文献速递胸部MR

比较均值锚定广义线性分箱与现有方法量化氙-129通气缺陷百分比

Comparing Mean-anchored Generalized Linear Binning with Established Methods to Quantify Xenon-129 Ventilation Defect Percentage.
PubMed 文献 · Acad Radiol · 2025-11-14

研究纳入38例囊性纤维化患者和25例年龄匹配健康对照,采用二维螺旋序列采集超极化氙-129 MRI,提出均值锚定广义线性分箱(MeanGLB)计算通气缺陷百分比(VDP),并与读者分割VDP及五种自动方法比较。MeanGLB与读者分割VDP强相关(r=0.97,P<0.001),在N4和FA校正图像上Youden指数最高(约0.75),且不依赖偏倚校正算法。

要点

  • MeanGLB在N4和FA校正图像上均与读者分割VDP强相关(r=0.97,P<0.001)。
  • MeanGLB的Youden指数约0.75,在N4和FA校正图像上均为最高,敏感度与特异度平衡最佳。
  • MeanGLB在囊性纤维化患者中高估缺陷(Bland-Altman偏倚N4校正-3.1%、FA校正-1.9%)。

核心结论

  • MeanGLB能稳健量化氙-129通气MRI的VDP,不依赖偏倚校正算法,其捕捉细微损伤的能力提示可用于肺部成像。

研究设计与样本

  • 研究论文;38例囊性纤维化患者和25例年龄匹配健康对照;二维螺旋序列采集超极化氙-129 MRI;采用N4或翻转角(FA)偏倚校正;以读者分割VDP为参考,比较MeanGLB与五种自动方法。

关键影像表现/征象

  • N4校正图像上,除Hierarchical外所有方法在囊性纤维化患者与健康对照间VDP差异显著(P<0.05)。
  • FA校正图像上,除Hierarchical和Adaptive外所有方法在两组间VDP差异显著(P<0.05)。
  • MeanGLB在囊性纤维化患者中高估缺陷,N4校正图像Bland-Altman偏倚-3.1%,FA校正图像偏倚-1.9%。

诊断标准与关键数值

  • MeanGLB与读者分割VDP强相关:N4和FA校正图像r=0.97,P<0.001。
  • MeanGLB在N4和FA校正图像上Youden指数约0.75,为所有方法中最高。
  • 以读者分割缺陷图为参考,采用敏感度、特异度和Youden指数评估体素一致性。

临床应用与阅片要点

  • MeanGLB可用于氙-129通气MRI的VDP定量,且不依赖N4或FA偏倚校正算法的选择。
  • MeanGLB在囊性纤维化患者中可能高估缺陷百分比(N4校正偏倚-3.1%,FA校正偏倚-1.9%),判读时需结合读者分割结果。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Hyperpolarized xenon-129 (129Xe) MRI is an established, sensitive method to assess ventilation but lacks a standardized ventilation defect quantification. We introduce mean-anchored generalized linear binning (MeanGLB, GLB) to calculate ventilation defect percentage (VDP), benchmarking its performance against reader-segmented VDP (Reader) and five widely-used automated VDP calculation methods.

MATERIALS AND METHODS: 129Xe images were acquired from 38 people with cystic fibrosis (CF) and 25 age-matched healthy controls (HCs) using 2D-spiral sequence. Flexible chest coil-induced inhomogeneities were mitigated using both N4- or a flip-angle (FA)-based bias correction. VDP was quantified using Reader, Hierarchical and Adaptive K-means clustering, mean-normalized linear binning, 99th Percentile-normalized GLB, binary Thresholding, and MeanGLB; and compared for all techniques. Additionally, VDPs obtained via automated methods were evaluated against Reader. Voxel-wise agreement with Reader-based defect maps was assessed using sensitivity, specificity and Youden's index.

RESULTS: Using N4-corrected images, all methods-except Hierarchical-showed significant difference in VDP between participants with CF and HCs (P<0.05). For FA-corrected images, similar significance was observed for all methods (P<0.05), except Hierarchical and Adaptive. While MeanGLB overestimated defects in participants with CF, for both N4- and FA-corrected images (Bland-Altman biases: -3.1% and -1.9%, respectively), it strongly correlated with Reader (r=0.97, P<0.001 both). MeanGLB achieved the highest Youden's index (∼0.75) across N4- and FA-corrected images, indicating balance of sensitivity and specificity.

CONCLUSION: MeanGLB enabled robust quantification of VDP in 129Xe ventilation MRI, independent of bias-correction algorithm. Its ability to capture subtle impairments indicates its potential for applications in pulmonary imaging.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Hussain R, Bdaiwi AS, Plummer JW, et al. Comparing Mean-anchored Generalized Linear Binning with Established Methods to Quantify Xenon-129 Ventilation Defect Percentage. Acad Radiol. 2025. PMID: 41241593. doi:10.1016/j.acra.2025.10.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。