深度学习加速HASTE-FS用于胰腺囊性病变监测的可行性:与传统HASTE及MRCP的比较
回顾性纳入91例接受3T腹部MRI(含深度学习重建HASTE-FS、传统HASTE及MRCP)的患者,由3名腹部放射科医生评分。DL HASTE-FS在胰管边缘锐利度、囊灶 conspicuousness及囊壁/分隔锐利度上优于传统HASTE,但在胰腺边缘锐利度和胰周血管清晰度上传统HASTE更优;DL HASTE-FS被认为可替代MRCP的病例比例高于传统HASTE(83% vs 48%)。
要点
- DL HASTE-FS的囊灶 conspicuousness 和囊壁/分隔锐利度评分均高于传统HASTE(4.4 vs 3.9;4.3 vs 3.7,p<.001)。
- 传统HASTE的胰腺边缘锐利度和胰周血管清晰度评分高于DL HASTE-FS(4.2 vs 3.8;4.2 vs 3.4,p<.001)。
- DL HASTE-FS被认为可替代MRCP的病例比例高于传统HASTE(83% vs 48%,p<.001)。
核心结论
- DL HASTE-FS在胰腺囊性病变检出和定性方面优于传统HASTE,在PCL监测背景下可作为3D MRCP的合适替代方案,可能减少检查时间和成本。
研究设计与样本
- 回顾性研究,纳入2023年8月2日至2023年10月3日期间连续91例接受3T腹部MRI(含MRCP方案、DL HASTE-FS及传统HASTE)的患者,由3名腹部放射科医生采用5分Likert量表评分,并对70个预选索引PCL评估囊灶特征、诊断侧支型IPMN的信心及DL HASTE-FS替代MRCP的适宜性。
关键影像表现/征象
- DL HASTE-FS的胰管边缘锐利度评分高于传统HASTE(4.1 vs 3.9,p=.004)。
- DL HASTE-FS的胰管可见度评分高于MRCP(2.0 vs 1.9,p=.04)。
- DL HASTE-FS的囊灶 conspicuousness 评分高于传统HASTE(4.4 vs 3.9,p<.001)。
- DL HASTE-FS的囊壁及内部分隔锐利度评分高于传统HASTE(4.3 vs 3.7,p<.001)。
- 传统HASTE的胰腺边缘锐利度评分高于DL HASTE-FS(4.2 vs 3.8,p<.001),胰周血管清晰度评分也高于DL HASTE-FS(4.2 vs 3.4,p<.001)。
诊断标准与关键数值
- 对70个预选索引PCL,读者在DL HASTE-FS上可视化的PCL数量多于传统HASTE,诊断侧支型IPMN的信心评分也高于传统HASTE(3.6 vs 3.4,p<.001)。
- DL HASTE-FS被认为可替代MRCP的病例比例高于传统HASTE(83% vs 48%,p<.001)。
临床应用与阅片要点
- DL HASTE-FS在囊灶 conspicuousness 及囊壁/分隔显示上优于传统HASTE,可用于PCL检出和定性。
- DL HASTE-FS在胰管边缘及可见度方面表现较好,83%的病例被认为可替代MRCP进行PCL监测。
- 传统HASTE在胰腺边缘锐利度和胰周血管清晰度上更优,阅片时需结合序列特点综合判断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Pancreatic cystic lesions (PCL) commonly undergo surveillance using MRI with MR cholangiopancreatography (MRCP). Our objective is to compare the performance of a single-shot fat-saturated T2-weighted technique with deep-learning reconstruction (DL HASTE-FS) to a conventional T2-weighted Half fourier Single-shot Turbo spin-Echo (HASTE) sequence and to MRCP for the purpose of PCL detection, characterization, and surveillance.
METHODS: In this retrospective study, 91 consecutive patients underwent 3T abdominal MRI with MRCP protocol including DL HASTE-FS and conventional HASTE between 8/2/2023 and 10/3/2023. Three abdominal radiologists rated overall and lesion-specific image quality on a 5-point Likert scale, including pancreatic margin and duct sharpness, and PCL conspicuity. A subset of 70 preselected index PCLs were evaluated for cyst features, confidence of diagnosing side-branch IPMN, and suitability of DL HASTE-FS in replacing MRCP for PCL surveillance.
RESULTS: DL HASTE-FS received higher scores for pancreatic duct border sharpness (4.1 vs. 3.9; p = .004), pancreatic duct visibility compared to MRCP (2.0 vs. 1.9; p = .04), cyst conspicuity (4.4 vs. 3.9; p < .001), and sharpness of cyst wall and internal septations (4.3 vs. 3.7; p < .001) compared to conventional HASTE. In contrast, conventional HASTE received higher scores for pancreatic margin sharpness (4.2 vs. 3.8; p < .001) and peripancreatic vessel clarity (4.2 vs. 3.4; p < .001). For the 70 preselected index PCLs, readers visualized more PCLs and had higher confidence in diagnosing SB-IPMN on DL HASTE-FS than on conventional HASTE (3.6 vs. 3.4; p < .001). Finally, DL HASTE-FS was deemed a suitable replacement to MRCP for more cases than conventional HASTE (83% vs. 48%; p < .001).
CONCLUSION: DL HASTE-FS outperforms conventional HASTE for PCL detection and characterization, and is a suitable alternative to 3D MRCP in the context of PCL surveillance, potentially reducing exam time and cost.
引用
- Le L, Ginocchio LA, Kim S, et al. Feasibility of deep learning-accelerated HASTE-FS for pancreatic cystic lesion surveillance: comparison with conventional HASTE and MRCP. Abdom Radiol (NY). 2025. PMID: 41251737. doi:10.1007/s00261-025-05265-4