文献速递儿科影像技术与安全US

使用超声回声标记物对单个宫内胎鼠进行纵向超声成像

Longitudinal Ultrasound Imaging of an Individual Fetus In Utero Using an Echogenic Marker.
PubMed 文献 · Ultrasound Med Biol · 2025-11-13

本研究在胚胎第14.5天经超声引导向羊膜腔内注射由玻璃微球和剪切稀化生物材料组成的回声标记物,以纵向追踪单个小鼠胎儿至足月(E18.5),并重复测量脐动脉血流和胎肺体积;该方法对胎儿和孕鼠安全,未增加死亡率,结合已有小鼠妊娠模型可实现可靠的纵向数据采集。

要点

  • 经超声引导羊膜腔注射玻璃微球与剪切稀化生物材料组成的回声标记物,可在E14.5标记并纵向追踪单个胎鼠至E18.5。
  • 被追踪胎鼠的脐动脉流速和血管直径等关键诊断参数可在E14.5至足月期间重复测量。
  • 该方法对胎鼠和孕鼠安全,未增加死亡率。

核心结论

  • 将这种小鼠胎儿追踪方法与已有妊娠相关及妊娠期病症小鼠模型结合,是进行小鼠胎儿纵向数据采集的可靠方法。

研究设计与样本

  • 研究在CD-1品系小鼠中于胚胎第14.5天经超声引导行羊膜腔内注射回声标记物,并纵向追踪至足月(E18.5)。
  • 研究采集脐动脉血流纵向测量以评估在胎儿研究中开展可行实验的可行性,并采集胎肺体积以评估羊膜腔注射及操作的安全性。

诊断标准与关键数值

  • 被追踪胎鼠的脐动脉流速和血管直径等关键诊断参数可在E14.5至足月(E18.5)期间重复测量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: High frequency ultrasound imaging has become an important tool for the study of pregnancy disorders in mouse models as it enables detailed, noninvasive characterization of in utero development. However, the need to reliably identify individual fetuses over time presents a challenge when using this approach for longitudinal assessments. Large litter sizes and frequently changing fetal positions within the abdomen across gestation have the potential to confound such measurements.

METHOD: The current study presents a minimally invasive method to longitudinally track a specific mouse fetus through late gestation using ultrasound-guided intra-amniotic injections of an echogenic marker comprised of glass microspheres and shear thinning biomaterial, on embryonic day (E)14.5. Longitudinal measurements of the umbilical artery blood flow were gathered to assess feasibility of a plausible experiment in fetal research. Fetal lung volumes were collected to assess safety of the intra-amniotic sac injection and procedure as amniotic fluid loss during injection risks underdeveloped lungs.

RESULTS: Using CD-1 strain mice, we show that key diagnostic parameters such as umbilical artery velocity and vessel diameter, can be repeatedly measured in the tracked fetus from E14.5 through to term (E18.5). The method is safe for the fetus and pregnant dam with no increased mortality.

CONCLUSION: Combining this method of mouse fetal tracking with established mouse models of pregnancy-related and gestational conditions proves to be a reliable method for longitudinal data collection in mouse fetuses.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Tan R, Debebe SK, Botelho O, et al. Longitudinal Ultrasound Imaging of an Individual Fetus In Utero Using an Echogenic Marker. Ultrasound Med Biol. 2025. PMID: 41233189. doi:10.1016/j.ultrasmedbio.2025.10.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。