标准超声采用超声版Bosniak分类与CT/MRI比较评估囊性肾肿块可行性的多中心研究
多中心研究纳入603个囊性肾肿块,用超声版Bosniak分类与CT/MRI Bosniak分类对比,以≥III类为恶性截断值。超声与CT/MRI的AUC分别为0.78和0.82,敏感度77%对86%、特异度79%对78%,差异无统计学意义(p=0.17)。超声分类可重复且能识别恶性,可作为低成本替代方案。
要点
- 超声版Bosniak分类与CT/MRI分类在68%的病灶中一致(κ=0.75),19.5%的病灶超声评分更高。
- 以≥III类为恶性截断值,超声AUC 0.78、敏感度77%、特异度79%,与CT/MRI无显著差异(p=0.17)。
- 高年资读者间一致性优秀(κ=0.88),低年资读者一致性中等(κ=0.66)。
核心结论
- 超声版Bosniak分类可重复且能有效识别囊性肾肿块中的恶性病变,可作为增强检查模式的低成本替代方案,在资源有限环境中尤为重要。
研究设计与样本
- 多中心研究,2016年7月至2022年6月,纳入6个中心经病理证实或随访≥3年的囊性肾肿块603个(239个病理证实,364个随访充分),由4名不同经验水平的读者用超声版Bosniak分类评估,2名高年资读者共识判读,同时有CT/MRI的病灶由盲法放射科医师重新行CT/MRI Bosniak分类。
诊断标准与关键数值
- 以Bosniak分类≥III类为恶性截断值,超声AUC 0.78、敏感度77%、特异度79%;CT/MRI AUC 0.82、敏感度86%、特异度78%;两者差异无统计学意义(p=0.17)。超声与CT/MRI分类一致率68%(κ=0.75),19.5%的病灶超声评分更高;低年资读者与共识一致性最高κ=0.77,高年资读者最高κ=0.89;读者间变异低年资κ=0.66、高年资κ=0.88。
临床应用与阅片要点
- 作者认为超声版Bosniak分类可重复且能有效识别囊性肾肿块中的恶性病变,可作为增强检查模式的低成本替代方案,在资源有限环境中尤为重要。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the diagnostic performance of standard ultrasound (US) using a US-adapted Bosnian classification for characterizing cystic renal masses (CRMs) compared with computed tomography/magnetic resonance imaging (CT/MRI) as the current standard.
METHODS: From July 2016 to June 2022, pathology-proven CRMs and CRMs with ≥3 y of follow-up from six centers were reviewed. Four readers with varying levels of expertise in US categorized CRMs using a US-based Bosnian classification, followed by a consensus reading by two high-level readers. For CRMs with concurrent CT/MRI, the CT/MRI Bosniak classification was performed again by a blinded radiologist. With a cut-off category of ≥III as malignancy, diagnostic performance was compared using receiver operating characteristic curve analysis. Inter-modality agreement and inter-observer variability were statistically evaluated.
RESULTS: A total of 603 CRMs graded to US Bosniak I, II, IIF, III and IV were analyzed, including 239 pathology-proven lesions and 364 lesions with adequate follow-up. The area under curve was 0.78 for US and 0.82 for CT/MRI, with a sensitivity of 77% versus 86% and a specificity of 79% versus 78%, respectively, showing no significant differences (p = 0.17). US and CT/MRI classifications matched in 68% (substantial agreement, kappa [κ] = 0.75), with US leading to higher scores in 19.5%. Comparison with reader consensus was substantial (highest κ = 0.77) for low-level readers and excellent (highest κ = 0.89) for high-level readers. Inter-observer variability showed substantial agreement (κ = 0.66) in low-level readers and excellent agreement (κ = 0.88) in high-level readers.
CONCLUSION: US-based Bosniak classification is reproducible and effective for identifying malignancy among CRMs, offering a lower-cost alternative to contrast-enhanced modalities, which is particularly important in resource-limited care settings.
引用
- He F, Yuan J, Chen L, et al. Evaluating the Feasibility of Standard Ultrasound in the Bosniak Classification of Cystic Renal Masses Compared with Computed Tomography/Magnetic Resonance Imaging: A Multicenter Study. Ultrasound Med Biol. 2025. PMID: 41238458. doi:10.1016/j.ultrasmedbio.2025.10.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。