文献速递外周血管腹部MRCT

扩散加权MRI检测腹主动脉瘤腔内修复术后内漏的可行性

Feasibility of Diffusion-weighted MRI for Detecting Abdominal Aortic Endoleaks after Endovascular Aneurysm Repair.
PubMed 文献 · Radiology · 2025-01-01

单中心前瞻性研究纳入34例腔内修复术后患者,比较DWI联合ADC图及其他非增强MRA序列与CTA检测内漏的效能,敏感度95%、特异度93%、准确率94%,与CTA无显著差异;加入ADC-FIESTA融合图后观察者间一致性从κ=0.60升至0.82。

要点

  • 内漏与支架内血流的ADC比值(0.97±0.12)显著高于血栓与支架内血流的比值(0.52±0.12),P<.001。
  • DWI+ADC图联合其他非增强MRA序列检测内漏:敏感度95%、特异度93%、准确率94%。
  • 流入反转恢复序列检出2例Ia型内漏,未检出Ib型和II型内漏。

核心结论

  • DWI联合ADC图、其他非增强MRA序列及ADC-FIESTA融合图可准确、无创地检测腹主动脉内漏。

研究设计与样本

  • 单中心前瞻性研究,2022年5月至2024年2月纳入34例腔内修复术后患者,3个月内行CTA及非增强MRA(含DWI、ADC图、FIESTA、流入反转恢复、二维相位对比成像),以CTA为参考标准,两名盲法阅片者独立评估。

关键影像表现/征象

  • 内漏表现为DWI高信号且ADC图相应区域扩散受限,ADC值接近支架内血流。
  • 内漏与支架内血流的平均ADC比值为0.97±0.12,血栓与支架内血流的平均ADC比值为0.52±0.12。
  • 流入反转恢复序列检出2例Ia型内漏,未检出Ib型和II型内漏。

诊断标准与关键数值

  • DWI+ADC图联合其他非增强MRA序列对比CTA:敏感度95%(19/20;95%CI:75,100),特异度93%(13/14;95%CI:66,100),总准确率94%(32/34;95%CI:80,99),P=.48。
  • 内漏与支架内血流的平均ADC比值为0.97±0.12,显著高于血栓与支架内血流的平均ADC比值0.52±0.12(P<.001)。
  • 观察者间一致性κ=0.60,加入ADC-FIESTA融合图后为κ=0.82(P=.09)。

临床应用与阅片要点

  • 可联合DWI与ADC图及其他非增强MRA序列用于检测内漏,ADC-FIESTA融合图有助于提高观察者间一致性。
  • 流入反转恢复序列对Ia型内漏可检出,但未检出Ib型和II型内漏。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Unlike gadolinium-enhanced MR angiography, which relies on contrast enhancement, diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) mapping can be used to detect endoleaks based on differences in water molecule diffusion. Purpose To evaluate the diagnostic accuracy of DWI and ADC mapping combined with other noncontrast MR angiographic (NC-MRA) sequences for detecting endoleaks in participants after endovascular aneurysm repair. Materials and Methods In this single-center prospective study conducted between May 2022 and February 2024, 34 participants underwent CT angiography (CTA) and NC-MRA (including DWI, ADC mapping, fast imaging employing steady-state acquisition [FIESTA], inflow inversion recovery, and two-dimensional phase-contrast imaging) within 3 months. Two blinded reviewers assessed endoleaks independently in two sessions; the second session included ADC-FIESTA fusion images. Diagnostic accuracy of DWI with ADC mapping plus other NC-MRA sequences versus CTA was calculated, and interobserver agreement was assessed using Cohen κ. The ratios of the ADC value of the endoleak and of the adjacent thrombus to the ADC value within the aortic stent were calculated. Results DWI with ADC mapping plus other NC-MRA sequences achieved a sensitivity of 95% (19 of 20; 95% CI: 75, 100), a specificity of 93% (13 of 14; 95% CI: 66, 100), and an overall accuracy of 94% (32 of 34; 95% CI: 80, 99), compared with CTA (P = .48). The mean ADC ratio of endoleak to aortic stent flow was 0.97 ± 0.12 (SD), significantly higher than the mean ADC ratio of thrombus to aortic stent flow (0.52 ± 0.12; P < .001). With inflow inversion recovery, two type Ia endoleaks were detected, but type Ib and type II endoleaks were not detected. Interobserver agreement improved from κ = 0.60 to κ = 0.82 with the inclusion of ADC-FIESTA fusion images (P = .09). Conclusion DWI and ADC mapping combined with other NC-MRA sequences and ADC-FIESTA fusion images offers an accurate and noninvasive method for detecting abdominal aortic endoleaks. © RSNA, 2025 Supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Hsu MY, Chen CM, Wu MC, et al. Feasibility of Diffusion-weighted MRI for Detecting Abdominal Aortic Endoleaks after Endovascular Aneurysm Repair. Radiology. 2025. PMID: 41217285. doi:10.1148/radiol.243466

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。