文献速递腹部技术与安全CT

CT结肠成像评估内脏肥胖:超越结直肠筛查的临床效用

CT colonography for assessing visceral obesity: clinical utility beyond colorectal screening.
PubMed 文献 · Abdom Radiol (NY) · 2025-11-22

本研究回顾性纳入58例在30天内同时接受腹部CT和CTC的患者,比较CTC衍生的内脏脂肪面积(VFA)、BMI和腰围对内脏肥胖的诊断效能,并构建回归模型从CTC测量值估算CT衍生的VFA。CTC衍生的VFA诊断效能最高(敏感度0.90、特异度0.93),多切片模型较单切片模型进一步降低MAE(19.76 vs 16.54 cm²,P=0.013)。

要点

  • CTC衍生的VFA诊断内脏肥胖的敏感度0.90、特异度0.93,优于BMI和腰围。
  • 与CT相比,CTC测量的腰围更大(89.9 vs 87.5 cm,P<0.001),VFA更低(96.0 vs 110.3 cm²,P=0.005)。
  • 多切片模型较单切片模型降低MAE(19.76 vs 16.54 cm²,P=0.013)。

核心结论

  • CTC衍生的VFA是识别内脏肥胖的可行指标,可能提供不增加辐射暴露或成本的二次诊断资源;多切片模型较单切片模型预测准确性更高。

研究设计与样本

  • 回顾性纳入58例在30天内同时接受腹部CT和CTC的患者(中位年龄51.0岁,IQR 43.0-58.8;男42例、女16例),以脐水平CT测量的VFA≥100 cm²定义内脏肥胖,比较CTC衍生VFA、BMI和腰围的诊断效能,并用5折交叉验证和平均绝对误差(MAE)评估回归模型。

诊断标准与关键数值

  • 内脏肥胖定义为脐水平CT测量的VFA≥100 cm²;CTC衍生VFA诊断内脏肥胖的敏感度0.90、特异度0.93,BMI为0.73和0.75,腰围为0.90和0.79。

临床应用与阅片要点

  • 在CTC图像上可测量VFA用于识别内脏肥胖,无需额外辐射或成本;多切片模型较单切片模型预测准确性更高,纳入额外切片(如L2)使MAE从19.76降至16.54 cm²(P=0.013)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Visceral obesity is a significant health risk, and the visceral fat area (VFA) measured on CT is a reliable indicator. The current study investigated whether the CT colonography (CTC)-derived VFA can identify visceral obesity, accounting for imaging variations due to colonic insufflation.

METHODS: We retrospectively included patients who underwent both abdominal CT and CTC within 30 days. The waist circumference, VFA, and subcutaneous fat area (SFA) were measured at the umbilical and L1-L5 vertebral levels. Visceral obesity was defined as a VFA ≥ 100 cm² at the umbilical level on CT. The diagnostic performances of the CTC-derived VFA, BMI, and waist circumference were compared. In a secondary analysis, regression models were constructed to estimate the CT-derived VFA from the CTC measurements. Model performance was evaluated via 5-fold cross-validation and quantified with the mean absolute error (MAE).

RESULTS: Fifty-eight patients were included (median age 51.0 years, IQR 43.0-58.8; 42 males, 16 females). Compared with CT, CTC revealed a significantly greater waist circumference (89.9 vs. 87.5 cm, P < 0.001) and a lower VFA (96.0 vs. 110.3 cm², P = 0.005), whereas there was no significant difference in the SFA. The umbilical slice position remained unchanged in 49 patients (84.5%), and no patient's position shifted by two or more levels. The CTC-derived VFA demonstrated the highest diagnostic performance for visceral obesity, with a sensitivity and specificity of 0.90 and 0.93. BMI yielded 0.73 and 0.75, and waist circumference 0.90 and 0.79, respectively. Incorporating additional slices (e.g., L2) further reduced the MAE from 19.76 to 16.54 cm² (P = 0.013).

CONCLUSION: The CTC-derived VFA was shown to be a viable marker for identifying visceral obesity, thus potentially offering a secondary diagnostic resource without additional radiation exposure or costs. While single-slice models showed reasonable performance, multi-slice models demonstrated greater predictive accuracy.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。