基于体重和管电压完全个体化对比剂注射方案在低剂量高螺距冠状动脉CT血管成像中的应用

Fully personalized contrast injection optimized for weight and tube voltage in low-dose high-pitch coronary CT angiography.
PubMed 文献 · Eur J Radiol · 2025-10-30

单中心研究纳入112例行临床指征冠状动脉CT血管成像的患者,56例采用基于体重和自动管电压选择的完全个体化对比剂注射方案(MINDS-CAD,高螺距扫描),56例匹配对照采用机构标准方案(回顾性螺旋扫描)。MINDS-CAD组冠状动脉衰减更高(391.1±88.1 HU vs 305.6±103.1 HU,p<0.001)、主观图像质量更优(4分 vs 3分,p<0.001),且辐射剂量更低(90±50 mG·cm vs 576±386 mG·cm,p<0.001)。

要点

  • MINDS-CAD方案根据体重和自动管电压选择调整对比剂注射流率(1.7-9.7 mL/s)和对比剂用量(23-97 mL),共生成56对用量与流率组合。
  • MINDS-CAD组冠状动脉衰减391.1±88.1 HU,标准方案组305.6±103.1 HU,p<0.001。
  • MINDS-CAD组主观图像质量4分(IQR 3-4),标准方案组3分(IQR 3-3),p<0.001;图像质量差(Likert 1分)比例3.5% vs 8.8%。

核心结论

  • 完全个体化、基于体重和管电压调整的对比剂方案实现了更一致的冠状动脉衰减和更优的图像质量,在肥胖为主的人群中展现了该方案的稳健性。

研究设计与样本

  • IRB批准的单中心研究,纳入112例行临床指征冠状动脉CT血管成像的患者,使用第三代双源CT;56例采用MINDS-CAD方案(根据体重和自动管电压选择调整对比剂流率和用量,高螺距扫描),56例匹配对照采用机构标准方案(回顾性螺旋扫描)。

关键影像表现/征象

  • MINDS-CAD组冠状动脉近段和远段衰减均值为391.1±88.1 HU,标准方案组为305.6±103.1 HU,p<0.001。
  • MINDS-CAD组主观图像质量评分为4分(IQR 3-4),标准方案组为3分(IQR 3-3),p<0.001。
  • MINDS-CAD组图像质量差(Likert 1分)比例为3.5%,标准方案组为8.8%。
  • 标准方案组中BMI和管电压可预测冠状动脉衰减(β=-7.998和-2.864,p<0.001),MINDS-CAD组中二者均不能预测(p=0.411)。

诊断标准与关键数值

  • 主观图像质量采用四分制评分,4分为极好。
  • MINDS-CAD方案对比剂注射流率范围1.7-9.7 mL/s,对比剂用量范围23-97 mL。
  • 机构标准方案对比剂用量范围50-80 mL,注射流率范围3.2-5.0 mL/s。

临床应用与阅片要点

  • MINDS-CAD方案根据体重和自动管电压选择个体化调整对比剂流率与用量,在高螺距扫描下可提高冠状动脉衰减的均一性。
  • 该方案在肥胖患者(BMI≥30 kg/m2,占60%以上)中仍能获得优于标准方案的图像质量和更低的辐射剂量。
  • 标准方案中BMI和管电压影响冠状动脉衰减,而MINDS-CAD方案中这种影响不再显著,提示个体化调整可减少体型和扫描参数对强化的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: To evaluate the performance of a fully individualized, weight- and tube voltage-tailored contrast media injection protocol (MINDS-CAD) for high-pitch coronary CT angiography (CCTA).

METHODS: This IRB-approved, single-center study included 112 patients undergoing clinically indicated CCTA using third-generation dual-source CT. Fifty-six patients were scanned with the MINDS-CAD protocol, which adapts contrast delivery rate (DR, range: 1.7-9.7 mL/s) and contrast volume (CV, range: 23-97 mL) based on body weight and automatic tube voltage selection, creating 56 pairs of CV and DR and uses high-pitch scanning. Fifty-six matched controls underwent CCTA with an institutional standard protocol (retrospective spiral scan, CV, range: 50-80 mL; DR, range: 3.2-5.0 mL/s). Objective image quality was assessed via coronary artery attenuation (HU) in proximal and distal segments. Subjective image quality was graded on a four-point scale (4: excellent), and multiple linear regression was used to identify predictors of coronary attenuation. Dose-length-product (DLP) was compared between cohorts.

RESULTS: Groups were matched for age, BMI, and heart rate (all p > 0.05); over 60 % were obese (BMI ≥ 30 kg/m2). Coronary attenuation was higher with MINDS-CAD (391.1 ± 88.1 HU vs. 305.6 ± 103.1 HU, p < 0.001). Subjective quality was superior (4 [IQR: 3-4] vs. 3 [IQR: 3-3], p < 0.001), with fewer poor-quality scans (Likert 1, 3.5 % vs. 8.8 %) in the MINDS-CAD cohort. In the standard group, BMI and tube voltage predicted attenuation (β = -7.998 and -2.864; p < 0.001), whereas in the MINDS-CAD group, neither was predictive (p = 0.411). Most importantly, MINDS-CAD achieved superior image quality in a matched cohort while considerably lowering radiation dose (90 ± 50 mG•cm vs 576 ± 386 mG•cm, p < 0.001).

CONCLUSION: A fully individualized, weight- and tube voltage-tailored contrast protocol achieved more consistent coronary attenuation and superior image quality. These results, demonstrated in a predominantly obese cohort, highlight the robustness of the protocol and provide a framework for reliable low-dose, high-pitch CCTA across challenging patient populations.