文献速递儿科影像腹部MRUS

超声与磁共振成像评估儿童克罗恩病:MaRIA评分和IBUS-SAS与内镜下疾病活动度的相关性及最佳截断值

Ultrasound and MRI for pediatric Crohn's disease assessment: correlations of the MaRIA score and IBUS-SAS with endoscopic disease activity and optimal cutoff values.
PubMed 文献 · Abdom Radiol (NY) · 2025-11-21

该回顾性分析纳入2017至2022年浙江大学医学院附属儿童医院48例新发克罗恩病患儿,评估MaRIA与IBUS-SAS同CDEIS的相关性。总MaRIA与总IBUS-SAS均与CDEIS正相关(r=0.334和r=0.328,均p<0.05);结直肠区MaRIA与CDEIS相关系数0.345(P<0.05),IBUS-SAS与CDEIS相关系数0.501(P<0.05),回肠末端两者与CDEIS均无显著相关。总IBUS-SAS预测内镜下中度活动(CDEIS≥9)的AUC为0.655(95%CI 0.496-0.814),最佳截断值55.5。

要点

  • 总IBUS-SAS预测内镜下中度活动(CDEIS≥9)的最佳截断值为55.5,AUC 0.655(95%CI 0.496-0.814)。
  • 结直肠区IBUS-SAS与CDEIS相关性(r=0.501,P<0.05)高于MaRIA(r=0.345,P<0.05)。
  • 回肠末端IBUS-SAS和MaRIA与CDEIS均无显著相关。

核心结论

  • 在新发儿童克罗恩病中,MaRIA和IBUS-SAS均与CDEIS相关;IBUS-SAS>55.5提示中度活动;当MRE不可行时,IUS可作为MRE的替代方法评估疾病活动度。

研究设计与样本

  • 回顾性分析,纳入2017至2022年浙江大学医学院附属儿童医院48例新发克罗恩病患儿,均接受IUS、MRE和结肠镜检查;按肠段评估MaRIA、IBUS-SAS和CDEIS,分别对总分(所有肠段)、回肠末端评分(回肠末端肠段)和结肠评分(所有结直肠肠段)进行相关性分析,非正态分布数据采用Spearman秩相关系数。

诊断标准与关键数值

  • 总MaRIA与CDEIS正相关(r=0.334,p<0.05),总IBUS-SAS与CDEIS正相关(r=0.328,p<0.05)。
  • 结直肠区MaRIA与CDEIS的Spearman秩相关系数为0.345(P<0.05),IBUS-SAS与CDEIS的Spearman秩相关系数为0.501(P<0.05)。
  • 回肠末端IBUS-SAS和MaRIA评分与CDEIS值均无显著相关。
  • 总IBUS-SAS验证中AUC为0.655(95%CI 0.496-0.814),预测内镜下中度活动性疾病(CDEIS值≥9)的最佳截断值为55.5。

临床应用与阅片要点

  • IBUS-SAS>55.5提示内镜下中度活动(CDEIS≥9)。
  • 当MRE不可行时,IUS可作为MRE的替代方法评估疾病活动度。
  • 结直肠区IBUS-SAS与CDEIS相关性较好(r=0.501),回肠末端两者与CDEIS均无显著相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess transmural damage in Crohn's disease (CD), magnetic resonance enterography (MRE, scored by the Magnetic Resonance Index of Activity, MaRIA) and intestinal ultrasound (IUS, scored by the International Bowel Ultrasound Segmental Activity Score, IBUS-SAS) are used. This study examined their correlation with the Crohn's Disease Endoscopic Index of Severity (CDEIS) in children with CD.

METHODS: This was a retrospective analysis of children with new-onset CD who were treated from 2017 to 2022 at Zhejiang University Children's Hospital. The patients underwent IUS, MRE, and colonoscopy. MaRIA, IBUS-SAS, and CDEIS were assessed across intestinal segments. Correlation analyses were performed separately for the total score (all segments), as well as the terminal ileum score (terminal ileum segments) and the colon score (all colorectal segments). Nonnormally distributed data were analysed using Spearman's rank correlation coefficient.

RESULTS: Forty-eight children were included in this study. The total MaRIA and total IBUS-SAS scores were positively correlated with the CDEIS value (r = 0.334 and r = 0.328, both p < 0.05). In the colorectal region, the Spearman's rank correlation coefficient between the MaRIA score and the CDEIS value was 0.345 (P < 0.05), and that between the IBUS-SAS score and the CDEIS value was 0.501 (P < 0.05). However, in the terminal ileum, neither the IBUS-SAS nor the MaRIA score was significantly correlated with the CDEIS value. In the validation of the total IBUS-SAS, the AUC was 0.655 (95% CI 0.496-0.814), with an optimal cutoff value to predict endoscopically moderate active disease (CDEIS value ≥ 9) of 55.5.

CONCLUSIONS: Both the MaRIA and the IBUS-SAS correlate with CDEIS in new-onset pediatric CD. IBUS-SAS > 55.5 indicates moderate activity. IUS can serve as an alternative to MRE for disease activity assessment when MRE is not viable.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Yu Y, Xu B, Chen J, et al. Ultrasound and MRI for pediatric Crohn's disease assessment: correlations of the MaRIA score and IBUS-SAS with endoscopic disease activity and optimal cutoff values. Abdom Radiol (NY). 2025. PMID: 41269270. doi:10.1007/s00261-025-05274-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。