文献速递神经儿科影像MR

功能MRI能否可靠替代Wada试验用于儿童患者术前半球语言偏侧化评估:系统综述与荟萃分析

Is functional MRI a reliable surrogate for the Wada test for preoperative assessment of hemispheric language laterality in pediatric patients? A systematic review and meta-analysis.
PubMed 文献 · Neuroradiology · 2025-11-19

该系统综述与荟萃分析检索截至2025年的观察性研究,纳入14篇系统综述、其中8篇共70例患者进入荟萃分析,评估任务态fMRI与颈内动脉阿米妥试验在儿童语言偏侧化评估中的一致性。汇总一致率为81%(95%CI 69%至91%),总体敏感度80%、特异度62%;典型左偏侧化一致率86%(95%CI 68%至97%),非典型偏侧化一致率85%(95%CI 68%至96%)。作者认为任务态fMRI在儿童中结果有前景,但在缺乏强左偏侧化时可能仍需Wada试验确认。

要点

  • 儿童任务态fMRI与Wada试验语言偏侧化汇总一致率81%(95%CI 69%至91%)。
  • 总体敏感度80%、特异度62%,典型左偏侧化一致率86%(95%CI 68%至97%)。
  • 非典型偏侧化一致率85%(95%CI 68%至96%),ROI、范式及判读方法组间无差异。

核心结论

  • 儿童任务态fMRI与Wada试验一致率结果有前景,但任务态fMRI在典型左偏侧化患者中敏感度更高,提示缺乏强左偏侧化时可能仍需Wada试验确认。

研究设计与样本

  • 系统综述与荟萃分析,检索PubMed、Embase、Cochrane和PsycINFO至2025年,纳入报告儿童任务态fMRI与颈内动脉阿米妥试验语言偏侧化一致率的观察性研究;系统综述纳入14篇研究,荟萃分析纳入8篇研究共70例患者。

诊断标准与关键数值

  • 任务态fMRI与颈内动脉阿米妥试验汇总一致率81%(95%CI 69%至91%),总体敏感度80%、特异度62%。
  • 典型偏侧化一致率86%(95%CI 68%至97%),非典型偏侧化一致率85%(95%CI 68%至96%)。
  • 感兴趣区(ROI,p=0.4943)、范式(p=0.3960)和判读方法(p=0.1501)组间无差异。

临床应用与阅片要点

  • 作者认为,儿童任务态fMRI与Wada试验一致率结果有前景,支持将fMRI作为儿童中有价值的工具。
  • 作者认为,任务态fMRI在典型左偏侧化患者中敏感度更高,缺乏强左偏侧化时可能仍需Wada试验确认。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Task-based fMRI (tb-fMRI) has emerged as a promising imaging modality for determination of language lateralization in patients undergoing neurosurgery, largely replacing the invasive gold standard Wada test. However, its applicability in pediatric populations remains uncertain due to the unique characteristics of the developing pediatric brain. This meta-analysis and systematic review aim to synthesize existing data on the concordance rates of tb-fMRI and the intracarotid amobarbital test (IAT) in children undergoing neurosurgery.

METHODS: We systematically searched PubMed, Embase, Cochrane and PsycINFO through 2025 for observational studies reporting concordance rates of tb-fMRI and IAT for language laterality assessment in children.

RESULTS: Fourteen studies were included in the systematic review, of which eight studies with 70 patients met the inclusion criteria in the meta-analysis. The pooled concordance rate between tb-fMRI/IAT was 81% (95% CI: 69% to 91%), with an overall sensitivity of 80% and specificity of 62%. The concordance was 86% (95% CI: 68% to 97%) for typical laterality and 85% (95% CI 68% to 96%) for atypical. There was no difference between groups for region-of-interest (ROI, p = 0.4943), paradigm (p = 0.3960) or interpretation method (p = 0.1501).

CONCLUSION: Concordance rates between tb-fMRI/IAT in pediatric patients show promising results. However, tb-fMRI demonstrates higher sensitivity in patients with typical left-lateralization, suggesting that confirmatory testing with Wada may still be warranted in cases without strong left-lateralization. These findings align with trends observed in the adult population, supporting the use of fMRI as a valuable tool in children.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. de Macedo BA, Verdan S, Joshi DK, et al. Is functional MRI a reliable surrogate for the Wada test for preoperative assessment of hemispheric language laterality in pediatric patients? A systematic review and meta-analysis. Neuroradiology. 2025. PMID: 41258566. doi:10.1007/s00234-025-03841-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。