真实临床实践中的快速晚期钆增强心脏MRI:一项前瞻性临床试验
这项前瞻性研究连续纳入2022年3月至2023年4月接受增强心脏MRI三种晚期钆增强序列检查的参与者,以PSIR turboFLASH为参考标准,比较PSIR单次激发TrueFISP与运动校正TrueFISP PSIR在图像质量、晚期钆增强定位和定量方面的表现。结果显示两种快速序列图像质量评分和对比噪声比均高于turboFLASH(P < .001),在缺血性心脏病参与者中三种序列的晚期钆增强定量无差异证据,组内相关系数为0.99。
要点
- 两种快速晚期钆增强序列在单次屏气或自由呼吸状态下即可获得良好图像质量,图像质量评分和对比噪声比均高于turboFLASH(P < .001)。
- 112例晚期钆增强阳性和67例阴性参与者的结果在TrueFISP与moco PSIR上均与turboFLASH一致。
- 缺血性心脏病参与者中三种序列的晚期钆增强质量、微血管阻塞定量无差异证据,组内相关系数0.99。
核心结论
- 两种快速序列在单次屏气或自由呼吸状态下获得良好图像质量,并且在缺血性心脏病参与者中实现了准确的晚期钆增强定位和定量。
研究设计与样本
- 前瞻性研究,连续纳入2022年3月至2023年4月接受增强心脏MRI三种晚期钆增强序列检查的参与者共187例(平均年龄56.7岁±15.1[SD],125例男性),以PSIR turboFLASH为参考标准,与TrueFISP PSIR及moco PSIR比较。
关键影像表现/征象
- 晚期钆增强阳性112例(60%)、阴性67例(36%),TrueFISP与moco PSIR两种快速序列结果均与turboFLASH一致。
- moco PSIR与TrueFISP的整体图像质量评分和对比噪声比均高于turboFLASH(P < .001)。
- 缺血性心脏病参与者(n = 94)中,三种序列在晚期钆增强阳性层数或节段计数、晚期钆增强质量及微血管阻塞定量方面未发现差异证据。
- Bland-Altman与组内相关系数分析显示序列间一致性良好(组内相关系数0.99)。
诊断标准与关键数值
- 以PSIR turboFLASH序列为参考标准,比较TrueFISP PSIR与moco PSIR序列。
- 主要结局为整体图像质量评分与对比噪声比;次要结局为晚期钆增强及微血管阻塞的定性与定量评估。
- 缺血性心脏病参与者(n = 94)中三种序列的晚期钆增强定量比较未发现差异证据,组内相关系数为0.99。
临床应用与阅片要点
- 两种快速序列可在单次屏气或自由呼吸状态下完成采集,图像质量评分和对比噪声比高于turboFLASH(P < .001)。
- 在缺血性心脏病参与者中,快速序列的晚期钆增强定位与定量结果与turboFLASH一致,组内相关系数0.99。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To compare two rapid late gadolinium enhancement (LGE) cardiac MRI sequences-phase-sensitive inversion recovery (PSIR) single-shot true fast imaging with steady-state precession (TrueFISP) and motion-corrected TrueFISP PSIR (moco PSIR)-with the PSIR turbo fast low-angle shot (turboFLASH) sequence regarding image quality, localization, and quantification of LGE. Materials and Methods This prospective study included consecutive participants who underwent contrast-enhanced cardiac MRI with three LGE sequences between March 2022 and April 2023. TurboFLASH was the reference standard and was compared with the TrueFISP PSIR and moco PSIR sequences. Primary outcomes were overall image quality scores and contrast-to-noise ratios. Secondary outcomes included qualitative and quantitative assessments of LGE and microvascular obstruction. Statistical analyses included t tests, Wilcoxon signed rank tests, Bland-Altman analysis, and intraclass correlation coefficient. Results A total of 187 participants (mean age, 56.7 years ± 15.1 [SD]; 125 male participants) successfully underwent imaging using all three LGE sequences. All 112 LGE-positive (60%) and 67 LGE-negative (36%) participants undergoing turboFLASH sequencing showed identical results using both TrueFISP and moco PSIR. Overall image quality scores and contrast-to-noise ratios were higher for moco PSIR and TrueFISP than for turboFLASH (P < .001). In participants with ischemic heart disease (n = 94), we found no evidence of difference among the three sequences in LGE-positive layers or segment counts, LGE mass, or microvascular obstruction quantification. Bland-Altman and intraclass correlation coefficient analyses showed a strong agreement across sequences (intraclass correlation coefficient, 0.99). Conclusion Good image quality was achieved with the two rapid sequences in a single breath hold or free-breathing state, in addition to accurate LGE localization and quantification in participants with ischemic heart disease. Keywords: MR-Contrast Agent, Cardiac Supplemental material is available for this article. © The Author(s) 2025. Published by the Radiological Society of North America under a CC BY 4.0 license.
引用
- Kong H, Zhou J, Li J, et al. Rapid Late Gadolinium Enhancement Cardiac MRI in Real-World Clinical Practice: A Prospective Clinical Trial. Radiol Cardiothorac Imaging. 2025. PMID: 41231127. doi:10.1148/ryct.240477
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。