文献速递神经外周血管头颈CT

超越影像特征:双能CT揭示卒中与非卒中患者高危斑块的细微差异

Beyond Imaging Features: Dual-Energy CT Reveals Subtle Differences in High-Risk Plaques Between Stroke and Non-stroke Patients.
PubMed 文献 · Acad Radiol · 2025-11-29

这项回顾性研究纳入87例非狭窄性颈动脉斑块患者共216个斑块,行双能CT血管成像,比较卒中组与非卒中组斑块的传统参数与光谱参数。结果显示每增加一个高危特征使卒中风险增加54%,最大壁厚度和低衰减斑块厚度每增加1 mm分别增加73%和62%的风险。双能CT光谱参数在140 keV下卒中组斑块衰减值显著更低,斑块低衰减区截断值33.5 HU时特异度为0.952。

要点

  • 双能CT 140 keV下卒中组低衰减斑块衰减值显著低于非卒中组(22.2±8.8 vs 32.3±12.1 HU)。
  • 低衰减斑块140 keV诊断AUC为0.750,截断值33.5 HU时特异度0.952。
  • 每增加一个高危特征,急性缺血性卒中风险增加54%。

核心结论

  • 影像学表现相似的非狭窄性颈动脉斑块在卒中与非卒中患者间存在细微差异,双能CT参数可量化超出传统形态学的差异,这些参数可作为卒中相关生物标志物,为未来预测工具和临床决策提供方向与基础。

研究设计与样本

  • 回顾性研究,纳入87例非狭窄性颈动脉斑块患者共216个斑块,分为急性缺血性卒中组(37例,85个斑块)与非卒中组,所有患者行双能CT血管成像,分析传统斑块参数与双能CT光谱参数,采用逻辑回归计算比值比,并以受试者工作特征曲线评价诊断效能。

关键影像表现/征象

  • 卒中组与非卒中组在常规影像上斑块表现相似,但双能CT光谱参数存在差异。
  • 140 keV下卒中组餐巾环征斑块衰减值为22.1±7.8 HU,非卒中组为29.6±10.4 HU,卒中组更低。
  • 140 keV下卒中组低衰减斑块衰减值为22.2±8.8 HU,非卒中组为32.3±12.1 HU,卒中组更低。

诊断标准与关键数值

  • 140 keV下餐巾环征诊断卒中的AUC为0.723。
  • 140 keV下低衰减斑块诊断卒中的AUC为0.750,截断值33.5 HU时特异度为0.952。

临床应用与阅片要点

  • 对非狭窄性颈动脉斑块行双能CT血管成像时,可关注140 keV下斑块衰减值以辅助识别卒中相关高危斑块。
  • 餐巾环征和低衰减斑块在140 keV下的衰减值可作为超出传统形态学的补充量化指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

UNLABELLED: RATIONALE AND OBJECTIVES: A critical challenge is identifying why some high-risk plaques cause stroke while others remain quiescent. This study aimed to determine if dual-energy CT (DECT) can detect subtle parametric differences in radiologically similar high-risk plaques that may help predict future acute ischemic stroke (AIS) risk.

MATERIALS AND METHODS: This retrospective study enrolled patients with non-stenotic carotid plaques (nsCP), categorized into AIS and non-AIS groups. All patients underwent dual-energy CT angiography. Plaque analysis included conventional parameters-maximum wall thickness (MWT), low-attenuation plaque (LAP, <60 HU) thickness, degree of stenosis, and number of high-risk features (HRF)-as well as spectral parameters derived from DECT, such as virtual monoenergetic image (VMI) attenuation values, Z-effective, spectral curve slope40-140 keV, and iodine concentration. Logistic regression was used to calculate odds ratios (OR), and receiver operating characteristic (ROC) curve analysis was employed to evaluate diagnostic performance.

RESULTS: A total of 87 patients with 216 plaques were analyzed, including 37 AIS patients with 85 plaques. Conventional plaque analysis showed that each additional HRF increased AIS risk by 54%. Similarly, per 1-mm increase in maximum wall thickness and LAP thickness raised AIS risk by 73% and 62%, respectively, while each 1% increase in the degree of stenosis increased risk by 9%. DECT spectral analysis revealed significantly lower attenuation at 140 keV in AIS-group plaques for both napkin-ring sign (22.1 ± 7.8 vs. 29.6 ± 10.4 HU) and LAP (22.2 ± 8.8 vs. 32.3 ± 12.1 HU). ROC analysis demonstrated optimal diagnostic performance at 140 keV for napkin-ring sign (AUC = 0.723) and LAP (AUC = 0.750), with a cutoff of 33.5 HU for low-attenuation plaque, yielding a specificity of 0.952.

CONCLUSION: Subtle differences exist in radiologically similar plaques between AIS and non-AIS patients. DECT parameters can quantify these differences that are beyond conventional imaging morphology. These DECT parameters serve as stroke-associated biomarkers, providing a direction and a foundation for the future development of effective predictive tools and clinical decision-making.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Huang Z, Li S, He J, et al. Beyond Imaging Features: Dual-Energy CT Reveals Subtle Differences in High-Risk Plaques Between Stroke and Non-stroke Patients. Acad Radiol. 2025. PMID: 41318297. doi:10.1016/j.acra.2025.11.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。