文献速递乳腺MR

多模型扩散加权成像全病灶直方图分析用于乳腺病变表征与分子分型

Whole-lesion histogram analysis of multi-model diffusion-weighted imaging for characterization and molecular classification of breast lesions.
PubMed 文献 · Radiol Med · 2025-11-13

回顾性纳入112例患者共90个恶性与22个良性乳腺病变,评估单指数、双指数和拉伸指数DWI模型的全病灶直方图参数在良恶性鉴别及分子亚型区分中的价值。各模型直方图参数在良恶性间均有显著差异,AUC范围0.898~0.938;联合模型未显著提高AUC。分子亚型间部分参数存在差异,结论为探索性,需进一步验证。

要点

  • 各DWI模型全病灶直方图参数在乳腺良恶性病变间均有显著差异,AUC范围0.898~0.938。
  • 联合不同模型并未显著提高良恶性鉴别的AUC(p>0.05)。
  • 部分直方图参数在Luminal A与三阴性、Luminal B与三阴性、HER2阳性与三阴性亚型间存在显著差异。

核心结论

  • 基于多模型DWI的全病灶直方图分析对乳腺病变表征具有潜在价值,但这些探索性发现来自不平衡的单中心队列,临床应用前需在更大的前瞻性研究中进一步验证。

研究设计与样本

  • 回顾性研究,纳入112例患者(90个恶性病变:Luminal A 17个、Luminal B 39个、HER2阳性18个、三阴性10个、未确定6个;良性病变22个),均行1.5 T MRI检查。

诊断标准与关键数值

  • 各模型直方图参数鉴别良恶性病变的AUC范围为0.898~0.938。
  • 联合模型未显著提高良恶性鉴别的AUC(p>0.05)。
  • DDC_75%在Luminal A与三阴性亚型间差异显著(p=0.035)。
  • Dt_50%、Dt_75%和DDC_75%可区分Luminal B与三阴性亚型(p分别为0.016、0.021和0.041)。
  • ADC_kurtosis和DDC_kurtosis在HER2阳性与三阴性亚型间差异显著(p分别为0.021和0.029)。

局限性

  • 这些探索性发现来自不平衡的单中心队列。
  • 临床应用前需在更大的前瞻性研究中进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the value of whole-lesion histogram analysis derived from mono-exponential, bi-exponential, and stretched-exponential DWI models in differentiating benign from malignant breast lesions and exploring molecular subtypes.

MATERIAL AND METHODS: This retrospective study included 112 patients with 90 malignant lesions (17 Luminal A, 39 Luminal B, 18 HER2-positive, 10 triple-negative, and 6 undetermined) and 22 benign lesions, all examined with 1.5 T MRI. Histogram parameters-apparent diffusion coefficient (ADC), true diffusion (Dt), pseudo-diffusion (Dp), perfusion fraction (f), distributed diffusion coefficient (DDC), and heterogeneity index (alpha)-were analyzed using the Mann-Whitney U test, Kruskal-Wallis test, logistic regression, ROC analysis, the DeLong test, and the chi-square test.

RESULTS: Histogram parameters from all models showed significant differences between benign and malignant lesions, with high diagnostic performance (AUC range: 0.898-0.938). However, combining the models did not significantly improve the AUC (p > 0.05). In molecular subtype analyses, DDC_75% differed significantly between Luminal A and triple-negative subtypes (p = 0.035); Dt_50%, Dt_75%, and DDC_75% distinguished Luminal B from triple-negative subtypes (p = 0.016, 0.021, and 0.041, respectively); and ADC_kurtosis and DDC_kurtosis showed significant differences between HER2-positive and triple-negative subtypes (p = 0.021 and 0.029, respectively). ROC analysis indicated variable diagnostic efficacy among parameters across molecular subtypes, and model combinations did not enhance AUC values.

CONCLUSION: Whole-lesion histogram analysis based on multi-model DWI shows potential for characterizing breast lesions. These exploratory findings, derived from an imbalanced single-center cohort, require further validation in larger prospective studies before clinical application.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Yuan Y, Huang M, Peng J, et al. Whole-lesion histogram analysis of multi-model diffusion-weighted imaging for characterization and molecular classification of breast lesions. Radiol Med. 2025. PMID: 41231330. doi:10.1007/s11547-025-02156-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。