文献速递腹部技术与安全USMR

用于量化肝脏脂肪变性的多参数超声方法的开发与评估

Development and Evaluation of a Multiparametric Ultrasound Approach for Quantifying Hepatic Steatosis.
PubMed 文献 · Ultrasound Med Biol · 2025-11-11

这项前瞻性双中心研究纳入133例患者,评估衰减系数、背向散射系数和Nakagami分布斑点统计三种超声标志物经肋间与肋下双入路联合构建的超声脂肪分数(UFF)与MRI测得的PDFF的相关性及诊断性能。结果显示UFF与PDFF强相关(r2=0.79),鉴别S0与≥S1的AUROC为0.94,鉴别≤S1与≥S2的AUROC为0.98。

要点

  • 联合肋间与肋下双入路测量的UFF与MRI-PDFF强相关(r2=0.79)。
  • UFF鉴别S0与≥S1的AUROC为0.94,鉴别≤S1与≥S2的AUROC为0.98。
  • 单独三种超声标志物均与PDFF相关,衰减系数r2为0.72(肋间)和0.65(肋下)。

核心结论

  • UFF与PDFF在脂肪变性定量方面强相关,联合肋间与肋下测量可改善这一相关性。

研究设计与样本

  • 前瞻性双中心研究,纳入133例患者,以MRI测得的PDFF为金标准,比较肋间与肋下入路三种超声标志物并与PDFF进行二阶多项式拟合。

诊断标准与关键数值

  • 衰减系数与PDFF的r2=0.72(肋间)和0.65(肋下),背向散射系数r2=0.68(肋间)和0.69(肋下),Nakagami m参数r2=0.51(肋间)和0.52(肋下),UFF与PDFF的r2=0.79;UFF鉴别S0与≥S1的AUROC为0.94,鉴别≤S1与≥S2的AUROC为0.98。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Accessible and noninvasive methods are crucial for the detection and monitoring of steatosis. This study assessed the performance of ultrasound via three ultrasound markers-the attenuation coefficient, the backscattering coefficient and speckle statistics-modeled by a Nakagami distribution, using a dual intercostal and subcostal approach. Combining these three ultrasound markers obtained from the inter- and subcostal acquisitions generated the ultrasound-based fat fraction (UFF). The PDFF measured with MRI was used as the gold standard.

MATERIALS AND METHODS: One hundred thirty-three patients were included in this prospective, bicentric study. For both the intercostal and subcostal approaches, the three ultrasound markers were compared with the PDFF and their coefficients of determination were estimated by means of a second-order polynomial fit. The correlation between the UFF and PDFF was assessed using the Pearson correlation coefficient. ROC curves were used to study the performance of UFF.

RESULTS: Independently, all three ultrasound markers were well correlated with the PDFF: attenuation coefficient r2 = 0.72 (intercostal) and r2 = 0.65 (subcostal), backscattering coefficient r2 = 0.68 (intercostal) and r2 = 0.69 (subcostal), and Nakagami m parameter r2 = 0.51 (intercostal) and r2 = 0.52 (subcostal). The UFF score was strongly correlated with the PDFF (r2 = 0.79). The areas under the ROC curves (AUROCs) were 0.94 to distinguish between grade S0 and grades ≥ S1 and 0.98 to distinguish between ≤ S1 and ≥ S2.

CONCLUSION: UFF is strongly correlated with PDFF for steatosis quantification. Combining both intercostal and subcostal measurements improves this correlation with PDFF.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Carmier L, Aube C, Lecharpentier A, et al. Development and Evaluation of a Multiparametric Ultrasound Approach for Quantifying Hepatic Steatosis. Ultrasound Med Biol. 2025. PMID: 41224631. doi:10.1016/j.ultrasmedbio.2025.10.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。