2020年血管外科学会/胸外科学会无并发症B型主动脉夹层报告标准的可重复性
本研究回顾性分析37例急性无并发症B型主动脉夹层患者的CT血管造影,由14名心血管影像科医生和外科医生按2020年SVS/STS报告标准分区,评估读者间和读者内一致性。结果显示入口撕裂和近端范围的一致性差至中等,远端范围一致性中等至好;差异原因包括主动脉分区定义不清、病变解剖复杂和图像质量差。结论认为该标准在经验丰富的读者中可重复性差。
要点
- 入口撕裂的读者间一致性为一般(κ=0.33、0.40、0.22、0.40),近端范围为差至中等(κ=0.30、0.37、0.20、0.41)。
- 远端夹层范围一致性中等至好(κ=0.65、0.80、0.41、0.77),优于入口撕裂和近端范围。
- 分类差异主要源于主动脉分区定义不清、病变解剖复杂和图像质量差。
核心结论
- 2020年SVS/STS报告标准在急性无并发症B型主动脉夹层中于经验丰富的心血管影像科医生和外科医生间可重复性差。
研究设计与样本
- 回顾性研究,纳入2001年1月至2013年12月间37例急性无并发症B型主动脉夹层患者(平均年龄48.5岁±15.6,24例男性)的CT血管造影,由14名心血管影像科医生和外科医生(8名放射科医生、4名心胸外科医生、2名血管外科医生)独立评估。
诊断标准与关键数值
- 按2020年SVS/STS报告标准将入口撕裂及夹层近端和远端范围分配至主动脉分区;读者间一致性:入口撕裂κ=0.33、0.40、0.22、0.40,近端范围κ=0.30、0.37、0.20、0.41,远端范围κ=0.65、0.80、0.41、0.77;个体间入口撕裂κ=0.04-0.71(78%不一致),近端范围κ=0.00-0.62(68%不一致),远端范围κ=0.33-0.92(35%不一致);读者内入口撕裂κ=0.41-0.57,近端范围κ=0.37-0.58,远端范围κ=0.66-0.92。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To assess the inter- and intrareader agreement of the 2020 Society for Vascular Surgery/Society of Thoracic Surgeons (SVS/STS) reporting standards in patients with acute uncomplicated type B aortic dissection (uTBAD). Materials and Methods CT angiograms, obtained between January 2001 and December 2013, from 37 patients (mean age ± SD, 48.5 years ± 15.6; 24 male) with uTBAD were retrospectively reviewed by 14 cardiovascular radiologists and surgeons. The entry tear and proximal and distal extent of each dissection were allocated to aortic zones according to the 2020 SVS/STS reporting standards. Inter- and intrareader agreement was assessed using Cohen κ. Causes of discrepant classifications were analyzed. Results Interreader agreement among all 14 readers (eight radiologists, four cardiothoracic surgeons, and two vascular surgeons) were fair for the entry tear (к = 0.33, 0.40, 0.22, and 0.40), poor to moderate for the proximal extent (к = 0.30, 0.37, 0.20, and 0.41), and moderate to substantial for the distal dissection extent (к = 0.65, 0.80, 0.41, and 0.77). Interreader agreement between individuals was poor to substantial for the entry tear (к = 0.04-0.71; 78% discrepancy) and proximal extent (к = 0.00-0.62; 68% discrepancy), and fair to excellent for the distal extent (к = 0.33-0.92; 35% discrepancy). The causes for discrepancies were unclear definitions of aortic zones, anatomic complexity of lesions, and poor image quality. Intrareader agreement was moderate for the entry tear (к = 0.41-0.57), fair to moderate for the proximal extent (к = 0.37-0.58), and substantial to excellent for the distal extent (к = 0.66-0.92). Conclusion The 2020 SVS/STS reporting standards for acute uTBAD were poorly reproducible among experienced cardiovascular radiologists and surgeons. Keywords: Vascular, Aorta, Dissection, Aortic Dissection, SVS/STS Reporting Standards, CT Angiography, Interobserver Study, Intraobserver Study Supplemental material is available for this article. © RSNA, 2025.
引用
- Sriprachyakul A, Mastrodicasa D, Willemink MJ, et al. Reproducibility of the 2020 Society for Vascular Surgery/Society of Thoracic Surgeons Reporting Standards for Uncomplicated Type B Aortic Dissection. Radiol Cardiothorac Imaging. 2025. PMID: 41231129. doi:10.1148/ryct.240325
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。