文献速递泌尿生殖腹部MR

整合瘤内栖息地与瘤周影像组学的Transformer模型用于检测前列腺癌盆腔淋巴结转移

A Transformer-Based Model Integrating Intratumoral Habitats and Peritumoral Radiomics for Detecting Pelvic Lymph Node Metastasis in Prostate Cancer.
PubMed 文献 · Acad Radiol · 2025-11-20

本研究基于四中心867例前列腺癌患者回顾性队列,构建Transformer融合模型整合瘤内栖息地、最佳瘤周及临床变量,用于术前无创预测盆腔淋巴结转移。融合模型在各队列AUC达0.824-0.917,敏感度0.869-0.939,校准良好,决策曲线分析显示净临床获益更优。

要点

  • 瘤内栖息地模型AUC 0.788-0.834,优于所有单模态模型及两位放射科医师。
  • 6 mm瘤周模型AUC 0.729-0.835,为最佳瘤周环。
  • Transformer融合模型AUC 0.824-0.917,敏感度0.869-0.939。

核心结论

  • 基于Transformer的融合模型对盆腔淋巴结转移提供准确、敏感且可解释的预测,减少漏诊和过度诊断,支持个体化临床决策。

研究设计与样本

  • 回顾性队列纳入四中心867例接受根治性前列腺切除术及盆腔淋巴结清扫的前列腺癌患者,分为训练集437例、内部验证集125例和外部测试集305例。

关键影像表现/征象

  • 从肿瘤栖息地及瘤周环(3/6/9 mm)提取影像组学特征。
  • 构建单模态模型,并用Transformer架构融合栖息地、最佳瘤周及临床变量。
  • 通过SHAP值解释特征重要性。

诊断标准与关键数值

  • 栖息地模型AUC 0.788-0.834,优于所有单模态模型及两位放射科医师(5年以上和10年以上经验)。
  • 6 mm瘤周模型AUC 0.729-0.835,为最佳瘤周环。
  • 融合模型在各队列AUC 0.824-0.917,准确度0.797-0.840,敏感度0.869-0.939,校准良好(P > 0.05)。
  • 决策曲线分析证实融合模型净临床获益更大。
  • 模型性能在T分期和Gleason分级分组亚组中保持稳健。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Pelvic lymph node metastasis (PLNM) is a critical factor in prostate cancer (PCa) treatment decisions. Current imaging and clinical nomograms remain limited by suboptimal sensitivity and frequent underdiagnosis. This study aimed to develop and validate a transformer-based model integrating intratumoral habitat and peritumoral radiomics features for noninvasive preoperative PLNM prediction.

METHODS: A retrospective cohort of 867 PCa patients from four centers who underwent radical prostatectomy and pelvic lymph node dissection was enrolled. Patients were split into training (n = 437), internal validation (n = 125), and external test (n = 305) cohorts. Radiomic features were extracted from tumor habitats and peritumoral rings (3/6/9 mm). Unimodal models were constructed and fused using a transformer architecture that combined habitat, optimal peritumoral, and clinical variables. Performance was assessed using AUC, calibration curves, and decision curve analysis (DCA). Feature importance was interpreted via SHAP values.

RESULTS: The habitat model outperformed all unimodal models (AUC 0.788-0.834) and both radiologists (5+ and 10+ years' experience), followed by the 6-mm peritumoral model (AUC: 0.729-0.835). The fusion model achieved superior performance across cohorts (AUC: 0.824-0.917; accuracy: 0.797-0.840; sensitivity: 0.869-0.939) and demonstrated good calibration (P > 0.05). DCA confirmed greater net clinical benefit. Performance remained robust across T-stage and Gleason Grade Group subgroups.

CONCLUSION: The transformer-based fusion model offers accurate, sensitive, and interpretable prediction of PLNM, reducing underdiagnosis and overdiagnosis and supporting individualized clinical decision-making.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Cao J, Feng X, Liu R, et al. A Transformer-Based Model Integrating Intratumoral Habitats and Peritumoral Radiomics for Detecting Pelvic Lymph Node Metastasis in Prostate Cancer. Acad Radiol. 2025. PMID: 41266221. doi:10.1016/j.acra.2025.10.059

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。