基于三分类放射组学模型预测成人型弥漫性胶质瘤IDH突变和1p19q共缺失状态
研究纳入本院480例经病理证实的弥漫性胶质瘤患者(按7:3随机分为训练集336例和内部验证集144例)及TCIA外部验证集105例,构建三分类MRI放射组学模型预测IDH野生型、IDH突变伴1p19q非共缺失和IDH突变伴1p19q共缺失三种亚型。支持向量机分类器结合常规MRI序列基于肿瘤ROI为最佳模型,三个亚型预测的AUC分别为0.963、0.964和0.929。
要点
- 三分类MRI放射组学模型术前预测成人弥漫性胶质瘤分子亚型,最佳模型三个亚型AUC为0.963、0.964和0.929。
- SVM分类器结合常规MRI序列基于肿瘤ROI为最佳诊断模型,总体准确率(微平均)为0.860。
- 模型在内部验证集和外部验证集均得到验证,作者认为对胶质瘤诊断和风险分层有潜在价值。
核心结论
- 三分类MRI放射组学可术前预测成人弥漫性胶质瘤分子亚型,性能令人满意,作者认为对胶质瘤患者诊断和风险分层有潜在价值。
研究设计与样本
- 回顾性研究,本院480例经病理证实的弥漫性胶质瘤患者按7:3随机分为训练集336例和内部验证集144例,TCIA外部验证集105例;所有患者行常规MRI和DWI扫描;采用两种ROI分割方案(肿瘤ROI和肿瘤+瘤周水肿ROI)及含与不含ADC图的MRI序列,测试6种机器学习分类器筛选最佳模型。
诊断标准与关键数值
- 最佳模型为SVM分类器结合常规MRI序列基于肿瘤ROI,IDHwt预测AUC为0.963、IDHmut-intact预测AUC为0.964、IDHmut-codel预测AUC为0.929,对应准确率分别为0.902、0.929和0.890,总体准确率(微平均)为0.860。
局限性
- 本文为回顾性研究,经伦理批准并豁免知情同意。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To predict the genetic subtypes of adult-type diffuse gliomas with three-class MRI radiomics.
MATERIAL AND METHODS: Four hundred and eighty patients with pathologically proved diffuse gliomas from our institution were randomly divided into training set (n = 336) and internal validation set (n = 144) according to a ratio of 7 to 3, and 105 patients from the cancer imaging archive (TCIA) were utilized as an external validation set. All patients were classified into IDH wild-type (IDHwt), IDH-mutant with 1p19q-noncodeleted (IDHmut-intact) and IDH-mutant with 1p19q-codeleted (IDHmut-codel) subtypes, and all the patients underwent conventional MR imaging and diffusion weighted imaging (DWI) scans. Two regions of interest (ROI) segmentation schemes (tumor ROI and tumor with peritumoral edema ROI) and MRI sequences with and without apparent diffusion coefficient (ADC) maps were tested with 6 machine learning classifiers to filter the optimal models.
RESULTS: Support vector machine (SVM) classifier combined with conventional MR sequences based on tumor ROI was proved to be the best diagnostic model, with the area under the curve (AUC) of 0.963, 0.964, and 0.929, and accuracy of 0.902, 0.929, and 0.890 for IDHwt, IDHmut-intact, and IDHmut-codel prediction, respectively, and overall accuracy (micro average accuracy) of 0.860. The model was validated in both internal and external validation sets.
CONCLUSIONS: Three-class MRI radiomics can be used preoperatively in predicting the molecular subtype of adult diffuse gliomas with satisfactory performance and show potential value for the diagnosis and risk stratification in glioma patients. This retrospective study received ethics approval with a waiver of informed consent.
引用
- Li Y, Wang M, Zhang J, et al. Prediction of IDH-mutation and 1p19q-codeletion status in adult-type diffuse gliomas using three-class radiomics models. Eur J Radiol. 2025. PMID: 41364966. doi:10.1016/j.ejrad.2025.112601
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。