文献速递心血管技术与安全PET

SPECT对感染性心内膜炎的诊断价值:系统评价与荟萃分析

Diagnostic value of SPECT for endocarditis: a systematic review and meta-analysis.
PubMed 文献 · Clin Radiol · 2025-10-08

该系统评价与荟萃分析纳入25项研究(其中21项进入荟萃分析),评估SPECT对感染性心内膜炎的诊断效能;汇总敏感度75.8%、特异度87.4%、AUROC 0.816,99mTc-HMPAO-WBC SPECT诊断心脏装置相关感染性心内膜炎的敏感度82.9%、特异度91.4%。

要点

  • SPECT诊断感染性心内膜炎汇总敏感度75.8%、特异度87.4%、AUROC 0.816。
  • 99mTc-HMPAO-WBC SPECT诊断心脏装置相关感染性心内膜炎敏感度82.9%、特异度91.4%。
  • 作者认为SPECT在传统影像无法确诊时可能尤其有价值。

核心结论

  • 荟萃分析显示闪烁显像检测感染性心内膜炎具有较高诊断准确度,可能对诊断心脏装置相关感染性心内膜炎尤其有价值,尤其在传统影像学检查无法确诊时;仍需多中心研究确立SPECT在感染性心内膜炎整体诊断框架中的作用。

研究设计与样本

  • 系统评价与荟萃分析,按PRISMA和QUADAS-2标准执行,检索Medline、Embase和Cochrane数据库,共识别1099条记录(截至2024年发表),25项研究纳入系统评价、21项纳入荟萃分析。

诊断标准与关键数值

  • SPECT检测感染性心内膜炎汇总敏感度75.8%、特异度87.4%,总体准确度AUROC=0.816。
  • 99mTc-HMPAO-WBC SPECT诊断心脏装置相关感染性心内膜炎敏感度82.9%、特异度91.4%。

临床应用与阅片要点

  • 作者认为闪烁显像在传统影像学检查无法确诊的病例中可能尤其有价值,尤其用于诊断心脏装置相关感染性心内膜炎。
  • 作者指出仍需多中心研究确立SPECT在感染性心内膜炎整体诊断框架中的作用。

局限性

  • 作者指出仍需多中心研究以确立SPECT在感染性心内膜炎更广泛诊断框架中的作用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: Early identification of infective endocarditis (IE) and proper treatment can limit mortality and complications. The ability of scintigraphy in locating acute inflammatory lesions can be useful in improving diagnostic efficiency. This systematic review and meta-analysis assessed the diagnostic performance of SPECT in patients with IE.

MATERIALS AND METHODS: The analysis was performed in accordance with PRISMA and QUADAS-2 criteria and included articles from Medline, Embase, and Cochrane databases. A total of 1099 records were identified, published until 2024. Of these, 25 studies were included in the systematic review, and 21 studies were included in the meta-analysis.

RESULTS: Summary estimates for SPECT show high diagnostic accuracy for detecting IE, with a sensitivity of 75.8% and specificity of 87.4%, as well as excellent overall accuracy (AUROC = 0.816). A higher sensitivity and specificity, 82.9% and 91.4% respectively, were observed for cardiac device related endocarditis (CDRE) diagnosis using 99mTc-HMPAO-WBC SPECT.

CONCLUSION: This meta-analysis demonstrates that scintigraphy exhibits high diagnostic accuracy in detecting IE, and may be especially valuable in diagnosing CDRE, especially in cases where traditional imaging modalities are inconclusive. Nonetheless, multicenter studies are needed to establish the role of SPECT within the broader diagnostic framework for IE.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Aslam R, Caba J, Jamsran J, et al. Diagnostic value of SPECT for endocarditis: a systematic review and meta-analysis. Clin Radiol. 2025. PMID: 41187698. doi:10.1016/j.crad.2025.107120

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。