动态对比增强MRI中全自动多序列局灶性肝脏病灶检测与对齐
回顾性纳入三家医院2020年2月至2022年8月的477例患者,验证人工智能在多序列动态对比增强MRI中全自动检测和对齐局灶性肝脏病灶的性能。AI检测敏感度在病灶水平为0.990、患者水平为0.997,均高于放射科医师的0.607和0.920;AI辅助使放射科医师病灶水平敏感度从0.607提升至0.718(p < 0.001)。
要点
- AI在病灶水平检测敏感度为0.990(95% CI: 0.984-0.994),患者水平为0.997(0.985-1.000)。
- 放射科医师病灶水平敏感度为0.607(0.581-0.631),患者水平为0.920(0.886-0.943)。
- AI辅助将放射科医师病灶水平敏感度从0.607提升至0.718(p < 0.001)。
核心结论
- AI可在九个DCE-MRI序列上全自动检测并对齐局灶性肝脏病灶,检测敏感度高于放射科医师并能提升放射科医师的敏感度。
研究设计与样本
- 多读者、多病例的回顾性研究,纳入三家医院2020年2月至2022年8月的477例患者数据,以AI辅助的高年资放射科医师检测结果为参考标准,在病灶水平和患者水平分析AI、放射科医师及AI辅助放射科医师的检测性能。
诊断标准与关键数值
- AI检测局灶性肝脏病灶的敏感度在病灶水平为0.990(95% CI: 0.984-0.994),在患者水平为0.997(0.985-1.000)。
- 放射科医师检测局灶性肝脏病灶的敏感度在病灶水平为0.607(0.581-0.631),在患者水平为0.920(0.886-0.943)。
- AI辅助放射科医师后病灶水平检测敏感度从0.607(0.581-0.631)提升至0.718(0.695-0.740)(p < 0.001),患者水平准确度为0.904(0.875-0.930)。
- 九个DCE-MRI序列中,1395/1532(91.1%)正确检测的病灶实现了正确对齐。
- 按病灶大小(< 20 mm vs ≥ 20 mm)和病灶数目(1个、2-5个、≥ 6个)分亚组,AI检测敏感度均持续超过0.982。
临床应用与阅片要点
- AI可辅助放射科医师提升DCE-MRI上局灶性肝脏病灶的检测敏感度,并展示出跨九个序列的高对齐能力。
- AI在检测和显示局灶性肝脏病灶方面表现出较强稳健性,可能成为放射科医师阅读DCE-MRI的有价值工具。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To validate an artificial intelligence (AI) method for fully automated detection and alignment of focal liver lesions (FLLs) in multi-sequence dynamic contrast-enhanced MRI (DCE-MRI).
MATERIALS AND METHODS: Retrospective patient data from three hospitals were included from February 2020 to August 2022. A multi-reader, multi-case analysis was conducted, using the AI-assisted senior radiologists' detection results as the reference. The performance of AI, radiologists, and AI-assisted radiologists in detecting FLLs was analyzed at the lesion and patient levels. The senior radiologists validated the AI detection results for the same lesion across the nine different DCE-MRI sequences. The subgroup analyses evaluated detection sensitivity based on lesion size (< 20 mm vs ≥ 20 mm) and lesion number (1, 2-5, and ≥ 6 lesions).
RESULTS: A total of 477 patients (median age 59 years, IQR 48-68 years) were included. The AI correctly detected 1532 FLLs with sensitivities of 0.990 (95% CI: 0.984-0.994) and 0.997 (0.985-1.000) at the lesion and patient levels, respectively. Radiologists showed detection sensitivities of 0.607 (0.581-0.631) and 0.920 (0.886-0.943), respectively. The AI-assisted radiologists significantly improved detection sensitivity from 0.607 (0.581-0.631) to 0.718 (0.695-0.740) at the lesion level (p < 0.001) and achieved an accuracy of 0.904 (0.875-0.930) at the patient level. Across nine DCE-MRI sequences, 1395/1532 (91.1%) correctly detected lesions were correctly aligned. The AI performed well, with detection sensitivity consistently exceeding 0.982 in all subgroups of lesion size and number.
CONCLUSION: AI enables fully automated detection and alignment of FLLs in DCE-MRI across nine MRI sequences.
KEY POINTS: Question Current manual reading of DCE-MRI to detect FLLs is time-consuming and error-prone. Findings The AI system outperformed radiologists in detecting FLLs and improved the sensitivity of radiologists while maintaining precise cross-sequence alignment. Clinical relevance AI can assist radiologists in improving FLLs detection on DCE-MRI, demonstrating high alignment capability across nine sequences. Since AI has exhibited strong robustness in detecting and displaying FLLs, it may serve as a valuable tool for radiologists in reading DCE-MRI.
引用
- Zhang L, Wang L, Zhang Y, et al. Fully automated multi-sequence detection and alignment of focal liver lesions in dynamic contrast-enhanced MRI. Eur Radiol. 2025. PMID: 41175201. doi:10.1007/s00330-025-12055-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。