文献速递骨肌儿科影像技术与安全DR

两种人工智能算法在儿童外周肢体创伤标准X线检查中的临床评估

Clinical evaluation of two artificial intelligence algorithms in standard radiography for post-traumatic exploration of peripheral limbs in children.
PubMed 文献 · Pediatr Radiol · 2025-11-13

连续纳入366例18岁以下因外周肢体创伤行X线检查的儿童,评估Boneview和Rayvolve两种AI骨折检测算法的诊断性能,并与放射科住院医师比较。Boneview敏感度0.85、特异度0.87,Rayvolve敏感度0.81、特异度0.93,两者AUC无显著差异(0.862 vs 0.874,P=0.62)。AI显著提升经验较少住院医师的诊断性能,但对经验较多者无显著提升。

要点

  • Boneview骨折检测敏感度0.85、特异度0.87,Rayvolve敏感度0.81、特异度0.93。
  • 两算法AUC无显著差异:Boneview 0.862 vs Rayvolve 0.874(P=0.62)。
  • AI显著提升第一年住院医师性能,对第三年住院医师无显著提升。

核心结论

  • 在同一儿童人群中评估两种AI算法显示性能一致且可接受,但性能特征存在差异,可能改善经验较少使用者的诊断结果。

研究设计与样本

  • 连续纳入366例18岁以下因外周肢体创伤由儿科急诊转诊行X线检查的儿童,涵盖手/腕、肘、肩、膝/腿、足/踝五个亚组;评估Boneview和Rayvolve两种骨折检测AI算法,关节积液和脱位仅由Boneview分析;两名放射科住院医师(第一年和第三年)先独立后借助AI判读X线片。

诊断标准与关键数值

  • Boneview骨折检测敏感度0.85、特异度0.87;Rayvolve骨折检测敏感度0.81、特异度0.93;Boneview AUC 0.862 vs Rayvolve AUC 0.874,P=0.62;Boneview积液检测敏感度0.57、特异度0.96,接近但略低于住院医师表现。

临床应用与阅片要点

  • AI辅助可显著提升经验较少住院医师的骨折诊断性能,但对经验较多住院医师无显著提升;AI辅助对积液检测未产生实际影响。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Pediatric traumatology represents a significant portion of emergency department visits, and advances in artificial intelligence (AI) provide promising tools for fracture detection on radiographs. However, few studies have assessed these tools on the same pediatric population.

OBJECTIVE: To evaluate the diagnostic performance in a pediatric population of two commercially available AI software programs for the detection of peripheral limb fractures, both alone and in comparison with radiology residents.

MATERIALS AND METHODS: Consecutive recruitment of 366 children under 18 referred by the pediatric emergency department for radiographic exploration of trauma involving peripheral limbs (five subgroups: hand/wrist, elbow, shoulder, knee/leg, and foot/ankle). Two fracture-detection AI algorithms (Boneview and Rayvolve) were evaluated, with joint effusions and dislocations analyzed only by Boneview. Two radiology residents (first and third years) interpreted the radiographs first without and then with AI assistance.

RESULTS: Boneview's sensitivity and specificity were 0.85 and 0.87, respectively, while Rayvolve's were 0.81 and 0.93. No significant difference was observed between areas under the curve of Boneview (0.862) and Rayvolve (0.874) with P-value = 0.62. AI significantly improved the performance of the least experienced resident, but not of the more experienced resident. For effusion detection, Boneview's sensitivity and specificity were 0.57 and 0.96, close to but slightly lower than the performance of the residents. AI assistance did not have real impact on residents' performance for effusion detection.

CONCLUSION: Evaluating two AI algorithms in the same pediatric population revealed consistent and acceptable performance with variations in performance profiles and may improve outcomes for less-experienced users.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Robin B, Boukheddaden R, Ifri S, et al. Clinical evaluation of two artificial intelligence algorithms in standard radiography for post-traumatic exploration of peripheral limbs in children. Pediatr Radiol. 2025. PMID: 41231299. doi:10.1007/s00247-025-06457-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。