文献速递儿科影像神经MR

优化婴儿磁共振成像效率:深度学习辅助喂奶包裹技术与全身麻醉在使用婴儿磁共振稳定器下对4个月以下婴儿的比较

Optimizing infant magnetic resonance imaging efficiency: Deep learning-assisted feed-and-wrap technique versus general anesthesia using an infant magnetic resonance imaging stabilizer in infants under 4 months.
PubMed 文献 · Pediatr Radiol · 2025-11-06

单中心回顾性研究纳入48例≤4个月婴儿脑MRI,比较深度学习辅助喂奶包裹技术(DL-FW,n=22)与全身麻醉(GA,n=26)的检查室周转时间,DL-FW组中位周转时间23分钟 vs GA组30分钟,差异显著(P=0.013),Hodges-Lehmann估计GA较DL-FW多6分钟(95%CI 2-11)。

要点

  • DL-FW组MRI检查室中位周转时间23分钟,GA组30分钟,DL-FW缩短约7分钟。
  • 两组周转时间差异有统计学意义(U=166,z=-2.48,P=0.013)。
  • Hodges-Lehmann估计GA周转时间较DL-FW多6分钟(95%CI 2-11)。

核心结论

  • 在≤4个月婴儿中,使用婴儿MRI稳定器的DL-FW路径与GA相比,MRI检查室周转时间显著缩短,支持DL-FW作为一种保留麻醉的方法,可能改善工作流程和安全性。

研究设计与样本

  • 单中心回顾性研究,纳入连续≤4个月接受脑MRI且符合预设标准的婴儿48例(DL-FW组n=22,GA组n=26),按机构惯例选择DL-FW或GA,主要终点为MRI检查室周转时间。

诊断标准与关键数值

  • DL-FW组周转时间中位数23分钟(IQR 21-27),均值±标准差26.8±11.3,范围14-52。
  • GA组周转时间中位数30分钟(IQR 27-38),均值±标准差32.6±9.8,范围19-58。
  • 组间比较U=166,z=-2.48,P=0.013;Hodges-Lehmann估计GA周转时间较DL-FW多6分钟(95%CI 2-11),组中位数减少7分钟(相对GA约23%)。

局限性

  • 原文为单中心回顾性研究。
  • 原文未报告样本量估算或随访信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Infant MRI is limited by motion and the frequent reliance on general anesthesia (GA), which suppresses motion but increases procedural risk, resource use, and turnover time. A sedation-free alternative is the feed-and-wrap (FW) technique-natural sleep supported by swaddling and noise control-which avoids anesthesia but can be limited by motion and variable success. Deep-learning (DL)-based image reconstruction shortens acquisitions and improves image quality, potentially strengthening the FW pathway (DL-FW) by reducing scan time and repeat sequences.

OBJECTIVE: Our study aimed to investigate whether, compared with GA, DL-FW reduces MRI turnover time in infants younger than 4 months.

MATERIALS AND METHODS: In this single-center retrospective study, we included consecutive infants aged ≤4 months who underwent brain MRI during the study period and met predefined criteria. Infants underwent either DL-FW or GA according to institutional practice. The primary endpoint was the turnover time of the MRI room, defined as the interval from the starting point to the end of the procedure. Times are summarized as median (IQR) and mean±SD; groups were compared using a two-sided Mann-Whitney U test (α=0.05). The between-group shift was estimated with the Hodges-Lehmann (HL) estimator and 95% confidence interval (CI).

RESULTS: Forty-eight infants were analyzed (DL-FW n=22; GA n=26). Turnover time was shorter with DL-FW (23 min [21-27], mean±SD 26.8±11.3, range 14-52) versus GA (30 min [27-38], 32.6±9.8, 19-58), and the difference was significant (U=166; z= - 2.48; P=0.013). The HL estimator indicated that the GA turnover time exceeded that of DL-FW by 6 min (95% CI 2-11), corresponding to a 7-min reduction in group medians (~23% relative to GA). No data were missing.

CONCLUSION: In infants aged ≤4 months, a DL-FW pathway with an infant MRI stabilizer was associated with significantly shorter MRI room turnover time than GA was, supporting the use of DL-FW as an anesthesia-sparing approach that may improve workflow and safety.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Aldraihem A, Almaimani M, Bayoumi M, et al. Optimizing infant magnetic resonance imaging efficiency: Deep learning-assisted feed-and-wrap technique versus general anesthesia using an infant magnetic resonance imaging stabilizer in infants under 4 months. Pediatr Radiol. 2025. PMID: 41193818. doi:10.1007/s00247-025-06437-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。