深度学习重建的肝胆MRI:改善胆道勾画、病灶边缘锐利度及小病灶检出
这项回顾性研究纳入94例疑似肝脏病灶患者(145个病灶),在钆塞酸增强肝胆期比较深度学习重建VIBE(1.5 mm层厚)与常规VIBE(3.0 mm层厚)的胆道显示、病灶检出和伪影抑制,结果显示DL-VIBE三级胆管检出更高、病灶边缘更锐利、总体及微小病灶检出率更高,图像噪声和振铃伪影更低。
要点
- DL-VIBE较常规VIBE提高三级胆管检出(2.45 vs 0.93支,p<0.001)和连续性评分(2.97 vs 2.60,p<0.001)。
- DL-VIBE病灶边缘更锐利(ERD 0.93±0.50 mm vs 1.51±0.10 mm,P<0.001),总体检出率97.2% vs 91.0%(P=0.005)。
- DL-VIBE图像噪声更低(3.82 vs 2.25,p<0.001)并抑制振铃伪影(3.55 vs 2.30,p<0.001)。
核心结论
- DL-VIBE在钆塞酸增强肝胆期MRI中改善胆道微解剖勾画、病灶边缘分辨力及小病灶检出,提示在标准屏气时间内具有精准成像的临床实用性。
研究设计与样本
- 回顾性研究纳入94例疑似肝脏病灶患者(共145个病灶),检查时间为2025年3月至5月。
- 所有患者接受钆塞酸增强MRI肝胆期检查,使用DL-VIBE(1.5 mm层厚)与常规VIBE(3.0 mm层厚)两种序列。
- 采用盲法评估胆道解剖、病灶边缘及图像质量,包括定量指标(边缘上升距离ERD、对比噪声比CNR)和定性评分。
关键影像表现/征象
- DL-VIBE三级胆管检出为2.45 vs 常规VIBE 0.93支(DL-VIBE高163%,p<0.001),连续性评分2.97 vs 2.60(p<0.001)。
- DL-VIBE病灶边缘ERD为0.93±0.50 mm vs 常规VIBE 1.51±0.10 mm(P<0.001)。
- DL-VIBE图像噪声3.82 vs 常规VIBE 2.25(p<0.001),振铃伪影3.55 vs 2.30(p<0.001)。
- DL-VIBE胆管CNR为230.50 vs 常规VIBE 135.14(p<0.001)。
- DL-VIBE纹理自然度2.85 vs 常规VIBE 3.45(p=0.001)。
诊断标准与关键数值
- DL-VIBE总体病灶检出率97.2% vs 常规VIBE 91.0%(P=0.005)。
- DL-VIBE微小病灶检出率96.3% vs 常规VIBE 87.6%(P=0.004)。
临床应用与阅片要点
- DL-VIBE(1.5 mm层厚)可作为常规3 mm VIBE的改进替代方案,提升三级胆管显示和亚厘米病灶检出,有助于临床决策。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the comparative performance of a deep learning-reconstructed T1-weighted volumetric interpolated breath-hold examination (DL VIBE) on hepatobiliary phase MRI against the conventional T1 VIBE in biliary tree visualization, lesion detection, and artifact suppression.
MATERIALS AND METHODS: This retrospective study included 94 patients with suspected hepatic lesions (145 lesions, March-May 2025). All underwent gadoxetic acid-enhanced MRI at hepatobiliary phase using DL-VIBE (1.5 mm slice thickness) and conventional VIBE (3.0 mm). Blinded evaluations assessed biliary anatomy, lesion margins, and image quality through quantitative metrics (edge rise distance [ERD], CNR) and qualitative scoring.
RESULTS: DL-VIBE demonstrated superior biliary visualization with 163 % higher tertiary duct detection (2.45 vs. 0.93 branches, p < 0.001) and improved continuity scores (2.97 vs. 2.60, p < 0.001). Lesion margins showed significantly improved sharpness (ERD: 0.93 ± 0.50 mm vs. 1.51 ± 0.10 mm; P < 0.001), while lesion detection rates were significantly higher overall (97.2 % vs. 91.0 %; P = 0.005) and particularly for micro lesions (96.3 % vs. 87.6 %; P = 0.004). DL-VIBE reduced image noise (3.82 vs. 2.25, p < 0.001) and suppressed ringing artifacts (3.55 vs. 2.30, p < 0.001) while maintaining bile duct CNR gains (230.50 vs. 135.14, p < 0.001), though with marginally lower texture naturalness (2.85 vs. 3.45, p = 0.001).
CONCLUSION: DL-VIBE improves biliary microanatomy delineation, lesion margin resolution, and small lesion detection in gadoxetic acid-enhanced hepatobiliary MRI, suggesting clinical utility for precision imaging within standard breath-hold durations.
CLINICAL RELEVANCE STATEMENT: DL-reconstructed 1.5-mm HBP VIBE serves as an improved alternative to conventional 3-mm VIBE, offering enhanced tertiary bile duct visualization and subcentimeter lesion detection for better clinical decision-making.
引用
- Dai H, Chen J, Liu K, et al. Deep learning-reconstructed hepatobiliary MRI: Enhancing biliary delineation, lesion margin sharpness, and small lesion detection. Eur J Radiol. 2025. PMID: 41314015. doi:10.1016/j.ejrad.2025.112574
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。