文献速递骨肌技术与安全DR

基于X线的深度学习模型检测踝关节与足部骨折的诊断效能:系统综述与Meta分析

Diagnostic performance of X-ray-based deep learning models for detecting ankle and foot fractures: a systematic review and meta-analysis.
PubMed 文献 · Skeletal Radiol · 2025-11-19

本系统综述与Meta分析纳入14项研究,评估基于X线图像的深度学习模型检测踝关节与足部骨折的诊断准确性。汇总敏感度为93.2%、特异度为94.5%,多视图与单视图X线间无显著差异,跟骨骨折模型的诊断效能显著优于足部或踝关节骨折模型。

要点

  • 深度学习模型检测踝关节与足部骨折的汇总敏感度93.2%、特异度94.5%。
  • 跟骨骨折模型的汇总敏感度95.1%、特异度98.3%,显著优于足部或踝关节骨折模型。
  • 多视图与单视图X线、验证集与测试集、内部与外部测试对诊断效能无显著影响。

核心结论

  • 深度学习模型可被认为是检测踝关节与足部骨折的一种显著准确的方法。

研究设计与样本

  • 系统综述与Meta分析,检索四个数据库截至2025年9月30日,共筛选506项研究,最终纳入14项研究,采用双变量随机效应模型进行Meta分析,PROSPERO注册号CRD42024624044。

诊断标准与关键数值

  • 全部代表性模型汇总敏感度93.2%(95%CI 88.8-95.9%)、特异度94.5%(95%CI 90.1-97.0%),I²为6.6%。
  • 汇总F1评分为0.94(95%CI 0.88-0.97)。
  • 跟骨骨折模型汇总敏感度95.1%(95%CI 93.0-96.6%,P=0.008)、特异度98.3%(95%CI 97.00-99.0%)、诊断比值比1751.8(95%CI 445.9-6882.5)。
  • 多视图与单视图X线的敏感度比较P=0.64、特异度比较P=0.89,均无显著差异。

临床应用与阅片要点

  • 深度学习模型可作为X线检测踝关节与足部骨折的辅助手段,其汇总敏感度93.2%、特异度94.5%。
  • 跟骨骨折检测模型效能更高(敏感度95.1%、特异度98.3%),阅片时可优先参考。
  • 多视图与单视图X线对模型效能无显著影响,验证集与测试集类型亦不影响效能。

局限性

  • 需要更大样本、外部验证和临床实施的研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Lower extremity fractures are prevalent in vulnerable populations leading to significant burdens, which highlight the need for timely and precise diagnosis. Integrating deep learning with imaging findings has shown promising results for enhancing fracture detection accuracy. This study assesses the diagnostic accuracy of AI models using X-ray images to detect ankle and foot fractures and investigates the probable factors influencing their performance.

MATERIALS AND METHODS: A comprehensive search of four databases was done up to September 30th, 2025. Studies that investigated the accuracy of deep learning models for the detection of ankle and foot fractures utilizing X-rays were included. A bivariate random-effects model was used to perform meta-analysis.

RESULTS: A total of 506 studies were reviewed, and 14 were included in the meta-analysis. Analysis of all the representative models of the included studies had a cumulative sensitivity and specificity of 93.2% and 94.5% (95% CI 88.8-95.9%, 90.1-97.0%, respectively, I2 6.6%). The pooled F1 score was estimated at 0.94 (95% CI 0.88-0.97). Subgroup analysis revealed no difference in the sensitivity or specificity of studies using multi-view vs. single-view X-rays (P = 0.64, P = 0.89, respectively). Models detecting calcaneal fractures performed significantly better than models detecting foot or ankle fractures, with a pooled sensitivity of 95.1% (95% CI 93.0-96.6%, P = 0.008), specificity of 98.3% (95% CI 97.00-99.0%), and a DOR of 1751.8 (95% CI 445.9-6882.5). The type of dataset used (validation vs. test, internal testing vs. external testing) did not significantly affect performance.

CONCLUSION: Deep learning models can be considered a notably accurate method for the detection of ankle and foot fractures. Further studies with larger samples, external validation, and clinical implementations are required.

PROSPERO REGISTRATION: This systematic review and meta-analysis study was registered with PROSPERO, registration number CRD42024624044.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Pahlevan-Fallahy MT, Hosseinzadeh N, Shaker F, et al. Diagnostic performance of X-ray-based deep learning models for detecting ankle and foot fractures: a systematic review and meta-analysis. Skeletal Radiol. 2025. PMID: 41254255. doi:10.1007/s00256-025-05078-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。