钆增强直接磁共振关节造影实践的变化:一项基于英国调查的研究
该研究向英国骨骼放射学会成员发放问卷,评估英国肌肉骨骼放射科医生直接磁共振关节造影(MRA)的实践,并与2019年对照研究比较。45名受访者中43人常规行直接MRA,其中72%使用钆对比剂、28%改用生理盐水,许多人因后勤原因和生物蓄积担忧而改变实践,钆对比剂使用明显减少。
要点
- 45名受访者中43人常规行直接MRA,24人(56%)每月超过3例。
- 43人中72%使用钆对比剂,11人用持证制剂、19人用超说明书制剂。
- 12人(28%)以生理盐水替代钆对比剂,许多人近期改变实践。
核心结论
- 尽管MRA仍广泛使用,实践已因多种原因发生变化,钆对比剂使用明显减少。
- 作者结合现有文献和本三级中心经验讨论了这些考量及钆对比剂-MRA的替代方案。
研究设计与样本
- 研究类型为问卷调查,向英国骨骼放射学会成员发放问卷,评估是否行MRA及所用技术。
- 样本量为45名受访者,结果汇总后与2019年对照研究比较;原文未报告中心数。
诊断标准与关键数值
- 45名受访者中43人常规行直接MRA,其中24人(56%)每月超过3例。
- 43人中72%使用钆对比剂,11人使用持证制剂、19人使用超说明书制剂。
- 12名受访者(28%)使用生理盐水替代钆对比剂。
临床应用与阅片要点
- 许多受访者近期改变实践,最常见原因为后勤因素(15名受访者,33%),对生物蓄积的担忧紧随其后(14名受访者)。
- 财务成本和环境影响担忧较少见;附加评论强调Magnevist停产和常规MRI改进的影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Direct Magnetic Resonance Arthrography (MRA) is widely used for joint distension to assess intra-articular structures. Gadolinium based contrast agents (GdCA) have been used widely but concerns have emerged regarding their safety and cost. This study assesses current practice of UK musculoskeletal radiologists within the context of these recent changes.
METHODS: A questionnaire was disseminated to members of the British Society of Skeletal Radiology. This assessed whether responders performed MRA and-if so-investigated the techniques used. Responses were aggregated and compared to those from a comparator study from 2019.
RESULTS: Of 45 survey respondents, 43 regularly perform direct MRA with 24 (56%) doing over three a month. Of the 43, 72% use gadolinium with 11 using a licenced preparation and 19 using an off-licence preparation. Twelve respondents (28%) used saline instead of gadolinium. Many respondents had recently changed their practice, most commonly due to logistics (15 respondents - 33%) with concerns over bioaccumulation (14 respondents) a close second. Financial cost and environmental impact concerns were less common. Additional comments highlighted the impact of Magnevist discontinuation and improvements in conventional MRI.
CONCLUSIONS: Although MRA remains prevalent, practice has changed for various reasons with a notable reduction in GdCA use. These considerations and alternatives to GdCA-MRA are discussed with reference to the existing literature and our tertiary centre experience.
ADVANCES IN KNOWLEDGE: This study outlines the evolving state of MRA use by radiologists across the UK and discusses options to optimise safety in its use, particularly referencing GdCA use.
引用
- Uldin H, Davies AM, Botchu R, et al. Changing practices in gadolinium-enhanced direct magnetic resonance arthrography: a UK based survey. Br J Radiol. 2026. PMID: 41259655. doi:10.1093/bjr/tqaf285
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。