低能级图像联合深度学习图像重建在肝硬化患者双能CT门静脉成像中提升图像质量、降低辐射与对比剂剂量的价值
60例肝硬化拟行CTPV患者随机分为S组(120 kVp、NI 10、对比剂1.4 ml/kg、50% ASIR-V)与L组(双能CT 80/140 kV、NI 13、对比剂1.0 ml/kg、40/50/60 keV DLIR-H重建)。L组有效辐射剂量较S组降低48%(4.10±1.56 vs 7.88±1.08 mSv),对比剂剂量降低32%(67.26±8.74 vs 99.12±8.84 ml),均P<0.001。50 keV图像在图像对比度、小血管显示及整体图像质量方面主观评分更高,结论认为低keV(50 keV)联合DLIR-H可在提升CTPV图像质量的同时降低辐射与对比剂剂量。
要点
- 肝硬化CTPV采用50 keV DLIR-H重建,有效辐射剂量较120 kVp常规方案降低48%。
- 对比剂剂量由1.4 ml/kg降至1.0 ml/kg,实际用量降低32%。
- 门静脉CNR与SNR随能级降低而升高,40 keV最高,但50 keV主观图像质量更优。
核心结论
- 肝硬化患者CTPV采用双能CT低keV(50 keV)图像联合DLIR-H重建,可降低有效辐射剂量48%、降低对比剂剂量32%,同时仍提升图像质量。
研究设计与样本
- 随机对照研究,纳入60例拟行CTPV的肝硬化患者,随机分为S组与L组。
- S组采用120 kVp、噪声指数10、对比剂1.4 ml/kg,以50% ASIR-V重建。
- L组采用双快管切换双能CT(80与140 kV)、噪声指数13、对比剂1.0 ml/kg,以40、50、60 keV DLIR-H重建。
- 记录有效辐射剂量与对比剂剂量,计算门静脉CNR与SNR,并由两名放射科医师盲法以5分法进行主观图像质量评分。
关键影像表现/征象
- L组门静脉CNR与SNR随能级降低而逐渐升高(P<0.05),40 keV时最高。
- 50 keV图像在图像对比度、小血管显示及整体图像质量方面主观评分高于40 keV图像,且图像噪声明显低于40 keV图像。
- 两名医师主观评分一致性极好(kappa值≥0.70)。
诊断标准与关键数值
- 主观图像质量采用5分法评分,由两名放射科医师盲法完成,一致性kappa值≥0.70。
- L组中50 keV图像在图像对比度、小血管显示及整体图像质量方面主观评分更高,图像噪声明显低于40 keV图像。
临床应用与阅片要点
- 肝硬化CTPV可考虑采用双能CT 50 keV图像联合DLIR-H重建,以在降低辐射与对比剂剂量的同时维持或提升图像质量。
- 能级降低可提高门静脉CNR与SNR,但40 keV图像噪声明显高于50 keV,阅片时需权衡对比度与噪声。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To explore feasibility of low-energy images in dual-energy computed tomography (DECT) combined with deep learning image reconstruction (DLIR) to improve image quality, reduce radiation and contrast doses in computed tomography portal venography (CTPV) for cirrhotic patients.
MATERIALS AND METHODS: Sixty cirrhotic patients scheduled for CTPV were randomly divided into group S and group L. Group S used 120 kVp, noise index (NI) of 10, contrast dosage of 1.4 ml/kg, reconstructed with 50% adaptive statistical iterative reconstruction-V (ASIR-V). Group L used DECT with double fast tube switching (80 and 140 kV), NI of 13, contrast dosage of 1.0 ml/kg, and reconstructed with 40, 50, and 60 keV DLIR-H. The effective radiation dose (ED) and contrast dose were recorded. The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of portal vein were calculated. The subjective image quality was scored by two radiologists blindly using 5-point scale.
RESULTS: Compared to group S, group L showed an ED reduction of 48% (4.10 ± 1.56 vs 7.88 ± 1.08 mSv) and contrast dose reduced 32% (67.26 ± 8.74 vs 99.12 ± 8.84 ml) (all P < 0.001). The CNR and SNR of the portal vein in group L gradually increased with decreasing energy levels (P < 0.05) and were highest at 40 keV. The two radiologists had excellent consistency in the subjective score (kappa value ≥ 0.70). The 50 keV image had higher subjective score in image contrast, small vessel display, and overall image quality, but much low image noise than the 40 keV images.
CONCLUSION: The use of low-keV (50 keV) images in DECT combined with DLIR-H can reduce ED 48% and contrast doses 32%, while still improving image quality in CTPV.
引用
- Li M, Jia Y, Fan L, et al. The value of low-energy images combined with deep learning image reconstruction to improve image quality, reduce radiation and contrast doses in dual-energy computed tomography (CT) portal venography in cirrhotic patients. Clin Radiol. 2025. PMID: 41297158. doi:10.1016/j.crad.2025.107139
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。