文献速递妇产影像腹部MR

基于双参数MRI的列线图鉴别恶性与非典型良性子宫平滑肌肿瘤

Biparametric MRI-based nomogram for differentiating malignant from atypical benign uterine smooth muscle tumors.
PubMed 文献 · Abdom Radiol (NY) · 2025-11-24

回顾性纳入2012年1月至2023年1月因非典型子宫肿块行MRI并手术的77例患者共89个病灶,构建基于双参数MRI的列线图鉴别恶性/潜在恶性平滑肌肿瘤与非典型良性平滑肌瘤。多因素分析显示不规则边缘、T2高信号、DWI高信号及ADC≤0.998×10⁻³ mm²/s为独立预测因子,列线图评分≥132分归为可能恶性,AUC=0.975(95%CI 0.91-0.99),敏感度96.1%、特异度93.6%,观察者间一致性κ=0.72-0.89。

要点

  • 不规则边缘、T2高信号、DWI高信号、ADC≤0.998×10⁻³ mm²/s为恶性独立预测因子。
  • 列线图评分≥132分归为可能恶性,AUC=0.975,敏感度96.1%、特异度93.6%。
  • 观察者间一致性κ=0.72-0.89,提示特征可重复性较好。

核心结论

  • 基于双参数MRI可重复、免对比剂影像特征的列线图有助于准确鉴别子宫平滑肌肿瘤的良恶性,可能指导术前管理,尤其在CE-MRI不可用或禁忌时。

研究设计与样本

  • 回顾性研究,纳入2012年1月至2023年1月因非典型子宫肿块行MRI并后续手术的患者77例共89个病灶(中位年龄45.6岁),使用1.5T或3T扫描仪,序列包括T2加权、扩散加权序列及ADC图,由两名经验丰富的放射科医师评估定性特征和定量平均ADC值,以组织病理学为参考标准。

关键影像表现/征象

  • 不规则边缘为恶性独立预测因子。
  • T2高信号为恶性独立预测因子。
  • DWI高信号为恶性独立预测因子。
  • 低ADC值(≤0.998×10⁻³ mm²/s)为恶性独立预测因子。

诊断标准与关键数值

  • 列线图评分≥132分归类为可能恶性。
  • 列线图模型AUC=0.975(95%CI 0.91-0.99),敏感度96.1%,特异度93.6%。
  • 观察者间一致性κ=0.72-0.89,为中等至优秀。

临床应用与阅片要点

  • 作者认为该列线图工具可能指导术前管理,尤其在CE-MRI不可用或禁忌时。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To develop and validate a biparametric MRI (bpMRI)-based nomogram for distinguishing malignant or potentially malignant uterine smooth muscle tumors from atypical benign leiomyomas.

MATERIALS AND METHODS: In this retrospective study, patients who underwent MRI for atypical uterine masses from January 2012 to January 2023 and subsequently underwent surgery were identified. MRI was performed using 1.5 Tesla or 3 Tesla scanners, including T2-weighted, diffusion-weighted sequences, and ADC maps. Two experienced radiologists evaluated lesions for qualitative features (i.e., T1/ T2 signal intensity, margins, presence of haemorrhage, DWI restriction) and quantitative mean ADC values. Histopathology served as the reference standard. Logistic regression identified significant predictors of malignancy, which were incorporated into a point-based nomogram. Receiver Operating Characteristic (ROC) analysis assessed model performance; interobserver agreement was evaluated using Cohen's kappa.

RESULTS: Eighty-nine lesions from 77 patients (median age, 45.6 years) were included. Malignant and potentially malignant lesions were 26 (30%), and 63 (70%) were benign. On multivariate analysis, irregular margins, hyperintense T2 signal, hyperintense DWI signal, and low ADC values (≤ 0.998 × 10⁻3 mm2/s) were independent predictors of malignancy. These were incorporated into the point-based nomogram. Patients scoring ≥ 132 on the nomogram were classified as likely malignant. The derived nomogram model demonstrated high accuracy (AUC = 0.975; 95% Confidence Interval (CI): 0.91-0.99), with 96.1% sensitivity and 93.6% specificity. Interobserver agreement ranged from substantial to excellent (κ = 0.72-0.89).

CONCLUSION: A biparametric MRI-based nomogram using reproducible, contrast-free imaging features can help accurately differentiate malignant from benign uterine smooth muscle tumors. This tool may guide preoperative management, particularly when CE-MRI is unavailable or contraindicated.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Lakhani A, Reddy H, Augustine A, et al. Biparametric MRI-based nomogram for differentiating malignant from atypical benign uterine smooth muscle tumors. Abdom Radiol (NY). 2025. PMID: 41276641. doi:10.1007/s00261-025-05298-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。