优化光子计数CT肺动脉血管成像的稳健性:联合混合团注、固定扫描延迟与低keV重建
本研究回顾性纳入2023年7月至2024年1月间150例行光子计数CT肺动脉血管成像(CTPA)的患者,比较三种对比剂注射方案(队列1:50/0 mL对比剂/生理盐水混合,团注跟踪触发;队列2:50/50 mL混合;队列3:35/35 mL混合,后两者固定扫描延迟),并分别以40、55、67 keV重建。结果显示队列1平均HU值显著高于队列2和队列3,40 keV重建HU值显著高于55 keV和67 keV;40 keV下队列1有3例(1.5%)对比剂注射低于350 HU,队列2和3均无低于350 HU者。阅片者认为40 keV血管评估对比剂显示最佳(队列2评分4.7±0.5,55 keV为4.5±0.7,67 keV为3.6±1.0,p<0.001)。结论提示,采用50或35 mL对比剂与等体积生理盐水混合注射并固定扫描延迟的方案,联合40 keV血管重建,可能是最稳健的PCCT CTPA对比剂注射方案。
要点
- 40 keV重建在主肺动脉及段动脉的HU值显著高于55 keV和67 keV,且被阅片者评为血管评估对比剂显示最佳。
- 队列1(50/0 mL混合,团注跟踪)平均HU值显著高于队列2(50/50 mL混合)和队列3(35/35 mL混合),后两者均采用固定扫描延迟。
- 40 keV下仅队列1出现3例(1.5%)对比剂注射低于350 HU,队列2和队列3均无低于350 HU者。
核心结论
- 研究提示,采用50或35 mL对比剂与等体积生理盐水混合注射并固定扫描延迟的方案,联合40 keV血管重建,可能是PCCT CTPA最稳健的对比剂注射方案;40 keV血管重建受放射科医生青睐,并最大限度减少非诊断性对比剂注射。
研究设计与样本
- 回顾性纳入2023年7月至2024年1月间行光子计数CT肺动脉血管成像(PCCT CTPA)的患者150例(49例男性,101例女性;平均年龄60.6±16.6岁),每个队列50例;按水等效直径在队列间进行匹配;图像重建于40、55和67 keV;由三名盲法阅片者进行主观图像质量评分。
关键影像表现/征象
- 主肺动脉和段动脉的平均HU值在队列1>队列2>队列3,差异有统计学意义(p<0.001)。
- 平均HU值在40 keV>55 keV>67 keV,差异有统计学意义(p<0.001)。
- 40 keV下,队列1有3例(1.5%)对比剂注射低于350 HU,队列2和队列3均无低于350 HU者。
- 阅片者评价队列2在40 keV的血管评估对比剂显示最佳(4.7±0.5),高于55 keV(4.5±0.7)和67 keV(3.6±1.0),差异有统计学意义(p<0.001)。
诊断标准与关键数值
- 对比剂注射非诊断性阈值定义为CT值低于350 HU:40 keV下队列1有3例(1.5%)低于350 HU,队列2和队列3均无低于350 HU者。
- 图像重建keV:40、55和67 keV;主观图像质量由三名盲法阅片者评分。
临床应用与阅片要点
- 对于PCCT CTPA,采用50或35 mL对比剂与等体积生理盐水混合注射并固定扫描延迟的方案,联合40 keV血管重建,可能减少非诊断性对比剂注射。
- 40 keV血管重建被阅片者评为对比剂显示最佳,可用于血管评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study's purpose was to create a robust, optimized CTPA protocol by exploring different combinations of keV reconstructions and contrast infusion parameters.
MATERIALS & METHODS: PCCT CTPAs between July 2023-January 2024 were retrospectively included, spanning three contrast injection protocols during a period of protocol optimization: cohort 1: 50/0mL contrast/saline mix using bolus tracking; cohort 2: 50/50 mL mix and cohort 3: 35/35 mL mix, both with fixed scan delay. Patients were matched by water-equivalent diameter between cohorts. Images were reconstructed at 40, 55 and 67 keV. Hounsfield unit (HU) values were measured in the main pulmonary artery and the segmental arteries. Three blinded radiologists rated subjective image quality.
RESULTS: 150 patients (49 men, 101 women) were evaluated (mean age: 60.6 ± 16.6 years), 50 per cohort. Mean HU values were significantly higher in cohort 1 > 2 > 3 (p < 0.001) and were significantly higher at 40 > 55 > 67 keV (p < 0.001). At 40 keV, three (1.5 %) cohort 1 contrast injections were < 350 HU, with none < 350 HU in cohorts 2 or 3. Readers rated contrast best at 40 keV for vascular assessment (cohort 2: 4.7 ± 0.5, vs 4.5 ± 0.7 at 55 keV, vs 3.6 ± 1.0 at 67 keV, p < 0.001).
CONCLUSION: Our study suggests that the most robust PCCT contrast injection protocol for CTPA is a mixed injection of 50 or 35 mL of contrast with the same volume of saline, using a fixed scan delay. 40 keV vascular reconstructions are favored by radiologists and minimize non-diagnostic contrast injections.
引用
- Schwartz FR, Khanungwanitkul K, Czajkowski B, et al. Optimizing photon-counting CT pulmonary angiography for robustness, combining mixed bolus, fixed scan delay and low keV. Eur J Radiol. 2025. PMID: 41275634. doi:10.1016/j.ejrad.2025.112540