弥散加权成像与表观弥散系数参数鉴别脑脓肿与恶性环形强化脑病变的诊断效能:系统综述与Meta分析
该系统综述与Meta分析纳入34项研究(恶性环形强化脑病变1382例、脑脓肿1061例),评估DWI与ADC鉴别二者的诊断效能。恶性环形强化脑病变的汇总ADC值为1797.17×10⁻⁶ mm²/s,脑脓肿为852.07×10⁻⁶ mm²/s,前者较后者高116%;定性评估DWI与ADC参数的汇总敏感度92%、特异度92%、AUC 0.97。作者结论认为DWI是鉴别脑脓肿与恶性环形强化脑病变的有价值诊断工具。
要点
- 恶性环形强化脑病变汇总ADC为1797.17×10⁻⁶ mm²/s,脑脓肿为852.07×10⁻⁶ mm²/s,前者高116%。
- DWI与ADC参数鉴别脑脓肿与恶性环形强化脑病变的汇总敏感度92%、特异度92%、AUC 0.97。
- ADC比较的汇总标准化均数差为3.12(95%CI 2.32-3.91),异质性I²=96.8%,P<0.001。
核心结论
- DWI是鉴别脑脓肿与恶性环形强化脑病变的有价值诊断工具,具有高敏感度、高特异度,且两组间ADC差异显著。
研究设计与样本
- 系统综述与Meta分析,方案预先注册于https://osf.io/mjwek。
- 检索PubMed、Embase和Web of Science截至2025年4月5日,纳入使用DWI鉴别恶性环形强化脑病变与脑脓肿的研究。
- 共纳入34项研究,含恶性环形强化脑病变1382例和脑脓肿1061例;纳入研究的偏倚风险采用QUADAS-2评估。
- ADC比较采用随机效应模型,计算AUC、敏感度和特异度,并进行敏感度分析、发表偏倚检验和亚组分析。
诊断标准与关键数值
- 恶性环形强化脑病变汇总ADC值为1797.17×10⁻⁶ mm²/s(95%CI 1446.55-2147.80),脑脓肿为852.07×10⁻⁶ mm²/s(95%CI 786.52-917.61)。
- 恶性环形强化脑病变ADC较脑脓肿高116%,汇总标准化均数差为3.12(95%CI 2.32-3.91,I²=96.8%,P<0.001)。
- 定性评估DWI与ADC参数鉴别脑脓肿与恶性环形强化脑病变的汇总敏感度为92%(95%CI 89%-95%),特异度为92%(95%CI 89%-94%),AUC为0.97(95%CI 0.95-0.98)。
局限性
- ADC比较的汇总标准化均数差异质性I²=96.8%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the performance of diffusion-weighted imaging (DWI) and apparent diffusion coefficients (ADC) in the differentiation of brain abscesses (BA) from malignant ring-enhancing brain lesions (REBL).
METHODS: The protocol was pre-registered at (https://osf.io/mjwek). We conducted a comprehensive search in PubMed, Embase, and Web of Science until April 5, 2025, for studies that used DWI for differentiation of malignant REBLs from BAs. The risk of bias in the included studies was evaluated using QUADAS-2. ADC were compared between malignant REBLs and BAs using a random-effects model. Diagnostic values of area under the curve (AUC), sensitivity, and specificity were calculated. Sensitivity analysis, publication bias tests, and subgroup analysis were performed.
RESULTS: Thirty-four studies were included with 1382 malignant REBL and 1061 abscesses. The pooled ADC values of malignant REBL and BA were 1797.17 × 10-6 mm2/s (95 % CI: 1446.55-2147.80) and 852.07 × 10-6 mm2/s (95 % CI: 786.52-917.61). Malignant REBLs had 116 % higher ADCs than BAs with a significant pooled standardized mean difference of 3.12 (95 % CI: 2.32-3.91, I2 = 96.8 %, p < 0.001). Qualitative assessment of DWI and ADC parameter demonstrated a pooled sensitivity of 92 % (95 % CI: 89 %-95 %), specificity of 92 % (95 % CI: 89 %-94 %), and AUC of 0.97 (95 % CI: 0.95-0.98) for differentiating BAs from malignant REBLs.
CONCLUSION: DWI provides a valuable diagnostic tool for differentiating BAs from malignant REBLs, demonstrating high sensitivity, specificity, and significant ADC difference between the two groups.
引用
- Moradi Z, Mohammadzadeh S, Mohebbi A, et al. Diagnostic Performance of DWI and ADC Parameter in Differentiating Brain Abscess from Malignant Ring-Enhancing Brain Lesions: A Systematic Review and Meta-analysis. Eur J Radiol. 2025. PMID: 41317570. doi:10.1016/j.ejrad.2025.112531
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。