文献速递儿科影像骨肌CTDR

亚毫西弗CT用于儿童及年轻成人髋部成像:骨盆X线摄影的低辐射剂量替代方案

Sub-mSv CT for pediatric and young adult hip imaging: a low-radiation-dose alternative to pelvic radiography.
PubMed 文献 · Pediatr Radiol · 2025-11-28

回顾性比较29例儿童及年轻成人髋部超低剂量CT与骨盆前后位X线摄影的辐射剂量,超低剂量CT平均有效剂量0.29 mSv,与单次骨盆前后位X线摄影0.27 mSv无显著差异,而累积X线剂量0.74 mSv显著更高。

要点

  • 儿童及年轻成人髋部超低剂量CT平均有效剂量0.29 mSv,与单次骨盆前后位X线摄影0.27 mSv无显著差异。
  • 累积X线摄影剂量0.74 mSv显著高于超低剂量CT,提示超低剂量CT可提供三维诊断质量图像且辐射剂量相当。
  • 儿童组超低剂量CT剂量0.33 mSv vs 骨盆前后位X线摄影0.26 mSv,年轻成人组0.23 mSv vs 0.29 mSv,均无显著差异。

核心结论

  • 超低剂量CT是儿童及年轻成人髋部成像的临床可行方法,可提供诊断质量CT图像且辐射剂量显著降低,与单次骨盆前后位X线摄影剂量水平相当。

研究设计与样本

  • 回顾性研究,检索大型三级儿童医院2023年12月至2024年5月图像档案,纳入29例(男9例,女20例)同时期髋部超低剂量CT和骨盆前后位X线摄影患者,儿童组(<18岁)17例、年轻成人组(18-30岁)12例。

诊断标准与关键数值

  • 超低剂量CT平均有效剂量:儿童组0.33 mSv,年轻成人组0.23 mSv,全队列0.29 mSv。
  • 骨盆前后位X线摄影平均有效剂量:儿童组0.26 mSv,年轻成人组0.29 mSv,全队列0.27 mSv。
  • 累积X线摄影平均有效剂量:儿童组0.73 mSv,年轻成人组0.76 mSv,全队列0.74 mSv,显著高于超低剂量CT。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Radiography is routinely used to evaluate the pediatric and young adult pelvis and hips. Unfortunately, the 2D nature of this imaging modality is insufficient in accurately depicting and evaluating complex 3D anatomical structures. In contrast, computed tomography (CT) provides exquisite details of 3D anatomy, typically at the expense of a higher radiation dose. Recent studies have suggested that ultra-low-dose CT (ULDCT) with tin filtration may overcome this diagnostic imaging dilemma by offering high-quality CT images with reduced radiation exposure.

OBJECTIVE: To compare patient-specific radiation exposure of diagnostic-quality hip ULDCTs and pelvic radiographs and thereby validate an optimized clinical protocol for hip ULDCT imaging in pediatric and young adult patients.

MATERIALS AND METHODS: We retrospectively searched the image archive at our large tertiary children's hospital for hip CTs and anteroposterior (AP) pelvic radiographs performed within 6 months of each other (Dec 2023 - May 2024). The inclusion criteria were (1) hip CTs performed in accordance with our established ULDCT imaging protocol and (2) AP pelvic radiographs acquired in accordance with the American College of Radiology (ACR) guidelines. To calculate the effective doses of the pelvic radiographs and hip CTs, we used the National Cancer Institute dosimetry system for Radiography and Fluoroscopy (NCIRF) and Computed Tomography (NCICT), respectively. A paired two-tailed t-test was used to compare the effective doses of the hip CTs and AP pelvic radiographs.

RESULTS: The study cohort included 29 patients (9 males, 20 females), stratified into the pediatric group (<18 years, n=17), young adult group (18-30 years, n=12), and entire cohort, with mean ages of 10.7 (SD, 6.0), 22.3 (SD, 3.7), and 15.5 (SD, 6.9) years, respectively. The average effective doses from ULDCT were 0.33 mSv (pediatric), 0.23 mSv (young adult), and 0.29 mSv (entire cohort), not significantly different from AP pelvic radiograph doses of 0.26, 0.29, and 0.27 mSv, respectively. In contrast, cumulative radiographic doses were significantly higher at 0.73 mSv, 0.76 mSv, and 0.74 mSv.

CONCLUSION: ULDCT is a clinically feasible approach for pediatric and young adult hip imaging, offering diagnostic-quality CT images with substantially reduced radiation exposure (at a radiation dose level comparable to that of a single AP pelvic radiograph).

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Sun P, Chu R, Tsai A, et al. Sub-mSv CT for pediatric and young adult hip imaging: a low-radiation-dose alternative to pelvic radiography. Pediatr Radiol. 2025. PMID: 41313371. doi:10.1007/s00247-025-06443-8