文献速递头颈神经MR

单剂量钆对比剂后多翻转角MR前瞻性评估内淋巴积水

Prospective MR Evaluation of Endolymphatic Hydrops at Multiple Flip Angles Using Single-Dose Gadolinium Contrast.
PubMed 文献 · AJNR Am J Neuroradiol · 2025-12-04

前瞻性纳入16例按2015年AAO-HNS标准诊断的梅尼埃病患者,在单剂量钆对比剂静脉注射4小时后行3T延迟内耳MRI,比较恒定翻转角120°、140°与可变翻转角三种3D-FLAIR方案的图像质量,结果显示CFA 140°的信噪比与对比噪声比最高、内淋巴积水等结构显示最佳。

要点

  • 单剂量钆对比剂静脉注射4小时后3T延迟内耳MRI可评估内淋巴积水。
  • CFA 140°的外淋巴腔SNR与内淋巴腔CNR显著高于CFA 120°和VFA(P<.05)。
  • CFA 140°显示内淋巴积水、椭圆囊-球囊复合体及血-迷路屏障通透性显著更佳(P<.05)。

核心结论

  • 3T下单剂量静脉钆对比剂结合CFA 140°的3D-FLAIR内耳成像似乎是检测内淋巴积水的可靠方法。

研究设计与样本

  • 前瞻性头对头比较研究,连续纳入16例符合2015年美国耳鼻咽喉头颈外科学会梅尼埃病标准的患者,于单剂量钆对比剂静脉注射4小时后行3T延迟内耳MRI,比较CFA 120°、CFA 140°与VFA三种翻转角。

关键影像表现/征象

  • CFA 140°的外淋巴腔SNR与内淋巴腔CNR显著高于CFA 120°,CFA 120°又高于VFA(P<.05)。
  • CFA 140°对内淋巴积水、椭圆囊-球囊复合体及血-迷路屏障通透性的显示显著改善(P<.05)。
  • 两位头颈神经放射科医师评估的观察者间一致性极好(κ>0.80)。

诊断标准与关键数值

  • 共分析31耳,其中17耳有症状、14耳无症状;1耳因既往左侧迷路切除术后被排除。
  • 以2015年美国耳鼻咽喉头颈外科学会标准诊断梅尼埃病,包括急性或波动性眩晕、听力下降、耳鸣或耳闷胀感症状。

临床应用与阅片要点

  • 采用单剂量钆对比剂静脉注射后4小时行3T延迟内耳3D-FLAIR成像,CFA 140°在显示内淋巴积水、椭圆囊-球囊复合体及血-迷路屏障通透性方面优于CFA 120°和VFA。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Technical advancements in inner ear MRI promise improved diagnosis and management of Ménière disease (MD), but a key challenge in optimizing 3D-FLAIR protocols for inner ear imaging lies in selecting the optimal flip angle. This study evaluates the 3 most common flip angle parameters used in 3D-FLAIR imaging for MD through a prospective, head-to-head comparison of image quality at constant flip angle (CFA) 120°, CFA 140°, and variable flip angle (VFA) obtained 4 hours after IV administration of a single-dose gadolinium-based contrast agent.

MATERIALS AND METHODS: We prospectively enrolled 16 consecutive patients at our institution's otology clinic on the basis of the 2015 American Academy of Otolaryngology-Head and Neck Surgery criteria for MD, including acute or fluctuating symptoms of vertigo, hearing loss, tinnitus, or aural fullness. Each patient underwent delayed inner ear MRI at 3T with the 3 most commonly used flip angles: CFA 120°, CFA 140°, and VFA. The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were determined for each flip angle. Assessment of blood-labyrinthine barrier (BLB) permeability, utricle-saccule discrimination, and endolymphatic hydrops (EH) was performed by 2 head and neck neuroradiologists.

RESULTS: Thirty-one ears were analyzed. One ear was excluded on the basis of a prior history of left labyrinthectomy after failed medical management of MD. There were 17 symptomatic and 14 asymptomatic ears determined by clinical and hearing evaluation. The SNR of the perilymphatic space and CNR of the endolymphatic space were significantly higher at CFA 140°, followed by CFA 120°, and then VFA (P < .05). There was significantly improved visualization of EH, the utricle-saccule complex, and BLB permeability at CFA 140° (P < .05), with excellent interobserver agreement (κ > 0.80).

CONCLUSIONS: Our study demonstrates that 3D-FLAIR inner ear imaging using CFA 140° and single-dose IV gadolinium contrast at 3T is a reliable method for detecting EH.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Pham N, Kullar P, Fischbein N, et al. Prospective MR Evaluation of Endolymphatic Hydrops at Multiple Flip Angles Using Single-Dose Gadolinium Contrast. AJNR Am J Neuroradiol. 2025. PMID: 41298110. doi:10.3174/ajnr.A8880

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。