预测经导管主动脉瓣置换术后起搏器依赖:心电图、临床及CT影像参数分析
本研究纳入2012年5月至2019年12月在本机构接受经股动脉SAPIEN 3瓣膜TAVR的连续患者,最终分析301例术后植入起搏器的患者,其中168例(55.8%)起搏器依赖。多因素分析显示瓣膜oversizing(OR 1.09,p<0.001)、左冠瓣下方钙化(OR 1.02,p<0.001)和术前右束支传导阻滞(OR 2.20,p=0.025)是起搏器依赖的显著预测因素;仅含这些变量的简化模型AUC为0.752,优于全模型AUC 0.660(p=0.037)。
要点
- 术前右束支传导阻滞是TAVR术后起搏器依赖的最强预测因素(OR 2.20)。
- 瓣膜oversizing和左冠瓣下方钙化也是起搏器依赖的独立预测因素。
- 仅用这三个变量的简化模型预测起搏器依赖的AUC为0.752,优于全模型。
核心结论
- 术前右束支传导阻滞是TAVR术后起搏器依赖的最强预测因素,其次为瓣膜oversizing和左冠瓣下方钙化;简化预测模型具有中等预测准确度。
研究设计与样本
- 回顾性分析本机构2012年5月至2019年12月连续接受经股动脉SAPIEN 3瓣膜TAVR的患者,初始2105例中350例(16.6%)术后植入起搏器,排除后纳入301例(起搏器依赖168例,非依赖133例),主要终点为术后首次门诊随访时心室起搏百分比≥1%。
诊断标准与关键数值
- 起搏器依赖定义为TAVR术后起搏器植入后首次门诊随访时心室起搏百分比≥1%;多因素分析中瓣膜oversizing OR 1.09(p<0.001)、左冠瓣下方钙化OR 1.02(p<0.001)、术前右束支传导阻滞OR 2.20(p=0.025);简化模型预测起搏器依赖的AUC为0.752,全模型AUC为0.660(p=0.037)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Conduction disturbances necessitating permanent pacemaker (PPM) implantation following transcatheter aortic valve replacement (TAVR) have been observed. However, limited data exist on ECG, clinical, and CT-imaging factors predicting PPM dependency after TAVR. This study aimed to identify predictors of pacemaker dependency in selected patients who required PPM implantation after TAVR with SAPIEN 3 prostheses.
MATERIALS AND METHODS: This study included consecutive patients who underwent transfemoral TAVR with SAPIEN 3 prostheses at our institution between May 2012 and December 2019. Exclusion criteria were incomplete or non-diagnostic data, valve-in-valve procedures, TAVR in mitral position, previous surgical repair, and pre-implanted PPM. The primary endpoint was PPM dependency, defined as ventricular pacing percentage ≥ 1 % at the first outpatient follow-up after PPM implantation post-TAVR. Regression analysis was performed to compare a limited prediction model for PPM dependency using only selected variables to a full model with all available variables.
RESULTS: Out of 2105 patients who received TAVR, 350 (16.6 %) required pacemaker implantation post-TAVR. After exclusions, 301 patients remained, with 168 (55.8 %) PPM-dependent and 133 (44.2 %) non-dependent patients. Multivariate analysis identified prosthesis oversizing (OR: 1.09, p < 0.001), calcification below the left coronary cusp (LCC) (OR: 1.02, p < 0.001), and right bundle branch block (RBBB) prior to TAVR (OR: 2.20, p = 0.025) as significant predictors. A limited regression model predicted PPM dependency with an AUC of 0.752, significantly outperforming the full model (AUC: 0.660, p = 0.037).
CONCLUSION: RBBB prior to TAVR was the strongest predictor of PPM dependency post-TAVR, followed by prosthesis oversizing and calcification below the LCC. A limited prediction model with these variables demonstrated moderate predictive accuracy.
引用
- Klambauer K, Rizas KD, Fabritius MP, et al. Predicting pacemaker dependency after transcatheter aortic valve replacement: Analysis of ECG, clinical, and CT-imaging parameters. Eur J Radiol. 2025. PMID: 41273923. doi:10.1016/j.ejrad.2025.112534
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。