文献速递心血管外周血管US

评估冠状动脉旁路移植术患者校正左心室射血时间与校正颈动脉血流时间之间的临床一致性

Evaluating the Clinical Agreement Between Corrected Left Ventricular Ejection Time and Corrected Carotid Flow Time in Coronary Artery Bypass Graft Surgery Patients.
PubMed 文献 · Ultrasound Med Biol · 2025-11-13

前瞻性观察性研究纳入17例成人冠状动脉旁路移植术患者,在切皮前和关胸后分别用经食管超声测校正左心室射血时间、颈动脉超声测校正颈动脉血流时间,均按Bazett和Wodey公式手动及自动算法计算。手动校正颈动脉血流时间与校正左心室射血时间强相关(Bazett r=0.88,Wodey r=0.96),一致性可接受(Bazett 91%,Wodey 93%),自动算法一致性差;作者认为手动值可能作为校正左心室射血时间的替代指标。

要点

  • 手动计算的校正颈动脉血流时间与校正左心室射血时间强相关,Bazett公式r=0.88、Wodey公式r=0.96。
  • 手动值一致性Bazett公式91%、Wodey公式93%,偏倚<11 ms,Bazett界限-35至57 ms、Wodey界限-15至35 ms。
  • 自动算法一致性差,作者认为手动校正颈动脉血流时间可能作为校正左心室射血时间的替代指标。

核心结论

  • 自动量化临床一致性差,而手动计算的校正颈动脉血流时间与校正左心室射血时间显示强临床一致性,提示手动校正颈动脉血流时间值可能作为校正左心室射血时间的可行替代指标,未来需优化自动算法以用于临床应用。

研究设计与样本

  • 前瞻性观察性研究,纳入17例接受冠状动脉旁路移植术的成人患者;校正左心室射血时间用经食管超声心动图测量,校正颈动脉血流时间用颈动脉超声评估,均在切皮前和关胸后测量;所有值均用Bazett和Wodey公式手动及通过自动算法计算;进行相关性、Bland-Altman和一致性分析。

诊断标准与关键数值

  • 手动计算的校正颈动脉血流时间与校正左心室射血时间:Bazett公式r=0.88(95%CI 0.77-0.94,p<0.001),Wodey公式r=0.96(95%CI 0.91-0.98,p<0.001);偏倚<11 ms;一致性界限Bazett公式-35至57 ms、Wodey公式-15至35 ms;一致性Bazett公式91%、Wodey公式93%。

临床应用与阅片要点

  • 作者认为手动计算的校正颈动脉血流时间值可能作为校正左心室射血时间的可行替代指标;自动量化临床一致性差,未来需优化自动算法以用于临床应用。

局限性

  • 原文结论指出需要进一步努力优化自动算法以供未来临床应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Perioperative hemodynamic monitoring plays a crucial role in reducing complications during coronary artery bypass graft (CABG) surgery. Corrected left ventricular ejection time (cLVET) is used to assess cardiac contractility but requires specialized echocardiography expertise. Corrected carotid flow time (ccFT), a non-invasive carotid Doppler-based method, could serve as an alternative, but its agreement with cLVET in CABG patients remains uncertain. This study evaluates the clinical agreement between these two measures in a real-world clinical setting.

METHODS: In this prospective observational study, 17 adult patients undergoing CABG surgery were included. cLVET was measured using transesophageal echocardiography, while ccFT was assessed via carotid ultrasound, both before incision and after thoracic closure. All values were calculated using Bazett's and Wodey's formulas, manually and through an automated algorithm. Correlation, Bland-Altman, and concordance analyses were conducted to evaluate the relationships between the measures.

RESULTS: Manual quantification showed better clinical agreement than automated analysis. Manually-derived ccFT values showed a strong correlation with cLVET using Bazett's formula (r = 0.88, 95% CI [0.77-0.94], p < 0.001) and Wodey's formula (r = 0.96, 95% CI [0.91-0.98], p < 0.001), with an acceptable bias (<11 ms) and narrow limits of agreement (Bazett: -35 to 57 ms; Wodey: -15 to 35 ms). Concordance was acceptable for Bazett (91%) and good for Wodey (93%).

CONCLUSION: While automated quantification yielded poor clinical agreement, manually computed ccFT demonstrated a strong clinical agreement with cLVET. This suggests that manually derived ccFT values could serve as a viable surrogate for cLVET. Further effort is needed to optimize automated algorithms for future clinical applications.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. de Boer EC, de Raat FM, Dinis Fernandes C, et al. Evaluating the Clinical Agreement Between Corrected Left Ventricular Ejection Time and Corrected Carotid Flow Time in Coronary Artery Bypass Graft Surgery Patients. Ultrasound Med Biol. 2025. PMID: 41238457. doi:10.1016/j.ultrasmedbio.2025.10.007