颅内动脉斑块联合脑小血管病磁共振特征评估缺血性卒中
回顾性分析2021年9月至2024年10月112例颅内动脉粥样硬化患者的临床与影像资料,由两名放射科医师评估颅内动脉粥样硬化病(ICAD)和脑小血管病(CSVD)特征。多因素logistic回归显示斑块强化指数(OR 4.250,95%CI 2.023-8.929)及腔隙性脑梗死合并中重度白质高信号(OR 4.940,95%CI 1.477-16.516)与卒中相关;两者联合评估卒中的AUC为0.776,高于单一ICAD特征(斑块强化指数AUC 0.736)或单一CSVD特征(腔隙性脑梗死合并中重度白质高信号AUC 0.603)。
要点
- 斑块强化指数与卒中独立相关(OR 4.250,95%CI 2.023-8.929)。
- 腔隙性脑梗死合并中重度白质高信号与卒中独立相关(OR 4.940,95%CI 1.477-16.516)。
- 联合ICAD与CSVD特征的AUC为0.776,敏感度73.0%、特异度73.7%。
核心结论
- 基于高分辨血管壁成像,联合ICAD和CSVD的磁共振特征评估卒中的价值高于单一ICAD特征或单一CSVD特征。
研究设计与样本
- 回顾性分析2021年9月至2024年10月112例颅内动脉粥样硬化患者的临床和影像资料,两名放射科医师分析ICAD和CSVD特征,采用单因素和多因素logistic回归筛选与卒中独立相关的因素,并用AUC评估诊断效能。
关键影像表现/征象
- 斑块强化指数与卒中显著相关(OR 4.250,95%CI 2.023-8.929)。
- 腔隙性脑梗死合并中重度白质高信号与卒中显著相关(OR 4.940,95%CI 1.477-16.516)。
诊断标准与关键数值
- 斑块强化指数评估卒中的AUC为0.736(P<0.001)。
- 腔隙性脑梗死合并中重度白质高信号评估卒中的AUC为0.603(95%CI 0.496-0.709,P=0.046)。
- 斑块强化指数联合腔隙性脑梗死合并中重度白质高信号评估卒中的AUC为0.776(P<0.001),敏感度73.0%,特异度73.7%。
临床应用与阅片要点
- 阅片时可同时评估颅内动脉斑块强化指数及腔隙性脑梗死、中重度白质高信号等CSVD特征。
- 联合ICAD与CSVD特征评估卒中(AUC 0.776)的诊断效能高于单一斑块强化指数(AUC 0.736)或单一腔隙性脑梗死合并中重度白质高信号(AUC 0.603)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To explore whether imaging features of intracranial atherosclerotic disease (ICAD) and cerebral small vessel disease (CSVD) are associated with ischaemic stroke based on high-resolution vessel wall imaging and to evaluate whether combining the two disease features to assess ischaemic stroke has a higher diagnostic efficacy.
MATERIALS AND METHODS: Clinical and imaging data of 112 patients with intracranial atherosclerosis collected between September 2021 and October 2024 were retrospectively analysed. Two radiologists analysed ICAD and CSVD characteristics. Univariate and multivariate logistic regression was used to identify factors independently associated with stroke. The diagnostic efficacy was evaluated using the area under the curve (AUC).
RESULTS: Multivariate logistic regression analysis revealed significant correlations between plaque enhancement index (odds ratio [OR]: 4.250, 95 % CI: 2.023-8.929), lacunar infarction combined with moderate-to-severe white matter hyperintensity (OR: 4.940, 95 % CI: 1.477-16.516), and stroke. The AUC for lacunar infarction combined with moderate-to-severe white matter hyperintensity was 0.603 (95 % CI: 0.496-0.709, P=0.046). The AUC of the plaque enhancement index was 0.736 (P<0.001). The AUC for combining these two indexes was 0.776 (P<0.001), with a sensitivity of 73.0 % and a specificity of 73.7 %.
CONCLUSION: MRI features combining ICAD and CSVD have a higher value in assessing stroke than single ICAD features or single CSVD features.
引用
- Liu J, Ouyang F, Wu Q, et al. Intracranial arterial plaque combined with cerebral small vessel disease magnetic resonance features to assess ischemic stroke. Clin Radiol. 2025. PMID: 41237711. doi:10.1016/j.crad.2025.107131
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。