文献速递神经MR

基于Transformer的CNN在三维FLAIR MRI上分割多发性硬化病灶的多中心研究

A multi-center study of transformer-based CNNs for multiple sclerosis lesion segmentation on 3D FLAIR MRI.
PubMed 文献 · Neuroradiology · 2025-10-14

本研究开发并评估了一种Transformer-CNN框架,用于在FLAIR MRI上自动分割多发性硬化病灶,并与U-Net和DeepLabV3进行基准比较。在来自五个临床中心的1800例3D FLAIR MRI扫描上采用内部5折交叉验证,Transformer-CNN取得最佳分割精度和跨中心性能(Dice 92.3%,HD95 2.25 mm)。

要点

  • Transformer-CNN在MS病灶分割中Dice达92.3%,优于DeepLabV3(85.1%)和U-Net(83.0%)。
  • 跨中心性能指标GDSC 91.3%、DwIoU 89.2%、CFDD 1.05%、ICC 96.5%均为最优。
  • U-Net表现最差,跨数据集变异性高且对小病灶检测困难。

核心结论

  • 在内部5折交叉验证下,Transformer-CNN在分割精度和跨中心性能上均优于U-Net和DeepLabV3,其稳健性、低变异性及跨多样数据集泛化能力使其成为临床MS病灶分割与监测的实用可靠工具。

研究设计与样本

  • 多中心研究,数据集为来自五个临床中心的1800例3D FLAIR MRI扫描,采用5折交叉验证拆分,预处理包括各向同性重采样、强度归一化和偏场校正。

诊断标准与关键数值

  • Transformer-CNN的Dice评分92.3%、IoU 91.4%、HD95 2.25 mm、像素准确率95.6%;GDSC 91.3%、DwIoU 89.2%、CFDD 1.05%、ICC 96.5%;DeepLabV3的Dice为85.1%、HD95为4.15 mm;U-Net的Dice为83.0%、HD95为4.30 mm。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to develop and evaluate a Transformer-CNN framework for automated segmentation of multiple sclerosis (MS) lesions on FLAIR MRI. The model was benchmarked against U-Net and DeepLabV3 and assessed for both segmentation accuracy and across-center performance under internal 5-fold cross-validation to ensure robustness across diverse clinical datasets.

MATERIALS AND METHODS: A dataset of 1,800 3D FLAIR MRI scans from five clinical centers was split using 5-fold cross-validation. Preprocessing included isotropic resampling, intensity normalization, and bias field correction. The Transformer-CNN combined CNN-based local feature extraction with Transformer-based global context modeling. Data augmentation strategies, including geometric transformations and noise injection, enhanced generalization. Performance was evaluated using Dice score, IoU, HD95, and pixel accuracy, along with internal cross-validation-based metrics such as Generalized Dice Similarity Coefficient (GDSC), Domain-wise IoU (DwIoU), Cross-Fold Dice Deviation (CFDD), and Volume Agreement (Intraclass Correlation Coefficient, ICC). Statistical significance was tested using Kruskal-Wallis and Dunn's post-hoc analyses to compare models.

RESULTS: The Transformer-CNN achieved the best overall performance, with a Dice score of 92.3%, IoU of 91.4%, HD95 of 2.25 mm, and pixel accuracy of 95.6%. It also excelled in internal cross-validation-based across-center metrics, achieving the highest GDSC (91.3%) and DwIoU (89.2%), the lowest CFDD (1.05%), and the highest ICC (96.5%). DeepLabV3 and U-Net scored 85.1% and 83.0% in Dice, with HD95 values of 4.15 mm and 4.30 mm, respectively. The worst performance was observed in U-Net, which exhibited high variability across datasets and struggled with small lesion detection.

CONCLUSIONS: The Transformer-CNN outperformed U-Net and DeepLabV3 in segmentation accuracy and across-center performance under internal 5-fold cross-validation. Its robustness, minimal variability, and ability to generalize across diverse datasets establish it as a practical and reliable tool for clinical MS lesion segmentation and monitoring.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Saadh MJ, Khidr WA, Albadr RJ, et al. A multi-center study of transformer-based CNNs for multiple sclerosis lesion segmentation on 3D FLAIR MRI. Neuroradiology. 2025. PMID: 41085708. doi:10.1007/s00234-025-03802-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。