文献速递神经MR

基于MRI的深度学习算法检测急性缺血性卒中的效能:在不同阅片者中的评估

Efficacy of MRI-based deep learning algorithm for detecting acute ischemic stroke: evaluation among diverse readers.
PubMed 文献 · Eur Radiol · 2025-11-17

这项回顾性、多阅片者、多病例交叉研究纳入407例MRI扫描(95例急性缺血性卒中,占23%),评估基于MRI的深度学习算法(DLA)对放射科住院医师、无放射培训的临床医生及非神经放射专科认证医师检测急性缺血性卒中的辅助效能。DLA显著提高临床医生的AUC(0.90→0.93)、敏感度(0.77→0.88)和诊断信心(0.71→0.83),并改善所有阅片者间的一致性;对住院医师和非神经放射专科医师的效能及临床医生的特异度无显著影响。

要点

  • DLA使临床医生检测AIS的AUC从0.90升至0.93、敏感度从0.77升至0.88、诊断信心从0.71升至0.83(均p<0.01)。
  • DLA显著改善所有阅片者间的一致性(p<0.01)。
  • 临床医生特异度从0.95降至0.93(p=0.55),住院医师和非神经放射专科医师效能无显著变化。

核心结论

  • DLA显著改善了临床医生(表现最低的阅片者)诊断AIS的效能和诊断信心,并显著提高了所有阅片者间的一致性。

研究设计与样本

  • 回顾性、多阅片者、多病例交叉研究,纳入单中心2021年4月至6月获得的407例MRI扫描,95例为AIS(23%);9名不同背景阅片者(放射科住院医师、临床医生、非神经放射专科认证医师)分别在有和无DLA检测概率下独立阅片,以3名神经放射专科医师共识为参考标准。

诊断标准与关键数值

  • 以3名神经放射专科医师共识为参考标准;临床医生使用DLA后AUC从0.90(95%CI 0.82-0.99)升至0.93(95%CI 0.87-0.99)(p<0.01),敏感度从0.77(95%CI 0.65-0.88)升至0.88(95%CI 0.75-0.99)(p<0.01)。

临床应用与阅片要点

  • 临床医生使用DLA后诊断信心从0.71±1.42升至0.83±1.53(p<0.01);DLA改善所有阅片者间一致性(p<0.01)。

局限性

  • 本研究为回顾性研究。
  • 研究纳入单中心2021年4月至6月的MRI扫描。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The efficacy of an MRI-based deep learning algorithm (DLA) for detecting acute ischemic stroke (AIS) was evaluated across readers with diverse medical backgrounds, because DLA performance may be user-dependent.

MATERIALS AND METHODS: This retrospective, multi-reader, multi-case crossover study included 407 MRI scans obtained from a single institution between April and June 2021. Nine readers with different backgrounds- radiology residents (1-2 years of radiology training), clinicians (no radiology training), and board-certified non-neuroradiologists (completed residency training)-independently read MRI scans, both with and without DLA detection probability. The ground truth was established by consensus among three neuroradiologists. The area under the receiver operating characteristic curve (AUC), accuracy, sensitivity, specificity, diagnostic confidence (0-4), and inter-reader agreement were compared between the groups with and without DLA.

RESULTS: In total, 407 patients (mean age, 66 years ± 16; 200 men) with 95 AIS (23%) were evaluated. Clinicians had the lowest baseline performance scores. The DLA significantly improved clinicians' AUC (from 0.90 [95% CI: 0.82-0.99]; to 0.93 [0.87-0.99]; p < 0.01), sensitivity (from 0.77 [0.65-0.88]; to 0.88 [0.75-0.99]; p < 0.01), and diagnostic confidence (from 0.71 ± 1.42; to 0.83 ± 1.53; p < 0.01), and all readers' inter-reader agreement (p < 0.01). Specificity for clinicians (from 0.95 [0.86-0.99] to 0.93 [0.80-0.99]; p = 0.55) and the performance of residents and non-neuroradiologists were not significantly affected by DLA assistance.

CONCLUSION: The DLA significantly improved the performance and diagnostic confidence of clinicians, the lowest-performing readers, and the inter-reader agreement of all readers in diagnosing AIS.

KEY POINTS: Question What is the efficacy of an MRI-based deep learning algorithm in assisting various medical professionals in identifying acute ischemic stroke? Findings Among radiology residents, clinicians, and board-certified non-neuroradiologists, the algorithm significantly improved clinicians' performance and diagnostic confidence while also enhancing inter-reader agreement for all readers. Clinical relevance The deep learning algorithm significantly improves the detection performance and diagnostic confidence of clinicians, the lowest-performing readers, for acute ischemic stroke. Furthermore, the inter-reader agreement among various medical professionals has improved significantly.

来源:Eur Radiol,查看原文。版权归原作者所有。