颅内压增高的新型与经典影像学征象
研究纳入23例疑似颅内压增高患者,在侵入性颅内压测量前进行视神经超声和MRI检查,评估新型蛛网膜主体比值与经典影像征象诊断颅内压增高的准确性。结果显示该比值与颅内压相关性很强(MRI rs=0.89,US rs=0.92),优于视神经鞘直径;MRI上该比值预测颅内压增高的敏感度100%、特异度91%。
要点
- 蛛网膜主体比值在MRI上与颅内压相关性很强(rs=0.89),优于视神经鞘直径(rs=0.67)。
- MRI上该比值预测颅内压增高的敏感度100%、特异度91%。
- 经典征象中横窦狭窄和视神经鞘直径准确度最高,敏感度分别为89%和91%,特异度分别为100%和92%。
核心结论
- 新型蛛网膜主体比值选择性评估神经周围液体间隙,在MRI上能准确预测颅内压,与经典影像征象联合可作为临床有用的无创替代指标。
研究设计与样本
- 前瞻性研究,共纳入23例疑似颅内压增高患者,在侵入性颅内压测量前接受视神经超声和MRI检查,采用ROC曲线分析评估诊断准确性。
关键影像表现/征象
- 颅内压增高者MRI上蛛网膜主体比值和视神经鞘直径分别增大36%和16%(p < 0.001)。
- 颅内压增高者超声上蛛网膜主体比值和视神经鞘直径分别增大39%和13%(p < 0.001)。
- 蛛网膜主体比值与颅内压的相关性在MRI上rs=0.89、超声上rs=0.92,均优于视神经鞘直径(MRI rs=0.67,超声rs=0.63)。
诊断标准与关键数值
- MRI上蛛网膜主体比值预测颅内压增高:敏感度100%,特异度91%。
- 横窦狭窄预测颅内压增高:敏感度89%,特异度100%。
- 视神经鞘直径预测颅内压增高:敏感度91%,特异度92%。
临床应用与阅片要点
- 蛛网膜主体比值可在MRI上作为评估颅内压增高的无创替代指标,与经典影像征象联合使用。
- 横窦狭窄和视神经鞘直径是准确度最高的经典影像征象,阅片时应关注。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The arachnoid bulk ratio was recently described by Berhanu et al. on ultrasonography (US) as a potentially useful surrogate for intracranial pressure (ICP). We aimed to evaluate this novel neuroimaging index using magnetic resonance imaging (MRI) and determine the accuracy of the novel and classic imaging signs to diagnose increased ICP.
METHODS: Patients with suspected increased ICP were recruited to undergo optic nerve US and MRI before invasive ICP measurement. We included a total of 23 participants and determined the correlation of the novel ratio with ICP, compared to the optic nerve sheath diameter (ONSD), and we assessed the diagnostic accuracy of the novel and classic imaging signs through receiver operating characteristic (ROC) curve analysis.
RESULTS: The arachnoid bulk ratio and ONSD were significantly larger in individuals with increased ICP on MRI (36% and 16%,p < 0.001) and on US (39% and 13%,p < 0.001). The ratio correlated very strongly with ICP on MRI and US (rs = 0.89 and rs = 0.92), outperforming the ONSD (MRI:rs = 0.67 and US:rs = 0.63). The Berhanu et al.'s ratio predicted increased ICP with a sensitivity of 100% and a specificity of 91% on MRI. The classic imaging signs with highest accuracy were the transverse sinus stenosis and ONSD, with a sensitivity of 89% and 91% and specificity of 100% and 92%,respectively.
CONCLUSIONS: This novel ratio, which selectively assesses the perineural fluid space, provides an accurate prediction of ICP on MRI. When combined with classic imaging signs, it serves as a useful non-invasive surrogate in the clinical approach to these patients.
引用
- Berhanu D, Martins G, Antunes AP, et al. Novel and classic imaging signs of increased intracranial pressure. Neuroradiology. 2025. PMID: 41174080. doi:10.1007/s00234-025-03815-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。