. We find that the 3D FIESTA sequence and the dural displacement sign can be valuable when planning ultrafast dynamic CT myelography. This may reduce the investigation time and the radiation doses.