沸腾组织碎化术作为无创非热疗方法治疗人结肠癌肿瘤:一项离体概念验证研究
研究先以剪切波弹性成像测量尸检人乙状结肠癌样本的杨氏模量为38±10 kPa,再用2 MHz 9环阵列在B超引导下对离体样本行沸腾组织碎化术(BH)三维网格消融。B超实时引导成功,治疗区BH中呈高回声、治疗后呈低回声;组织学证实病灶内细胞碎裂、间质及胶原纤维破坏,病灶外黏液性结肠癌完整。作者认为离体初步研究显示BH用于结直肠癌及转移灶无创非热超声引导治疗具有潜力。
要点
- 尸检人乙状结肠癌样本剪切波弹性成像杨氏模量为38±10 kPa,与直肠腺癌临床值相符。
- B超可实时引导BH:治疗区BH过程中呈高回声,治疗后呈低回声。
- 组织学示BH病灶内细胞碎裂、间质损伤伴胶原纤维破坏,病灶外黏液性结肠癌完整。
核心结论
- 这项离体初步研究显示,沸腾组织碎化术(BH)有望成为结直肠癌及其转移灶的无创、非热、超声引导治疗方法。
研究设计与样本
- 离体概念验证研究,采用尸检人乙状结肠癌样本,先用剪切波弹性成像测杨氏模量,再用2 MHz 9环阵列(聚焦角67.5°)在B超引导下按三维网格(2个横向层、每层5×5焦点、间距1 mm)行BH消融,并以B超、苏木精-伊红和马松三色染色组织学分析病灶。
关键影像表现/征象
- BH治疗区在BH过程中呈高回声,治疗后呈低回声。
- 组织学示BH病灶内为碎裂细胞和受损间质伴胶原纤维破坏,病灶外黏液性结肠癌完整。
诊断标准与关键数值
- 尸检人乙状结肠癌样本剪切波弹性成像杨氏模量为38±10 kPa。
- 每个焦点接受150个脉冲,脉宽1 ms,峰值正/负压及冲击振幅P+/P-/As=91/-13/78 MPa,脉冲内声功率W0=125.5 W、初始强度I0=2.7 W/cm2,脉冲间隔0.1 s(占空比1%)。
局限性
- 原文为离体初步研究(ex vivo pilot study),样本为尸检人乙状结肠癌,原文未报告样本例数。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Colorectal cancer (CRC) is the third most common cancer globally and is frequently diagnosed at metastatic stages. As an alternative to the current standard of care, a novel high-intensity-focused ultrasound (HIFU)-based boiling histotripsy (BH) method has the potential to provide an ultrasound (US)-guided approach for non-invasive mechanical fractionation of CRC metastases and enhancement of anti-tumor immune response for inoperable primary CRC.
METHODS: Young's modulus of the autopsy human sigmoid colon cancer was first measured using shear wave elastography. Volumetric BH lesion was then produced in the cancer sample ex vivo using a 2-MHz 9-element annular array (67.5° focusing angle) targeting a 3D-grid (5 × 5 foci across 2 transverse layers with 1-mm spacing) under B-mode US guidance. Each focus received 150 pulses of 1-ms duration (peak positive/negative pressures and shock amplitude P+/P/As = 91/-13/78 MPa, acoustic power and initial intensity within the pulse W0 = 125.5 W and I0 = 2.7 W/cm2) delivered at 0.1-s intervals (1% duty cycle). The obtained lesion was analyzed via B-mode imaging and histologically with hematoxylin-eosin and Masson's trichrome.
RESULTS: Young's modulus of the autopsy CRC sample was 38 ± 10 kPa and aligned with clinical values for rectal adenocarcinomas. BH treatment was successfully guided in real-time using B-mode US: the treated area was hyperechoic during BH and hypoechoic post-treatment. Histology confirmed the presence of intact mucinous colon carcinoma outside the BH lesion, and fractionated cells and damaged stroma with disrupted collagen fibers within the lesion.
CONCLUSIONS: This ex vivo pilot study demonstrates the potential of BH for non-invasive non-thermal US-guided treatment for CRC and metastases.
引用
- Ponomarchuk E, Tsysar S, Kadrev A, et al. Boiling Histotripsy as a Non-Invasive Non-Thermal Approach for Treatment of Human Colon Cancer Tumors: An Ex Vivo Proof-of-Concept. J Ultrasound Med. 2025. PMID: 41277523. doi:10.1002/jum.70137
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。