文献速递腹部CTMR

在超重或肥胖人群中用快速千伏切换双能CT定量肝脏脂肪变性

Quantification of liver steatosis using rapid kilovoltage-switching dual-energy computed tomography in individuals who are overweight or obese.
PubMed 文献 · Eur J Radiol · 2025-11-17

本研究为回顾性单中心研究,纳入2019年4月至2021年8月间接受DECT和MRI检查的超重或肥胖者130例,以MRI-PDFF为参考标准将肝脂肪含量分为四组。DECT-FVF与74-keV CT值均与MRI-PDFF高度相关,识别轻度及以上脂肪变性的最佳阈值存在性别差异,对应AUC为0.92/0.94(全体)、0.95/0.98(男性)、0.86/0.89(女性)。

要点

  • DECT-FVF与74-keV CT值均可有效定量超重或肥胖者的肝脂肪变性。
  • 识别轻度及以上脂肪变性时,男性最佳DECT-FVF阈值为3.8%、CT值为56.5 HU。
  • 女性最佳DECT-FVF阈值为2.1%、CT值为56.3 HU,与男性阈值不同。

核心结论

  • DECT-FVF和74-keV CT值能有效定量超重或肥胖者的肝脂肪变性,应考虑性别特异性诊断阈值以实现二分类肝脂肪变性分级的准确分层。

研究设计与样本

  • 回顾性单中心研究,纳入2019年4月至2021年8月间预筛或入组限时进食研究的超重或肥胖者130例(中位年龄31.2岁,四分位距12.5岁;男性69例),均接受DECT和MRI检查,以MRI-PDFF为参考标准将肝脂肪含量分为四组。

诊断标准与关键数值

  • DECT-FVF与MRI-PDFF的Spearman相关系数为0.933(男性0.963,女性0.843);74-keV CT值与MRI-PDFF的相关系数为-0.954(男性-0.977,女性-0.895);识别轻度及以上脂肪变性的最佳阈值:全体DECT-FVF 5.3%、CT值55.9 HU(AUC 0.92/0.94),男性DECT-FVF 3.8%、CT值56.5 HU(AUC 0.95/0.98),女性DECT-FVF 2.1%、CT值56.3 HU(AUC 0.86/0.89)。

临床应用与阅片要点

  • 作者认为应考虑性别特异性DECT诊断阈值,以实现对二分类肝脂肪变性分级的准确分层。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To validate the capability of dual-energy computed tomography (DECT) to quantify liver fat in individuals who are overweight or obese and assess the sex-based differences.

METHODS: This retrospective, single-center study involved individuals who were pre-screened or enrolled in a time-restricted eating study between April 2019 and August 2021 and underwent both DECT and MRI. Participants were stratified into four groups according to the hepatic fat content quantified using the MRI-proton density fat fraction (MRI-PDFF). Receiver operating characteristic curves for the ability of DECT-fat volume fraction (DECT-FVF) or CT values at 74-keV to grade hepatic steatosis were plotted and optimal thresholds determined.

RESULTS: A total of 130 participants who were overweight or obese (median age: 31.2 years [interquartile range, 12.5 years]; men, n = 69) were enrolled in the study. Both DECT-FVF and CT values at 74-keV were highly correlated with MRI-PDFF (Spearman's r = 0.933 [0.963 for males, 0.843 for females] and - 0.954 [-0.977 for males, -0.895 for females], respectively). The optimal cutoff DECT-FVF/CT values at 74-keV for identifying participants with mild or greater steatosis were 5.3 %/55.9 HU for all participants, 3.8 %/56.5 HU for males, and 2.1 %/56.3 HU for females, with corresponding areas under the curve values of 0.92/0.94, 0.95/0.98, and 0.86/0.89.

CONCLUSIONS: DECT-FVF and CT values at 74-keV image can effectively quantify hepatic steatosis in individuals who are overweight or obese. Sex-specific diagnostic thresholds for DECT should be considered to achieve accurate stratification of dichotomized hepatic steatosis grading.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hou M, Xu J, Chen G, et al. Quantification of liver steatosis using rapid kilovoltage-switching dual-energy computed tomography in individuals who are overweight or obese. Eur J Radiol. 2025. PMID: 41275633. doi:10.1016/j.ejrad.2025.112550

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。