文献速递泌尿生殖腹部USCTMR

标准超声采用超声版Bosniak分类与CT/MRI比较评估囊性肾肿块可行性的多中心研究

Evaluating the Feasibility of Standard Ultrasound in the Bosniak Classification of Cystic Renal Masses Compared with Computed Tomography/Magnetic Resonance Imaging: A Multicenter Study.
PubMed 文献 · Ultrasound Med Biol · 2025-11-13

多中心研究纳入603个囊性肾肿块,用超声版Bosniak分类与CT/MRI Bosniak分类对比,以≥III类为恶性截断值。超声与CT/MRI的AUC分别为0.78和0.82,敏感度77%对86%、特异度79%对78%,差异无统计学意义(p=0.17)。超声分类可重复且能识别恶性,可作为低成本替代方案。

要点

  • 超声版Bosniak分类与CT/MRI分类在68%的病灶中一致(κ=0.75),19.5%的病灶超声评分更高。
  • 以≥III类为恶性截断值,超声AUC 0.78、敏感度77%、特异度79%,与CT/MRI无显著差异(p=0.17)。
  • 高年资读者间一致性优秀(κ=0.88),低年资读者一致性中等(κ=0.66)。

核心结论

  • 超声版Bosniak分类可重复且能有效识别囊性肾肿块中的恶性病变,可作为增强检查模式的低成本替代方案,在资源有限环境中尤为重要。

研究设计与样本

  • 多中心研究,2016年7月至2022年6月,纳入6个中心经病理证实或随访≥3年的囊性肾肿块603个(239个病理证实,364个随访充分),由4名不同经验水平的读者用超声版Bosniak分类评估,2名高年资读者共识判读,同时有CT/MRI的病灶由盲法放射科医师重新行CT/MRI Bosniak分类。

诊断标准与关键数值

  • 以Bosniak分类≥III类为恶性截断值,超声AUC 0.78、敏感度77%、特异度79%;CT/MRI AUC 0.82、敏感度86%、特异度78%;两者差异无统计学意义(p=0.17)。超声与CT/MRI分类一致率68%(κ=0.75),19.5%的病灶超声评分更高;低年资读者与共识一致性最高κ=0.77,高年资读者最高κ=0.89;读者间变异低年资κ=0.66、高年资κ=0.88。

临床应用与阅片要点

  • 作者认为超声版Bosniak分类可重复且能有效识别囊性肾肿块中的恶性病变,可作为增强检查模式的低成本替代方案,在资源有限环境中尤为重要。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the diagnostic performance of standard ultrasound (US) using a US-adapted Bosnian classification for characterizing cystic renal masses (CRMs) compared with computed tomography/magnetic resonance imaging (CT/MRI) as the current standard.

METHODS: From July 2016 to June 2022, pathology-proven CRMs and CRMs with ≥3 y of follow-up from six centers were reviewed. Four readers with varying levels of expertise in US categorized CRMs using a US-based Bosnian classification, followed by a consensus reading by two high-level readers. For CRMs with concurrent CT/MRI, the CT/MRI Bosniak classification was performed again by a blinded radiologist. With a cut-off category of ≥III as malignancy, diagnostic performance was compared using receiver operating characteristic curve analysis. Inter-modality agreement and inter-observer variability were statistically evaluated.

RESULTS: A total of 603 CRMs graded to US Bosniak I, II, IIF, III and IV were analyzed, including 239 pathology-proven lesions and 364 lesions with adequate follow-up. The area under curve was 0.78 for US and 0.82 for CT/MRI, with a sensitivity of 77% versus 86% and a specificity of 79% versus 78%, respectively, showing no significant differences (p = 0.17). US and CT/MRI classifications matched in 68% (substantial agreement, kappa [κ] = 0.75), with US leading to higher scores in 19.5%. Comparison with reader consensus was substantial (highest κ = 0.77) for low-level readers and excellent (highest κ = 0.89) for high-level readers. Inter-observer variability showed substantial agreement (κ = 0.66) in low-level readers and excellent agreement (κ = 0.88) in high-level readers.

CONCLUSION: US-based Bosniak classification is reproducible and effective for identifying malignancy among CRMs, offering a lower-cost alternative to contrast-enhanced modalities, which is particularly important in resource-limited care settings.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. He F, Yuan J, Chen L, et al. Evaluating the Feasibility of Standard Ultrasound in the Bosniak Classification of Cystic Renal Masses Compared with Computed Tomography/Magnetic Resonance Imaging: A Multicenter Study. Ultrasound Med Biol. 2025. PMID: 41238458. doi:10.1016/j.ultrasmedbio.2025.10.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。