孤立性三尖瓣反流患者经导管缘对缘修复术后的超声心动图结局:Tri.Fr试验
Tri.Fr试验纳入300例重度继发性三尖瓣反流患者,随机分为T-TEER+GDMT组(152例)与GDMT组(148例),由核心超声实验室评估基线至1年的超声参数变化。T-TEER+GDMT组右心室功能多数参数显著下降,而GDMT组右心室指标无显著变化;临床复合评分随三尖瓣反流减少程度逐级改善,T-TEER对复合评分的正面效应仅见于右心室-肺动脉耦联正常者。
要点
- T-TEER+GDMT组1年内多数右心室功能参数显著下降,GDMT组右心室指标无显著变化。
- 临床复合评分随三尖瓣反流减少程度逐级改善,T-TEER的正面效应仅见于右心室-肺动脉耦联正常者。
- 1年时临床复合评分改善者右心房容积指数低于未改善或恶化者(中位112 vs 141 mL/m2,P=0.004)。
核心结论
- T-TEER虽可降低三尖瓣反流严重程度,但对常规右心室功能参数及右心室-肺动脉耦联的影响仍有限;与实现三尖瓣反流严重程度最佳减少相比,右心室功能恢复对1年临床结局的影响较小。
研究设计与样本
- Tri.Fr试验(NCT04646811)为随机分组研究,共纳入300例重度继发性三尖瓣疾病患者,T-TEER+GDMT组152例、GDMT组148例,由中心化超声心动图核心实验室评估基线至1年的超声参数变化。
关键影像表现/征象
- T-TEER+GDMT组患者多数右心室功能参数显著下降,GDMT组1年时右心室指标无显著变化。
- 1年时临床复合评分改善者右心房容积指数中位112 mL/m2(Q1-Q3:78.0-146 mL/m2),低于评分未变或恶化者的中位141 mL/m2(Q1-Q3:107-173 mL/m2),P=0.004。
诊断标准与关键数值
- 右心室-肺动脉耦联正常定义为三尖瓣环收缩期位移与收缩期肺动脉压比值≥0.40,T-TEER对临床复合评分的正面效应仅见于该组。
临床应用与阅片要点
- 评估T-TEER后右心功能变化时,需注意常规右心室功能参数可能下降,而右心室-肺动脉耦联(TAPSE/sPAP≥0.40)正常者才显示T-TEER对临床复合评分的正面效应。
- 报告三尖瓣反流减少程度时应与临床复合评分变化结合解读,反流减少越显著临床复合评分改善越明显。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The relationships among tricuspid regurgitation (TR) reduction after tricuspid transcatheter edge-to-edge repair (T-TEER), changes in right-sided heart function, and outcomes are poorly explored.
OBJECTIVES: This study aims to explore the relationship between functional remodeling and subsequent outcomes and the associations among T-TEER, residual TR, and outcomes.
METHODS: Changes in echocardiographic parameters from baseline to 1 year, overall and according to TR reduction were evaluated by a centralized echocardiographic core laboratory in patients included in the Tri.Fr (Evaluation of Tricuspid Valve Percutaneous Repair System in the Treatment of Severe Secondary Tricuspid Disorders) trial.
RESULTS: A total of 300 patients (aged 78 ± 5 years; 53.7% women) were enrolled; 152 patients were allocated to the T-TEER + guideline-directed medical therapy (GDMT) group, and 148 were allocated to the GDMT group. Patients in the T-TEER + GDMT group demonstrated a significant decrease in most of parameters of right ventricular (RV) function, whereas patients in the GDMT group exhibited no significant changes in RV metrics at 1 year. The clinical composite score improved progressively with each successive grade of TR reduction. The positive effect of T-TEER on the composite clinical score was observed irrespective of baseline right atrial volume but only in patients with normal RV-pulmonary artery coupling (defined by a tricuspid annular plane systolic excursion-to-systolic pulmonary artery pressure ratio ≥0.40). At 1 year, patients with an improved clinical composite score had a lower right atrial volume index compared with patients whose clinical score remained unchanged or worsened (median 112 mL/m2 [Q1-Q3: 78.0-146 mL/m2] vs median 141 mL/m2 [Q1-Q3: 107-173 mL/m2]; P = 0.004).
CONCLUSIONS: Although T-TEER can decrease TR severity, its impact on conventional RV function parameters and RV-pulmonary artery coupling remains limited. RV functional recovery has a smaller influence on clinical outcomes at 1 year compared with achieving optimal reduction in TR severity. (Evaluation of Tricuspid Valve Percutaneous Repair System in the Treatment of Severe Secondary Tricuspid Disorders [Tri.Fr]; NCT04646811).
引用
- Coisne A, L'Official G, Dreyfus J, et al. Echocardiographic Outcomes After Transcatheter Edge-to-Edge Repair in Patients With Isolated Tricuspid Regurgitation: The Tri.Fr Trial. JACC Cardiovasc Imaging. 2025. PMID: 41258847. doi:10.1016/j.jcmg.2025.09.010