文献速递胸部CT

四维计算机断层扫描在呼气性中央气道塌陷中的应用:颠覆诊断范式

Four-dimensional computed tomography in expiratory central airway collapse: Disrupting diagnostic paradigms.
PubMed 文献 · Eur J Radiol · 2025-11-17

本研究回顾性比较静态呼气末、静态用力呼气与四维用力呼气三种胸部CT方案与动态支气管镜(金标准)诊断呼气性中央气道塌陷的一致性,共纳入96例患者;四维用力呼气方案与支气管镜一致性最高(Kappa 0.735),检测塌陷敏感度92.5%,中位辐射剂量最低(530.0 mGy-cm)。

要点

  • 四维用力呼气CT与动态支气管镜诊断一致性最高,Kappa为0.735。
  • 四维用力呼气CT检测塌陷敏感度92.5%,识别重度病变敏感度65.6%。
  • 三种方案中四维用力呼气CT中位辐射剂量最低,为530.0 mGy-cm。

核心结论

  • 四维用力呼气方案与金标准动态支气管镜诊断呼气性中央气道塌陷的相关性最高,且辐射剂量低于静态呼气CT方案。

研究设计与样本

  • 回顾性研究,共纳入96例患者(中位年龄64岁,中位BMI 32.1 kg/m2,女性占71%),比较静态呼气末、静态用力呼气与四维用力呼气三种胸部CT方案,以动态支气管镜为参考标准。

诊断标准与关键数值

  • 以动态支气管镜观察的塌陷百分比为参考,计算胸部CT塌陷指数;四维用力呼气方案与支气管镜一致性Kappa为0.735(高度一致),静态用力呼气方案Kappa为0.248(一般一致),静态呼气末方案Kappa为0.187(轻微一致);四维用力呼气方案检测塌陷敏感度92.5%,识别重度病变敏感度65.6%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Expiratory central airway collapse (ECAC) is an under-recognized condition, currently diagnosed by the gold standard dynamic bronchoscopy. Several expiratory chest CT protocols have been used for the initial workup of ECAC with variable accuracy. We compared three expiratory chest CT protocols to determine which one holds the closest correlation with dynamic bronchoscopy to detect ECAC.

MATERIALS AND METHODS: We performed a retrospective study of patients who underwent either static end expiratory (SEE), static forced expiratory (SFE), or four-dimensional forced expiratory (4D-FE) CT for the evaluation of ECAC and a confirmatory dynamic bronchoscopy. Chest CT collapsibility index was calculated and compared to the percentage of collapsibility observed during dynamic bronchoscopy using Cohen's Kappa coefficient and diagnostic accuracy assessment.

RESULTS: A total of 96 patients were reviewed (median age: 64 years; median BMI: 32.1 kg/m2; 71 % female). Kappa's coefficient of agreement was 0.735 (substantial agreement) for the 4D-FE protocol, 0.248 (fair agreement) for the SFE protocol, and 0.187 (slight agreement) for the SEE protocol, with dynamic bronchoscopy. The 4D-FE protocol presented the highest sensitivity for detecting ECAC (92.5 %) and identifying severe disease (65.6 %), and the lowest median radiation exposure (530.0 mGy-cm) among the three imaging protocols.

CONCLUSION: The 4D-FE protocol showed the highest correlation with the gold standard dynamic bronchoscopy for the diagnosis of ECAC and required less radiation exposure than the static expiratory CT protocols.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Abia-Trujillo D, Yu Lee-Mateus A, Stowell JT, et al. Four-dimensional computed tomography in expiratory central airway collapse: Disrupting diagnostic paradigms. Eur J Radiol. 2025. PMID: 41289725. doi:10.1016/j.ejrad.2025.112536

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。