文献速递泌尿生殖妇产影像MR

扩散加权信号强度比值测量预测附件肿块恶性及与ORADS MRI评分比较:简化MRI方案能否准确预测恶性?

Utility of diffusion-weighted signal intensity ratio measurements for predicting malignancy in adnexal mass lesions and its comparison with ORADS MRI scoring: Can an abbreviated MRI protocol predict malignancy accurately?
PubMed 文献 · Clin Radiol · 2025-10-29

回顾性分析184例经组织病理学诊断的卵巢肿瘤MRI,评估扩散加权信号强度比值(DW-SIR)区分良恶性及交界性病变的价值。DW-SIR截断值0.375预测恶性的准确率为68.5%、阳性预测值为73%,较高DW-SIR与较高ORADS评分相关(p<0.001),联合DW-SIR截断值后ORADS 4和5组恶性阳性似然比轻度增加。作者认为DW-SIR可作为提高中间风险ORADS病例判读信心的辅助工具,或在对比剂MRI禁忌时作为独立分诊工具,但需注意其敏感度局限性。

要点

  • DW-SIR截断值0.375预测卵巢肿瘤恶性准确率68.5%、阳性预测值73%。
  • 较高DW-SIR与较高ORADS评分相关(p<0.001)。
  • 联合DW-SIR截断值后ORADS 4和5组恶性阳性似然比轻度增加。

核心结论

  • DW-SIR可作为辅助工具提高中间风险ORADS病例的判读信心,或在对比剂MRI禁忌时作为独立分诊工具,但需注意其敏感度局限性。

研究设计与样本

  • 回顾性分析经组织病理学诊断的卵巢肿瘤MRI研究,共纳入184例,其中良性/交界性74例(40%)、恶性110例(60%),由两组放射科医生分别计算DW-SIR并与ORADS评分进行统计相关性检验。

诊断标准与关键数值

  • 第一轮判读后计算的DW-SIR截断值0.375预测恶性的准确率为68.5%,阳性预测值为73%。
  • 应用DW-SIR截断值后各ORADS评分的恶性阳性预测值增加,尤其在ORADS 3组。
  • 较高DW-SIR值与较高ORADS评分相关(p<0.001)。

临床应用与阅片要点

  • DW-SIR可作为辅助工具提高中间风险ORADS病例的判读信心。
  • 对比剂MRI禁忌时,DW-SIR或可作为独立分诊工具。
  • 使用DW-SIR时需注意其敏感度局限性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess if diffusion-weighted signal intensity ratio (DW-SIR) is a good parameter for differentiating malignant from benign and borderline ovarian lesions.

MATERIALS AND METHODS: The MRI studies of histopathologically diagnosed cases of ovarian tumors were reviewed by two groups of radiologists, both calculating the DW SIR for individual cases. The correlation between the DW SIR and ORADS scoring was tested statistically and the positive likelihood ratio of ORADS scoring for predicting malignancy when used solely as well as in conjunction with DW-SIR was calculated.

RESULTS: A total of 184 cases were included, of which 74 cases were Benign/borderline (40 %) and 110 cases were malignant (60 %). A DW SIR cut off of 0.375 calculated after the first cycle of reading had an accuracy of 68.5 % and positive predictive value (PPV) of 73 % in predicting malignancy. The PPV for malignancy for each ORADS score increased especially in the ORADS 3 group when the DW SIR cut off was applied. Higher DW SIR values were associated with a higher ORADS score (p<0.001). A marginal increase in the positive likelihood ratio for malignancy was observed in the combined ORADS 4 and 5 groups upon using the DW-SIR cut off.

CONCLUSION: DW-SIR can serve as an adjunctive tool to improve confidence in interpreting intermediate-risk ORADS cases or as a standalone triage tool when contrast MRI is contraindicated, keeping in mind its limitations in sensitivity.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Mahmood NS, Al Rashid AA, Ladumor SB, et al. Utility of diffusion-weighted signal intensity ratio measurements for predicting malignancy in adnexal mass lesions and its comparison with ORADS MRI scoring: Can an abbreviated MRI protocol predict malignancy accurately? Clin Radiol. 2025. PMID: 41297156. doi:10.1016/j.crad.2025.107148

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。