指南与共识腹部技术与安全CTUS

ACR适用性标准®:急性左上腹疼痛

ACR Appropriateness Criteria® Acute Left Upper Quadrant Pain.
指南 / 共识 · J Am Coll Radiol · 2025-01-01

急性左上腹疼痛临床少见且查体敏感性低,评估困难,可源于脾脏或左上腹感染,也可为胃、肠、胰腺或肾脏的牵涉痛。本ACR适用性标准针对疑似脾肿大、伴发热及未特指的急性左上腹疼痛,采用GRADE与RAND/UCLA适用性方法系统分析文献,给出影像检查推荐。

要点

  • 急性左上腹疼痛查体一致性最低、敏感性有限,影像评估具有重要价值。
  • 疑似脾肿大患者,腹部超声与增强CT腹盆腔均可作为初始影像检查的适用选择。
  • 伴发热或未特指的急性左上腹疼痛,增强CT腹盆腔通常适用于检测多种病变。

核心结论

  • 增强CT腹盆腔通常适用于检测急性左上腹疼痛相关的广泛病变。
  • 疑似脾肿大患者,腹部超声也是初始影像检查通常适用的替代选择。

研究设计与样本

  • 美国放射学会(ACR)适用性标准,针对特定临床情况制定,由多学科专家小组每年审阅。
  • 指南制定与修订过程系统分析同行评议期刊的医学文献,采用GRADE等既定方法学原则评估证据。
  • 采用RAND/UCLA适用性方法用户手册确定特定临床场景下影像与治疗程序的适用性。
  • 同行评议文献缺乏或模棱两可时,专家可作为形成推荐的主要证据来源。

诊断标准与关键数值

  • 增强CT腹盆腔:通常适用于急性左上腹疼痛的初始影像评估。
  • 腹部超声:疑似脾肿大患者初始影像评估通常适用的替代选择。

临床应用与阅片要点

  • 临床场景分为疑似脾肿大、伴发热和未特指三类,据此选择初始影像检查。
  • 急性左上腹疼痛可为左上腹器官病变或胃、肠、胰腺、肾脏的牵涉痛,读片需结合临床定位。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Acute abdominal pain is one of the most common chief complaints encountered in the emergency department and outpatient setting. Across all sites, the left upper quadrant (LUQ) is the least common location for abdominal pain with reportedly the lowest physical examination interrater agreement. The limited sensitivity of physical examination, combined with an uncommon and nonspecific clinical presentation, make assessment of LUQ pain challenging. Acute LUQ pain may arise directly from the spleen or infections in the LUQ, or represent referred pain from other organs such as stomach, bowels, pancreas, or kidney. This document aims to address acute pain with suspected splenomegaly, with fever, and not otherwise specified. CT abdomen and pelvis with contrast is usually appropriate for detection of a broad range of pathologies. In patients with suspected splenomegaly, ultrasound abdomen is also usually an appropriate alternate for initial imaging. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Soleimani S, Kamel IR, Chang KJ, et al. ACR Appropriateness Criteria® Acute Left Upper Quadrant Pain. J Am Coll Radiol. 2025. PMID: 41193039. doi:10.1016/j.jacr.2025.08.046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。