辐射暴露与血管阻力、动脉重塑及动脉粥样硬化指标的关系
这项回顾性队列分析纳入806例原子弹幸存者,按辐射剂量分为<0.3 Gy、0.3-3 Gy和>3 Gy三组,采用颈动脉超声评估颈总动脉直径、阻力指数和斑块形成。多因素分析显示,>3 Gy组颈总动脉直径增大和阻力指数升高的风险显著高于<0.3 Gy组,而斑块数量和最大斑块厚度在3组间无显著差异。结论提示辐射暴露可能影响血管阻力和重塑。
要点
- 辐射剂量>3 Gy组颈总动脉直径增大风险显著高于<0.3 Gy组(OR 4.36)。
- 辐射剂量>3 Gy组颈总动脉阻力指数升高风险显著高于<0.3 Gy组(OR 4.04)。
- 斑块数量和最大斑块厚度在3个辐射剂量组间无显著差异。
核心结论
- 辐射暴露可能影响血管阻力和重塑;为评估辐射暴露个体的心血管疾病风险,似乎有必要研究动脉粥样硬化以外的血管损伤效应。
研究设计与样本
- 回顾性队列分析,纳入806例原子弹幸存者,辐射剂量来自广岛原子弹幸存者研究数据库,2003年4月至2021年12月期间接受颈动脉超声检查,按辐射剂量分为<0.3 Gy、0.3-3 Gy和>3 Gy三组。
关键影像表现/征象
- 颈总动脉直径增大(最高四分位)在<0.3 Gy组和>3 Gy组的比例分别为24.2%和50.0%。
- 高阻力指数(最高四分位)在<0.3 Gy组和>3 Gy组的比例分别为23.5%和54.6%。
诊断标准与关键数值
- 各指标最高四分位分别定义为颈总动脉直径增大、高阻力指数、斑块数量增多和最大斑块厚度增大。
- 多因素分析中,>3 Gy组较<0.3 Gy组颈总动脉直径增大的OR为4.36(95%CI 1.30-14.7)。
- 多因素分析中,>3 Gy组较<0.3 Gy组高阻力指数的OR为4.04(95%CI 1.14-14.3)。
- 斑块数量或最大斑块厚度在3个辐射剂量组间无显著差异。
临床应用与阅片要点
- 在辐射暴露人群的颈动脉超声评估中,除斑块数量和厚度外,可关注颈总动脉直径和阻力指数等血管重塑与阻力指标。
- 作者认为,为评估辐射暴露个体的心血管疾病风险,似乎有必要研究动脉粥样硬化以外的血管损伤效应。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The diameter, resistance index (RI), and plaque formation in the common carotid artery (CCA) are indicators of arterial remodelling, vascular resistance, and atherosclerosis, respectively. This study used CCA parameters to investigate the longitudinal relationship between radiation exposure and vascular damage.
METHODS: This retrospective cohort analysis included 806 atomic bomb survivors with estimated radiation doses from the Hiroshima atomic bomb survivor study database, who underwent carotid artery ultrasonography between April 2003 and December 2021. Participants were divided into 3 groups based on their radiation doses: <0.3 Gy, 0.3-3 Gy, and >3 Gy. The highest quartile of each index was defined as having a large CCA diameter, a high RI, increased plaque number, and a greater maximum plaque thickness.
RESULTS: The median time between radiation exposure and carotid artery ultrasonography was 68.3 years. In the <0.3 and >3 Gy groups, the proportions of large CCA diameter were 24.2% and 50.0%, and the proportions of high RI were 23.5% and 54.6%, respectively. In multivariate analysis, the >3 Gy group had significantly larger CCA diameter (odds ratio [OR]: 4.36, 95% confidence interval [CI], 1.30-14.7) and higher RI (OR: 4.04, 95% CI, 1.14-14.3) than the <0.3 Gy group. The plaque number or maximum plaque thickness did not differ significantly among the 3-radiation dose groups.
CONCLUSIONS: Radiation exposure may affect vascular resistance and remodelling.
ADVANCES IN KNOWLEDGE: To assess the risk of cardiovascular disease in radiation-exposed individuals, it appears necessary to investigate the effects of vascular damage other than atherosclerosis.
引用
- Sasaki N, Ueno Y, Hirota S, et al. Relationship between radiation exposure and indicators of vascular resistance, arterial remodeling, and atherosclerosis. Br J Radiol. 2026. PMID: 41075161. doi:10.1093/bjr/tqaf252
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。